4
Cooper Lighting Solutions
IB516115EN
Installation Instructions
Installation Instructions – ClearPath Bollard
Step 7
Make the electrical connections.
See diagram for proper wiring. Use UL wet location rated
connectors. The ground shown going to the fixture requires
2 connections. Connect a lead to the mounting base with
the green, self-tapping, ground screw provided. Torque
the ground screw to 5 in-lbs. The luminaire ground wire
also needs to be connected to the earth ground from the
foundation. (Figure 6 & 6a.)
Neutral
Inst
allation Site F
oundation
Fixt
ure
Leads
Fixt
ure Mounting B
ase
White
Black
Green
Line Voltage
Ground
Figure 6. Field Wiring Diagram
Figure 5a. Even Gap Between Brackets & Bosses In
Housing
Figure 5b. Uneven Gap Between Brackets & Bosses In
Housing
Step 6
Tighten the mounting brackets.
Adjust the mounting brackets such that both feet of each
bracket are close to equally spaced from the housing.
Examples of good and poor installations are shown. Torque
the socket head cap screws to 5 ft-lbs. Check for plumb.
Check that the bracket feet are still roughly the same
distance from the housing. Loosen and restart step 5 if
necessary. Final torque the socket head cap screws to