INSTALLATION

A. Install ELPS502 System or ELPS50 Power Supply

1. Select mounting location that will provide suitable strength and rigidity for supporting

power supply and attached lighting fixtures. Figure 1 shows the overall dimensions
and mounting dimensions for the four mounting feet.

Weights:

ELPS502 System

50 lbs.

ELPS502 EXS/EXD System 

60 lbs.

ELPS50 Power Supply 

40 lbs.

EVLA12 Fixture 

5 lbs.

2. Securely fasten enclosure to the mounting location using 3/8" diameter bolts or

screws.

3. Remove the cover bolts and nuts from two stud bolts, then lift off cover and carefully

set it aside to prevent damage to the flat joint and flange gasket. 

NOTE

: ELPS units have two stud bolts located at diagonally opposite corners of the

body to aid in positioning cover. Do not remove stud bolts.

4. Proceed to Section B to attach and/or adjust EVLA lighting fixtures.

B. Attach and Adjust EVLA12 Lighting Fixture(s)

NOTE:

If installing ELPS502, fixtures are already attached. Proceed to Step 5 to

adjust fixtures.

1. Remove pipe plug(s) from the 1" NPT tapped holes in the side(s) of the ELPS50

power supply enclosure where the EVLA12 fixture is to be installed.

NOTE:

Remotely mounted EVLA fixtures can be mounted in a suitable splice box,

such as Crouse-Hinds EABT36, EABL36, or EABC36 that provides a 1" hub for
fixture attachment.

2. Thread light assembly into body being sure that the reducer fitting is engaged with the

body at least five full threads.

3. Using a 1-5/8” wrench, loosen Nut ‘A’, position lamp head in desired vertical position

and retighten to 58 lb.-ft. torque.

4. Using the same 1-5/8” wrench, loosen Nut ‘B’ and position lamp head in desired

horizontal position.  Be sure to re-tighten Nut ‘B’ to 58 lb.-ft. torque.

Figure 2.  EVLA Lighting Fixture

IF 1510  •  05/06

Copyright © 2006, Cooper Industries, Inc.

Page 2

IMPORTANT

The recommended mounting position is with the back wall of the enclosure
fastened to a vertical surface with the pilot light and push-to-test push button
located on the bottom of the enclosure.

IMPORTANT

Spacers are required between splice box and mounting surface to ensure
proper clearance for fixture hub rotation during installation. 1

1

/

8

” dimension is

required between center line of mounting hub & face of mounting surface.

WARNING

To avoid electrical shock, electrical power must be turned OFF before and during installation and maintenance.

CAUTION

To avoid damaging the flat joint surfaces, do not use hammers or prying tools to
open covers. Do not handle covers roughly, or place them on surfaces that might
damage or scratch the flat joint surfaces.

NOTE

A Class I, Division 1 sealing fitting must be installed within 18 inches of the
conduit entry of the ELPS enclosure.  Use Chico A  or Chico SpeedSeal sealing
compound to seal the conduit entry.

CAUTION

EVLA fixture head and arm are limited to no more than 180º of rotational
adjustment.  Failure to adhere to this will result in damage to the internal wiring.

Figure 1.  ELPS502 and ELPS502 EXS / EXD Dimensions

11.00

11.13

12.81

16.50

29.63

14.75

6.50

1.13  EXS/EXD

2.13 EXD GB

7.00  EXS/EXD

8.38 EXD GB

33.00 EXS/EXD

35.63 EXD GB

30.00  EXS/EXD

30.63 EXD GB

Nut ‘A’

Nut ‘B’

Содержание ELPS50

Страница 1: ...included with all fixtures The EVLA12 is suitable for NEMA 4X locations when remote mounted not installed on an ELPS Power Supply and supplied with a NEMA 4X breather drain NOTE Ambient temperature at...

Страница 2: ...sen Nut A position lamp head in desired vertical position and retighten to 58 lb ft torque 4 Using the same 1 5 8 wrench loosen Nut B and position lamp head in desired horizontal position Be sure to r...

Страница 3: ...VAC primary through designated disconnect to terminal 120 3 Connect 220 240 VAC primary through designated disconnect to terminal 220 240 4 Connect 277 VAC primary through designated disconnect to te...

Страница 4: ...tates that Systems shall be tested periodically on a schedule acceptable to the authority having jurisdiction to assure their maintenance in proper operating condition It also states that A written re...

Страница 5: ...stall lens ring by turning clockwise until threads are fully engaged All screw threads have been treated with a corrosion resistant lubricant Whenever disturbing threaded joints relubricate the thread...

Страница 6: ...GRD 1 through L 7 6 Remove the mounting stud and pillar located in the uppermost left corner of the interior Remove the three other hold down nuts and lock washers on the aluminum backplate Remove the...

Страница 7: ...ch and observe Main Power ON light should be OFF and the EVLA12 emergency light s should be ON 6 Lock the Designated disconnect switch ON to prevent unauthorized persons from turning system OFF 7 Cond...

Страница 8: ...LATION AND MAINTENANCE INSTRUCTION SHEETS FOR METHODS OF TESTING All statements technical information and recommendations contained herein are based on information and tests we believe to be reliable...

Страница 9: ...ts de normes NEMA 4X lorsque install distance n utilise pas un bloc d alimentation ELPS et fourni avec un reniflard purge REMARQUE pour maximiser la dur e de fonctionnement du bloc d alimentation ELPS...

Страница 10: ...8 po desserrer l crou A positionner la t te du luminaire dans la position verticale voulue et resserrer l crou un couple de 58 lb pi 4 Utiliser la m me cl de 1 5 8 po desserrer l crou B et positionne...

Страница 11: ...ivre le c blage de l alimentation EDS2129 EDS2129GB pour les applications de groupe B interrupteur sectionneur d sign pour installation distance non fourni Installer selon les directives fournies avec...

Страница 12: ...s devraient tre test s r guli rement selon un programme acceptable par les autorit s qui ont juridiction pour assurer un bon tat de fonctionnement continuel Elle pr cise galement qu un registre par cr...

Страница 13: ...de la lentille La tourner dans le sens horaire pour visser compl tement tout le filetage Tous les filets de la vis ont t enduits d un lubrifiant r sistant la corrosion D s qu un joint filet est manipu...

Страница 14: ...n 3 Apr s avoir coup toutes les sources d alimentation du luminaire retirer toutes les attaches du couvercle pour acc der aux l ments internes 4 D brancher les fils de la lampe t moin et de l interrup...

Страница 15: ...t moin Main Power ON alimentation principale pr sente devrait tre TEINTE et l clairage de s curit EVLA12 devrait FONCTIONNER 6 Verrouiller l interrupteur sectionneur d sign en position ON marche pour...

Страница 16: ...DE DIRECTIVES D INSTALLATION ET D ENTRETIEN POUR CONNA TRE LES M THODES D ESSAI Toutes les d clarations tous les renseignements techniques et toutes les recommandations dans les pr sentes sont bas s...

Страница 17: ...cesorios incluyen l mparas El EVLA12 est dise ado para reas NEMA 4X cuando se monta remotamente no se instala sobre una fuente de alimentaci n ELPS y se suministra con un respiradero drenaje NEMA 4X N...

Страница 18: ...a llave de 1 5 8 afloje la Tuerca A coloque la cabeza de la l mpara en la posici n vertical deseada y apriete a 58 lb ft de torque 4 Con la misma llave de 1 5 8 afloje la Tuerca B y coloque la cabeza...

Страница 19: ...GB para aplicaciones Grupo B Interruptor con montaje remoto no suministrado Instale seg n las instrucciones suministradas con el interruptor EDS2129 GB Realice el cableado a los terminales 8 y 9 Vea e...

Страница 20: ...dicamente seg n un cronograma aceptable para las autoridades con jurisdicci n para garantizar su mantenimiento en condiciones de operaci n adecuadas Tambi n indica que se debe mantener un registro es...

Страница 21: ...en Halogen G4 2 pins 14 watts 6 Instale el anillo de la lente girando en el sentido de las agujas del reloj hasta enroscarlo por completo Todas las cuerdas de los tornillos fueron tratadas con un lubr...

Страница 22: ...tapa para acceder al interior 4 Desconecte las puntas de los cables en la l mpara piloto y el interruptor 5 Desconecte todas las conexiones entrantes de los terminales GRD 1 a L 7 6 Retire el perno de...

Страница 23: ...r an estar encendidas 6 Configure el interruptor de desconexi n designado en ON para evitar que personas no autorizadas apaguen el sistema 7 Realice pruebas peri dicas de acuerdo con el Manual de Inst...

Страница 24: ...EEMPLAZO DE L MPARA NOTAS HORA BATER A POR INDICAR UBICACI N DEL ACCESORIO DURACI N DE LA PRUEBA REGISTRO DE MANTENIMIENTO REQUISITOS NFPA 101 2003 SE DEBE REALIZAR UNA PRUEBA FUNCIONAL SOBRE TODOS LO...