Introduction

 

Voice Alarm (VA) systems are the quickest way to evacuate the public & staff from a building. 

Following fire detection, automated messages control the flow of people in stairwells and corridors 

allowing an orderly evacuation without panic. These messages are supplemented by spoken messages 

from the fire service or management suite confirming the validity and need to leave the building. 

This positive confirmation speeds evacuation and avoids the "false alarm" mentality reducing the risk of 

death from fire. 

 

 CFDAU30 is a new Voice alarm system from Cooper Fire 

An innovation which combines the Cooper analogue addressable Fire detection and alarm functionality 

with very sophisticated cause and effect program with the latest voice alarm address technology. 

 

Up to 20 CFDAU30 per loop with build in amplifier can be connected to any Cooper addressable Fire 

Panel. 

CFDAU30 has build in isolator and can be hard or soft addressed by the Cooper addressable panels 

 

The CFDAU30 delivers clear, intelligible voice alarm messages which ensures reliable and constant life 

safety protection for both people and property. 

It is well documented that only 13% of people react to bells, whilst 70% react to a voice message. 

 

Suitability 

Voice Alarm systems are recommended for all public buildings and multi story buildings over four floors 

by BS5588. 

In public buildings it's not possible to fire drill the public, as they visit the premises infrequently, so 

systems such as Voice alarms save valuable time in evacuating the building. 

The use of phased messages in multi-story buildings prevents over-crowding in stairwells and at exits, 

preventing secondary injuries. In phased evacuation, the floor in fire receives the evacuate message, 

and the floor above & below receive an alert message, preparing them for evacuation.  

In more complex scenarios the use of multiple alert and evacuate messages can be beneficial, essages 

telling the evacuees they are going the right way, and messages asking people to make way for people 

leaving evacuated areas. These additional messages can dramatically speed up the evacuation 

especially in malls and large airport environments. 

Product Overview 

Cooper has been developed a VA system to replace talking sounders in many voice alarm applications, 

and is available in several forms. The CFDAU30 is a complete VA system in a single wall mount box 

which is complete with messages, fire interface, dual 30W monitored amplifiers, power supply, 

monitored battery charger and the ability to connect non monitored paging and music directly. Up to 20 

CFDAU30 per loop with build in amplifier can be connected to any Cooper addressable Fire Panel. 

CFDAU30 has build in isolator and can be hard or soft addressed by the Cooper addressable panels 

 

Содержание CFDAU30

Страница 1: ...CFDAU30 Voice Alarm System Installation and Maintenance Manual Cooper Lighting and Safety Ltd Wheatley Hall Road Doncaster South Yorkshire DN2 4NB TEL 44 0 1302 321541 FAX 44 0 1302 303220...

Страница 2: ...ommended for all public buildings and multi story buildings over four floors by BS5588 In public buildings it s not possible to fire drill the public as they visit the premises infrequently so systems...

Страница 3: ...e system designed to be used by the controlling officer 2 Message Generator this has three messages all messages latch until reset from either the front panel recessed button or from the cancel button...

Страница 4: ...s follows Weekly Broadcast the test message to all zones and check speaker operation microphones should be checked for operation if fitted record results in the site log Monthly Trigger the fire alarm...

Страница 5: ...e is playing Green for test Yellow for the Alert Message and RED for the Evacuate message Paging Lights green when the paging microphone is in use Music Lights green when the music channel is open no...

Страница 6: ...nits are distributed around a site it is essential all units are on the same mains phase as they are classified TEN 230V powering from different phases can mean a 440V potential can be present in a un...

Страница 7: ...line Resistors e Crimped Battery Link Lead f Black jumper header to Enable Fire Microphone Monitoring Using the HEX key supplied remove the front cover Verify the following items are present 1 2 off...

Страница 8: ...ved fill the hole with a good quality cable gland 18 knockouts are provided 8 on the top face from left to right Speaker Network A Speaker Network B Fault Fire alarm Interface Fire Microphone connecti...

Страница 9: ...ed for the fire alarm interface loudspeakers fireman s microphone paging background music equipment and slave amplifiers please refer to the relevant sections later in this manual Note that correct ca...

Страница 10: ...and 1 hour operation 2 number 12V 17AH batteries are required these will need to be fitted in an external battery enclosure the monitored charger in the Cooper CFDAU30 is capable of charging and monit...

Страница 11: ...le speakers for CFDAU30 MUST have a thermal fuse to disconnect the speaker if it is in the area in fire and a DC blocking capacitor fitted typically the capacitor is 2 2uF 250V DC The wiring goes thro...

Страница 12: ...ction point see earlier in this manual preferred types are screened soft skin cables such as FP200 although MICC can be used Cable Length Chart The following table shows the maximum cable run to achie...

Страница 13: ...the top on the Cooper CFDAU30 the Au pin is at the bottom of the block The CFDAU30 is shipped as standard with the monitoring of the Fire Microphone DISABLED to enable the monitoring fit the jumper su...

Страница 14: ...n isolator and can be hard or soft addressed by the Cooper addressable panels CFDAU30 is fully monitored and controlled by any Cooper Fire addressable Fire Panels NOTE MESSAGES WILL ALWAYS PLAY TO THE...

Страница 15: ...messages can be independently adjusted using the front panel recessed control marked MESSAGES the messages Override paging and music when operated the level of the individual messages can be altered...

Страница 16: ...limiter to prevent clipping of the CFDAU30 and corrects for poor microphone technique The UNDM1 provides busy indication and first come first served logic for cascading microphones Microphone connect...

Страница 17: ...ted when mains fails in line with BS5839pt8 to preserve battery life The level of the paging microphone can be independently adjusted using the front panel recessed control marked MUSIC NOTE If music...

Страница 18: ...E Sensitivity 6dBV to 4dBV Ptt Type 5V to access Power 24V nominal 100mA self resetting fuse Fire Interface Inputs 3 off isolated 12V to 33V Alert Evacuate Reset Outputs 1 Relay open on fault 30V 1A M...

Отзывы: