Cooper Power Systems Kyle Type ME Series Скачать руководство пользователя страница 40

Catalog No.

Description

KA1037ME6S

Instantaneous Trip—Phase and Ground. Phase

Multiple of 1.4, 2.0, 2.8, 4.0 or 5.6; Ground
Multiple of S.6, 8.0, 11.2, 16.0, or 22.4

KA1037ME7S

Instantaneous Trip—Phase and Ground, Phase

Multiple of 5.6, 8.0, 11.2, 16.0, or 22.4: Ground
Multiple of 1.4, 2.0, 2.8, 4.0, or 5.6

KA1037ME8S

Instantaneous Trip—Phase and Ground, Both

With Multiples of 5.6, 8.0, 11.2, 16.0, or 22.4

KA1102ME1

Standard Input Plug Board and Harness for

Form 3A

KA1103ME

Tie Board, Form 3A

KA1109ME8

Standard Charger Board—120-Vac, F3A Only

KA1109ME9

Standard Charger Board—240-Vac, F3A Only

KA1134ME1S

Automatic Resetting Fault Indicator Circuit Board

KA1137ME1S

Annunciator—Type Target Accessory—Auto

Reset, Phase only; Above 14450

KA1137ME2S

Annunciator—Type Target Accessory—Auto

Reset, Phase and Ground; Above 14450

KA1141ME1

Selector Switch and Wire Pistol Grip, Form 3A

only

KA1142ME3

Shelf Battery Charger, Portable

KA1159ME

Ground Trip Sequence Selector Switch—Form

3A only

KA1160ME

Operations to Lockout Sequence Switch—Al1

Controls

KA1163MES

Minimum Response Time

KA1174ME1S

Temperature Regulated Battery Charger Accy.—

120-Vac, for F3A 26000 and Above

KA1174ME2S

Temperature Regulated Battery Charger Accy.—

240-Vac, for F3A 26000 and Above

KA1193ME

Harness only for Standard Input Plug Board

for F3A

KA1194ME1

Standard Input Plug Board only for Form 3A

KA2003MES

Remote Close With Cold-Load Pickup

KA2035ME2S

Remote Non-Reclose and Ground Trip Block—

Maintained Contact, 24V

KA2039ME1S

Recloser Status—Without Indicator Lamps

KA2039ME2S

Recloser Status—With Indicator Lamps

KA2047MES

Battery Monitor—over 30-Vdc/Under 22-Vdc

Indication

KA2070ME1S

Remote Close With Cold Load Pickup Remote

Lockout and Status—Without Indicator Lamps

KA2070ME2S

Remote Close With Cold Load Pickup Remote

Lockout and Status—With Indicator Lamps

KA2071ME1S

Remote Non-Reclose and Ground Trip Block—

Pulse Contact, 24V

KA2072MES

Battery Monitor—Analog

KA2189MES

Remote Indication of Fault Target Accessory

KP457ME

Mounting Strip (Conducting)

KP483ME1

Trip Resistor Clamps

KP509ME

Mounting Strip Insulating

KP674ME1

Sequence Relay—for Form 3 and 3A

KP884ME

Circuit Board Shield

KP894ME1

Battery Mounting Bracket, Form 3 and 3A

KP953ME

Panel Locking Spring

KP1077ME1S

Cover

KP1100ME

Fuse Block Single Section

KP1110ME

Fuse Block End Closure Unit

KP1139ME1

Flip Disc Target—Complete

KP2069A4

Knob for Number of operations Selector

Switches (Ground, Phase or Lockout)

KP2069A8

Manual Control Switch Handle

KP2075A2

2 Amp Fuse—Type AGC, Glass Tube; Min.

Qty. 5

KP2075A4

3/4 Amp Fuse, Type AGX

KP2075A13

15 Amp Fuse—Type BAN, Fibre Tube; Min.

Qty. 5

KP2075A18

3/8 Amp Fuse, Slow Blow Type MDQ, Min. Qty. 5

KP2075A19

6 Amp Fuse, Type BAN

KP2080A1S

Plastic Battery Connector—Male, Battery

Connechon

KP2080A2S

Plastic Battery Connector—Female, Control

Connection

KP4060A12

120 Volt Relay, 2 to 60 Sec.

KP4060A22

28 Volt Relay, 2 to 60 Sec.

KP4061A3

28 Volt Relay, 0.15 to 1.0 Sec.

K721525105018A

Screw—for Trip Resistors Clamps

K999904310283A

Bulb—24V, for Lockout Indicator

Type ME Electronic Recloser Control

40

TABLE 17
Type ME Control Replacement Parts Acessories
Form 2 (Above S/N 1900), Form 3  (Above S/N 4000), Form 3A (Above S/N 26000) (continued)

Catalog No.

Description

KA716ME

Reclosing Fuse Replacement Kit

KA719ME

120-Vac Surge Protection Field Kit

KA720ME

240-Vac Surge Protection Field Kit

KA721ME

Battery Post Installation Kit, 4000 and Above

KA734ME1

48-Vdc Supply Adapter (AEP only 15 Amp)

KA734ME2

125-Vdc Supply Adapter (AEP only 5 Amp)

KA734ME3

125-Vdc Supply Adapter (AEP only 5 Amp)

KA734ME4

48-Vdc Supply Adapter (15 Amp) from 5501 Thru

25999

KA734ME5

125-Vdc Supply Adapter (15 Amp) from 5501

Thru 25999

KA734ME6

125-Vdc Supply Adapter (15 Amp) from 5501

Thru 25999

KA734ME10

48-Vdc Supply Adapter (15 Amp) 26000 and

Above

KA734ME11

125-Vdc Supply Adapter (5 Amp) 26000 and

Above

KA734ME12

125-Vdc Supply Adapter (15 Amp) 26000 and

Above

KA734ME13

48-Vdc Field Kit for DC Supply—15A 240-Vac

F3A

KA734ME14

125-Vdc Field Kit for DC Supply—5A 240-Vac

F3A

KA734ME15

125-Vdc Field Kit for DC Supply—15A 240-Vac

F3A

KA735ME

Battery Bracket Mounting Kit for GE Batteries in

Controls Below 15000

KA736ME

Conversion Kit to Cold Load Pickup from Form 3

to Form 3A

KA741 ME4

Retrofit Kit for Replacing Demand Meters—With

Instantaneous Indicating Elements Below
35909

KA741 ME5

Retrofit Kit for Replacing Demand Meters—

Without Instantaneous Indicating Elements,
Below 35909

KA746ME

Battery—24V, for Form 2

KA835ME901

Phase Trip Sequence Selector Switch

KA835ME902

Phase Trip Sequence Selector Switch—for Use

With Sequence Coodination Accessory

KA852ME2S

Standard Heater—240V

KA871ME2

Battery Charging Isolation Transformer

KA1000ME1S

Minimum Trip Doubler—Local Operation—

Phase only

KA1000ME2S

Minimum Trip Doubler—Local Operation—

Phase and Ground

KA1002ME4S

Minimum Trip Doubler—Remotely operated

KA1002ME5S

Minimum Trip Doubler—Three Wire Control to

Double Return

KA1004MES

Remote Trip Accessory Kit

KA1021 ME4

Protective Accessory Field Kit for Ground Trip—

4000 to 50071, Supersedes KA921 ME4

KA1021 ME5

Protective Accessory Field Kit for Phase Trip—

4000 to 50071, Supersedes KA921 ME5

KA1021 ME6

Protective Accessory Field Kit for Phase and

Ground Trip—4000 to 50071, Supersedes
KA921 ME6

KA1030ME2S

Fault Indicator—Counter Type Phase and

Ground, Above 14450

KA1036ME1S

Instantaneous Lockout—Phase only, Multiple

of 1.4, 2.0, 2.8, 4.0, or 5.6

KA1036ME2S

Instantaneous Lockout—Phase Only, Multiple

of 5.6, 8.0 11.2 16.0 or 22.4

KA1036ME5S

Instantaneous Lockout—Phase and Ground,

Both With Multiples of 1.4, 2.0, 2.8, 4.0, or 5.6

KA1036ME6S

Instantaneous Lockout—Phase and Ground,

Phase Multiple of 1.4, 2.0, 2.8, 4.0 or 5.6;
Ground Multiple of 5.6, 8.0, 11.2, 16.0, or 22.4

KA1036ME7S

Instantaneous Lockout—Phase and Ground

Phase Multiple of 5.6, 8.0, 11.2 1 6.0 or 22.4
Ground Multiple of 1.4, 2 0, 2.8, 4.0 or 5.6

KA1036ME8S

Instantaneous Lockout—Phase and Ground,

Both With Multiples of 5.6, 8.0, 11.2, 16.0, or
22.4

KA1037ME1S

Instantaneous Trip—Phase only, Multiples

of 1.4, 2.0, 2.8, 4.0 or 5.6

KA1037ME2S

Instantaneous Trip—Phase only, Multiples

of 5.6, 8.0, 11.2 16.0, or 22.4

KA1037ME5S

Instantaneous Tr;p—Phase and Ground, Both

With Multiples of 1.4, 2.0, 2.8, 4.0 or 5.6

Содержание Kyle Type ME Series

Страница 1: ...e Trip No 2 Board 11 Ground Trip No 1 and No 2 Boards 11 Output Board 12 Diode Board 12 Recloser Reset Board 12 Closing Coil Control Fuse 12 Interchangeability of Boards Between Form 2 Form 3 and Form...

Страница 2: ...tage lines and equipment and support our Safety For Life mission SAFETY FOR LIFE SAFETY FOR LIFE This manual may contain four types of hazard statements DANGER Indicates an imminently haz ardous situa...

Страница 3: ...l standard operating and programming features is explained The factory service department offers maintenance training courses for Type ME controls These classes taught by ex perienced service technici...

Страница 4: ...sensed by three internally mounted bushing current transformers one on each phase When the phase current or the zero sequence ground current exceeds its programmed minimum trip value the electronic c...

Страница 5: ...urrent that exceeds the minimum trip level of the control Permanent Fault Any over current condition that per sists through the operating sequence of the control Temporary Fault Any over current condi...

Страница 6: ...iming will be erased Ground fault sensing and tripping operations occur exactly the same as phase fault sensing and tripping except that zero sequence ground current is sensed instead of phase current...

Страница 7: ...manual The left hand pair of terminals V are connected directly across the battery output to check battery voltage The red terminal far left is positive The output voltage of a fully charged battery...

Страница 8: ...manuals listed in Appendix lll of this manual 10 Return control to service A Check battery to ensure that it is properly connected B Move Manual Control Switch to match position of reclos er open or...

Страница 9: ...converts the ac input signal from three phase to a single do signal The do signal is applied to the phase trip No 2 board which measures the do level and determines whether a fault current exists at...

Страница 10: ...ery charging board The battery charging board converts the input to dc and supplies charging current to the control battery on Form 3 controls the battery is charged by bushing current transformers on...

Страница 11: ...cuits for minimum trip and the wave shaping circuits for the timing plugs There are two tabs on the phase trip No 2 board for the Form 3 and 3A control one tab is labeled minimum trip MIN TRIP and is...

Страница 12: ...only Buss Type MDQ 3 8 amp fuses Previously all Form 3A and most earlier con trols were supplied with Buss Type MDL 3 8 amp fuses Buss has redesigned and changed the characteristics of that fuse and...

Страница 13: ...for individual circuit tests with reference to the prop ertie board Figures 18 to 21 Trouble Check 1 Completely Are boards plugged in correctly inoperative Is battery connected and fully charged 23 V...

Страница 14: ...rcuit compo nents The control may be inoperative and possible misoperation unintentional operation of the recloser may result 82047KMA Pre Check When troubleshooting a control reported to have failed...

Страница 15: ...or change the diode board first because The diode board circuits operate in conjunction with the tim ing plugs the output circuit reset circuit and reclosing cir cuit A primary diode failure on the di...

Страница 16: ...gure 21 Form 3A electronic control back panel The test points listed above will be covered in detail in the Detailed Circuit Check section of this manual Type ME Electronic Recloser Control 16 88939KM...

Страница 17: ...istors 0 17 Vac 170 millivolts Ground Resistors 0 26 Vac 260 millivolts NOTE The above voltages are proportional to the recloser line current and can be used to calculate the actual load current on th...

Страница 18: ...2040KMA INTERNAL dc LOAD CURRENT SIGNAL To check the dc load current output signal measure the volt age at tie board test points listed in Table 3 at 100 minimum trip current Failure to get these sign...

Страница 19: ...to troubles on the phase trip No 2 or ground trip No 2 circuit boards or possi bly with the phase trip No 1 or ground trip No 1 boards Battery voltage below 21 Vdc will cause control misoperation of...

Страница 20: ...nimum trip level Failure to get a sudden voltage change for a fast TCC plug or a gradual change for a slow TCC plug can be caused by trouble on the phase trip No 2 or ground trip No 2 board trouble on...

Страница 21: ...tionships of terminal pin location on the tie board and rear of front panel see Figures 18 and 19 82040KMA Figure 33 Form 3 test points forTCC operation Table 5 For relationships of terminal pin locat...

Страница 22: ...2 CONTROL RECLOSER OPERATION To provide a better understanding of the control operational cir cuit checks and the relationship between the recloser circuits and the control output typical recloser con...

Страница 23: ...oser trip operations Table 6 For rela tionship of terminal test points see Figures 2 18 and 19 82040KMA TABLE 6 Test Points forTrip Operating Circuit Figures 36 37 and 38 Trip signals have a time dura...

Страница 24: ...Appendix 11 TABLE7 Test Points for Closing Tripping and Reclosing Circuit Figures 39 40 41 Closing signal is about 0 5 seconds depending on recloser type Value may vary depending on recloser type Rec...

Страница 25: ...and reclosing operation Table 7 For relationship of terminal test points see Figures 2 18 and 19 82040KMA Figure 41 Form 3 test points for closing tripping and reclosing opeation Table 7 For relation...

Страница 26: ...e circuit board Repair involves replacement of the circuit board Unstable minimum trip volt age levels will upset or prevent automatic reset operation TABLE 8 Test Points forTrip and Reset Circuit Fig...

Страница 27: ...S280 75 2 27 Figure 43 Form 3 test points for trip reset operation Table 8 For relationship of terminal test points see Figures 2 18 and 19...

Страница 28: ...Figure 44 Form 3A test points for trip reset operation Table 8 For relationship of terminal test points see Figures 2 20 and 21 Type ME Electronic Recloser Control 28...

Страница 29: ...d in the event of major control damage check the continuity of common tie board terminals listed in Table 9 Form 3 and Table 10 Form 3A Failure to get continuity for any of the test points indicates t...

Страница 30: ...e ME Electronic Recloser Control 30 88948KMA TABLE 10 Form 3ATie Board Continuity Checks Figure 46 Continuity from Terminals A To Lamp 5A Counter 1 Continuity from Terminals N 1 To L 2 4B For controls...

Страница 31: ...d MEA 1172 See Figure 48 A typical charging rate will be about 27 mA at normal room temperature NOTE The 17 mA charging rate is a nominal value based on a 27 volt battery and rated input parameters e...

Страница 32: ...Figure 49 Block diagram of test points for battery charging circuitry See Figures 50 and 51 andTale 12 for specific testing points and values Type ME Electronic Recloser Control 32...

Страница 33: ...Potential battery charging 120 240 120 240 Connections and wire from terminal strip board Fused switch B Outgoing Fused switch 120 240 Fuses B1 B2 Outgoing Potential battery charging 35 38 52 55 Shor...

Страница 34: ...Figure 51 Form 3A test points for battery charging circuitry Table 12 Type ME Electronic Recloser Control 34...

Страница 35: ...COMMON AC GND terminal is connected to the control cabinet If the incoming 120 Vac supply is inadvertently connect ed to the common terminal the control cabinet will be at 120 Vac potential Contact w...

Страница 36: ...4 Charge the battery for 48 hours with the KA1142ME battery charger 5 Place a 10 ohm load a KA638ME voltmeter or MET Tester has this built in across the battery for approximately 2 3 sec onds The vol...

Страница 37: ...DIAL SETTING GND LOCKOUT PHASE TOGGLE SWITCH POSITION TCC PLUGS GND 1st 2nd GND SWITCH BLOCK PHASE 1st 2nd GND SWITCH NORMAL COUNTER READING AS FOUND NORMAL RECLOSE BATTERY VOLTAGE AS FOUND NON RECLOS...

Страница 38: ...Monitor S280 75 61 2 3 3A KA1142ME3 Portable Dual Rate Battery Charger Catalog No Description KA216ME1S Ground Trip Timing Plug Curve 1 KA216ME2S Ground Trip Timing Plug Curve 2 KA216ME3S Ground Trip...

Страница 39: ...ssory When Energized for 12O Vac for Form 3 Above 5500 to 26000 KA333ME9 Blocking of Reclosing Accessory When Deenergized for 240 Vac for Form 3 Above 5500 to 26000 KA333ME10 Blocking of Reclosing Acc...

Страница 40: ...4V for Lockout Indicator Type ME Electronic Recloser Control 40 TABLE 17 Type ME Control Replacement Parts Acessories Form 2 Above S N 1900 Form 3 Above S N 4000 Form 3A Above S N 26000 continued Cata...

Страница 41: ...S280 75 2 41 APPENDIX V Schematic diagrams Form 2 Connections pages 42 43 Form 3 Connections below S N 5500 pages 44 45 Form 3 Connections S N 5500 25999 pages 46 47 Form 3A Connections pages 48 49...

Страница 42: ...connection diagram below S N 1900 Since late Form 2 and early Form 3 controls share common circuits and design this connection diagram is given for reference Form 2 Connections 42 Type ME Electronic...

Страница 43: ...Figure 54 continued Form 2 Connections continued 43 S280 75 2...

Страница 44: ...Figure 55 Form 3 connection diagram below S N 5500 Form 3 Connections 44 Type ME Electronic Recloser Control...

Страница 45: ...Figure 55 continued Form 3 Connections continued 45 S280 75 2...

Страница 46: ...Figure 56 Form 3 connection diagram S N 5500 to 25999 46 Type ME Electronic Recloser Control Form 3 Connections...

Страница 47: ...Figure 56 continued 47 S280 75 2 Form 3 Connections continued...

Страница 48: ...Figure 57 Form 3A connection diagram 48 Type ME Electronic Recloser Control Form 3A Connections...

Страница 49: ...Figure 57 continued Form 3A Connections continued S280 75 2 49...

Страница 50: ...1 01 P O Box 1640 Waukesha WI 53187 www cooperpower com 2002 Cooper Power Systems Inc Kyle is a registered trademark of Cooper Industries Inc Printed on Recycled Paper Type ME Electronic Recloser Cont...

Отзывы: