background image

Part number here

all products manufactured by Cooper Controls and identified with the Greengate brand are warranted to be free from defects in material and workmanship and 

shall conform to and perform in accordance with seller’s written specifications for a period of :
•  Five (5) years from date of shipment for all occupancy sensors. 

•  three (3) years from date of factory invoice for our hardware and software on lighting Control Panels.

•  We warranty all our standard relays for a period of 10 years from date of factory invoice.  We guarantee the performance of our system to specifications or your 

money back.

this warranty will be limited to the repair or replacement, at seller’s discretion, of any such goods found to be defective, upon their authorized return to seller. this 

limited warranty does not apply if the goods have been damaged by accident, abuse, misuse, modification or misapplication, by damage during shipment or by 

improper service. there are no warranties, which extend beyond the hereinabove-limited warranty, InClUDInG, BUt not lIMIteD to, the IMPlIeD WaRRantY 

oF MeRChantaBIlItY anD the IMPlIeD WaRRantY oF FItness. 
no employee, agent, dealer, or other person is authorized to give any warranties on behalf of the seller or to assume for the seller any other liability in connection 

with any of its goods except in writing and signed by the seller. 
the seller makes no representation that the goods comply with any present or future federal, state or local regulation or ordinance. Compliance is the Buyer’s re-

sponsibility. the use of the seller’s goods should be in accordance with the provision of the national electrical Code, Ul and/or other industry or military standards 

that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous.

P/N 9850-000230-00

Cooper Controls

203 Cooper Circle, Peachtree, Ga 30269

800-553-3879

www.coopercontrol.com 

Содержание Greengate CK4-120NO

Страница 1: ...s being controlled Allow full clearance for the door of the enclosure to open fully 2 Mount the ControlKeeper 4 cabinet using the holes pro vided in the back of the enclosure It is recommended that the panel be mounted vertically 3 All Line Voltage conductors must enter the cabinet on the right side of the enclosure 4 All Low Voltage conductors must enter the cabinet on the left side of the enclos...

Страница 2: ... ControlKeeper 4 panel 5 If using Belden 9841 or 89841 leave all shields disconnected making certain that shield is not exposed 6 Panels and devices on the RS 485 lighting network should be daisy chained Do not create a Star or T Tapped configuration 7 Total network length should not exceed 4000 feet Network Wiring Details 1 Before wiring select the two panels that are going to be the end panels o...

Страница 3: ...voltage wiring is Class 2 wiring 2 All low voltage wiring must enter the cabinet into the Low Voltage section of the enclosure Low Voltage wiring can be brought into the enclosure from the left side of the enclosure Failure to separate high voltage from low voltage wiring may cause interference with logic board function 3 All low voltage wiring must be run in separate conduit from line voltage wir...

Страница 4: ...a daisy chain con figuration No T Taps Stars should be used The GDS I device should reside somewhere within the daisy chain switch net work Total daisy chain network length should not exceed 1000 feet The following instructions describe the GDS I device connec tion to the ControlKeeper 4 Please refer to the Digital Switch Installation Instructions for information on wiring the Digital Switch netwo...

Страница 5: ... for relays to run programmed scheduling the hardware override switch must be in the AUTO or center position See Figure 9 for location of the hardware override switch LED Operation The ControlKeeper 4 has LEDs for status monitoring They consist of System Status LEDs and Relay Status LEDs Figure 10 ControlKeeper 4 Status LEDs System Status LEDs There are six 6 system status LEDs that are located in...

Страница 6: ...ft Reset Command press in and then immediately release the reset button in the lower right corner of the logic panel When the reset button is pressed and released the status LED may hesitate briefly then resume normal operation Clear Settings Command A clear settings command is used to remove all programming from a ControlKeeper 4 unit It should be done before downloading programming to the unit f...

Страница 7: ...et Switch 8 Network Terminator Jumper 9 Network Wiring Terminal Block 10 Digital Switch Port 11 Panel Communications Port 12 Peripheral Power Terminal 24VDC DC Ground 13 Switch Input Wiring Channels 14 Panel Network Address DIP Switches Item Reference The ControlKeeper 4 consists of a logic board with a clear separation of line voltage and low voltage components There are several features of note ...

Страница 8: ...modification or misapplication by damage during shipment or by improper service There are no warranties which extend beyond the hereinabove limited warranty INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS No employee agent dealer or other person is authorized to give any warranties on behalf of the Seller or to assume for the Seller any othe...