background image

In Operation

Please do not operate the controller with wet hands, which may lead to 
electric shock.

Please turn off the main power immediately when the safety device starts 
repeatedly or the operation key acts abnormally.
Due to the possibility of electric leakage or overcurrent, accidents such as 
electric shock, a fire and explosion may occur. Please contact the distributor 
or our designated service center.

In case of abnormality (smell of burning, etc.), please stop operation 
immediately and cut off the main power supply. Operation under abnormal 
conditions may lead to failure, electric shock, a fire and other accidents. 
Please contact the distributor or our designated service center.

Strictly prohibit the ingress of water during maintenance. Otherwise it may 
lead to electric shock.

Do not alter the electrical wiring without permission, which may lead to major 
accident.

Do not cut off the power supply within 3 minutes after pressing the key of the 
controller, which may lead to misoperation.

Other Warnings and Precautions

Servicing · Relocation

Please contact the distributor or our designated service center for 
servicing of the air conditioner units.
Improper servicing or installation may lead to electric shock, a fire and 
other accidents.

Please contact the distributor or our designated service center for servicing 
or relocation of the controller.
Improper servicing or installation may lead to electric shock, a fire and 
other accidents.

Warning

Warning

Warning

Safety Instructions

Содержание SPWT-A01

Страница 1: ...her Displays Human Sense 1 1 3 4 4 5 6 6 7 7 13 14 15 16 17 18 19 20 21 22 26 27 Wired Remote Controller Model SPWT A01 Operation Manual Content Thank you for choosing C H commercial air conditioner Please read this manual carefully before using the wired remote controller for a proper operation and keep it properly Should you have any questions please contact with the dealer or our service center...

Страница 2: ... lead to electric shock a fire and other accidents Warning When using medical devices and other devices that produce electromagnetic waves please do not install the wired remote controller directly facing to the transmitting surface of the electromagnetic wave for preventing misoperation of the wired remote controller In order to prevent the electromagnetic wave propagating in the air from affecti...

Страница 3: ...stributor or our designated service center Strictly prohibit the ingress of water during maintenance Otherwise it may lead to electric shock Do not alter the electrical wiring without permission which may lead to major accident Do not cut off the power supply within 3 minutes after pressing the key of the controller which may lead to misoperation Other Warnings and Precautions Servicing Relocation...

Страница 4: ... Ultra far Set temp humidity room temperature Timed power on off Check Service code Quiet Health ECO Sleep Self cleaning Boost Electric heater Nature wind Test run Filter Centralized controller Defrosting 3 2 1 34 33 32 35 36 37 38 39 8 7 6 5 4 22 21 20 23 24 25 26 27 28 29 30 31 9 Dry Heat Auto 10 Fan 11 12 13 14 15 16 17 18 19 On site setting system address Wind free Alarm Lock 11 Display 4 3 8 ...

Страница 5: ...hen connected with total heat exchanger only air supply mode will display Please contact the dealer for details When connected with double source indoor units FAN and HEAT display Please contact the dealer for details Wired remote controller will display dry or auto dry according to the actual condition that whether the connected ducted type indoor units have equipped with humidity sensor or not F...

Страница 6: ...nning 1 In usual mode each press of will increase the temperature by 1 And rapid switching can be realized by holding this button Press The operation goes out and the unit stops Once heating operation is stopped the indoor unit will supply air for around 2 minutes Operation ...

Страница 7: ...ft lower corner shows target humidity value in Dry mode and only temperature value can be adjusted Please contact the dealer for details Room temperature can be displayed after special setting on controller Please contact the dealer for details In usual mode each press of will decrease the temperature by 1 Rapid switching can be realized by holding this button Each press of will decrease the humid...

Страница 8: ...n this function is available in the indoor unit Louver will not display when connected with an indoor unit without louver Louver setting when connected with common 4 way cassette type indoor units Press to start up the unit Press to set louver direction Each press of the button will adjust the direction as the following sequence Press to set air volume Each press of the button the adjust the air v...

Страница 9: ...ual location Sometimes the louver may not stop immediately after pressing the key Louver setting when connected with 3D panel 2 When and is selected and flashing Press and vertical louver swings or changes the angle at stop Each press of the button the vertical louver will display in a flashing manner as the following sequence Press and vertical louver will display in a reverse manner of the above...

Страница 10: ...the following sequence 4 When is selected it flashes for 10s then keep ON Horizontal and vertical louvers are in swing mode at present 5 When is selected it flashes for 10s then keep ON Louvers do not display at present When flashes for 10s the blades move and horizontal louver starts to swing When other icons flash and stop after 10s horizontal louver stops at set location Louver ...

Страница 11: ... Each press of the button the vertical louver will display in a flashing manner as the following sequence Press and vertical louver will display in a reverse manner of the above sequence When flashes for 10s the blades move and vertical louver starts to swing After other icons flash for 10s and stop vertical louver stops at set location Louver setting when connected with 1 way cassette type or kit...

Страница 12: ...ner as the following sequence Press and horizontal louver will display in a reverse manner of the above sequence When flashes for 10s the blades move and horizontal louver starts to swing After other icons flash for 10s and stop horizontal louver stops at set location When flashes for 10s the icon keeps ON Horizontal and vertical louvers are both in swing mode at present Louver ...

Страница 13: ...h press of the button the louvers will display in a flashing manner as the following sequence Louver setting when connected with K3 4 way and K3 2 way cassette type indoor units Louver K3 4 way K3 2 way Press When is selected and flashing separate control of the louver The control mode is switched as the following sequence at each press of the button ...

Страница 14: ...t Press to set additional functions and the selected additional function flashes When icon of additional function is flashing press to switch Each press of the button the icons of additional functions will display as the following sequence When icon of additional function is flashing press to select the Attention additional function press to cancel the additional function ...

Страница 15: ... Heath function is in setting state if it hasn t been set before this function will be valid by pressing If it has been set the function will be canceled by pressing When the unit is switched from ON to OFF the Health mode is canceled When operation mode is changed the Health function does not cancel When the unit is OFF the User can set if Health function will be auto on or off when starts up by ...

Страница 16: ...me is restricted 2 When Sleep function is in setting state if it hasn t been set before this function will be valid by pressing button S S S S S S Sleep Press to select Sleep if the icon of Sleep flashes it is in setting state Attention Press to enter additional function setting interface If it has been set this function will be canceled by pressing ...

Страница 17: ...it is in setting state When Quiet is in setting state if it hasn t been set this function will be valid by pressing button If it has been set this function will be canceled by pressing When setting to Quiet by remote controller the air volume remains at current level and non adjustable Indoor unit will set volume Quiet mode is canceled when the air conditioner is switched OFF Quite mode is cancele...

Страница 18: ...ch to ECO if the icon of ECO flashes it is in setting state When ECO is in setting state if it hasn t been set before this function will be valid by pressing If it has been set this function will be canceled by pressing When setting ECO function by wired remote controller set air volume and temperature are non adjustable Indoor unit will set air volume and temperature automatically ECO mode is can...

Страница 19: ...n Electric Heater is in setting state if it hasn t been set before this function will be valid by pressing If it has seen set this function will be canceled by pressing Electric Heater is available only in Heat mode Electric Heater is canceled when the air conditioner is switched OFF Electric Heater is canceled when the operation mode is changed This function is not available when connected with a...

Страница 20: ...be valid by pressing If it has been set this function will be canceled by pressing Nature Wind is available only in Cool mode Nature Wind is canceled when the air conditioner is switched OFF Nature Wind is canceled when the operation mode is changed When setting Nature Wind both set air volume and direction are non adjustable indoor unit will take control over the air volume and direction When con...

Страница 21: ...by pressing And FAN and LOUV icons do not display If it has been set this function will be canceled by pressing And FAN and LOUV icons display Wind Free Wind Free is available only in FAN COOL HEAT and DRY modes Wind Free is canceled when the air conditioner is switched OFF Wind Free is canceled when setting of FAN or LOUV is changed Press to switch to Wind Free and if it flashes it is in setting ...

Страница 22: ...n setting interface Press to switch to Human sense if the icon of Human sense flashes it is in setting state When Human sense is in setting state if it hasn t been set this function will be valid by pressing If it has been set this function will be canceled by pressing Human sense is canceled when the air conditioner is switched OFF 1 2 ...

Страница 23: ...only the icon of Self cleaning display In Self cleaning mode no button works except for 3 Self cleaning Press in OFF state if the icon of Self cleaning flashes it is in setting state Attention When Self cleaning is in setting state if it hasn t been set this function will be sel cted by pressing If it has been set this function will be canceled by pressing ...

Страница 24: ...g it may give off the sound of cracking which is a normal phenomen and will disappear after cleaning When Self cleaning exits there may be steams occasionally which is a normal Optimum conditions for frost removal indoor temp 59 15 humidity 60 outdoor temp at 32 104 0 40 When humidity is less than 20 frost removal will be affected It is suggested to perform self cleaning in the transiting season w...

Страница 25: ...ge is 0 10h the adjustment accuracy is 0 5h When timing range is 10 72h the adjustment accuracy is 1h When Timer power on is in setting state Each press of will increase the timing by 0 5h Each press of will decrease the timing by 0 5h When Timer power on is in setting state and the time is adjusted according to demand this function is successfully set by press Timer power on Timer power on Timer ...

Страница 26: ...imer setting interface Then displays and timer flashes When Timer power off is in setting state Each press of will increase the timing by 0 5h Each press of will decrease the timing by 0 5h When Timer power off is in setting state and the time is adjusted according to demand this function is successfully set by press When Timer power off is in setting state this function will be canceled by press ...

Страница 27: ...When locked hold simultaneously for over 5s to unlock And buttons work again Unlock When locked hold simultaneously for over 5s to unlock And buttons work again The locked button is determined by values of F8 Mode F9 Temperature FA Fan FB Louver FF Timer in option settings the locking is valid only when all the values of the above items are set to 1 ...

Страница 28: ... Controller When voiding remote controller through central controller the remote controller is not able to set operation temperature mode air volume louver Filter The icon li up when filter requires cleaning Press will clear the icon ...

Страница 29: ...ation after recovery of power source supply if the shutdown is due to power failure Please re perform running operation Instantaneous power failure of around 2s will not interrupt operation of air conditioner after recovery of power source supply All icons disappear Operation may also stop This is due to the protection actions from micro processor against disturbance Please re perform running oper...

Страница 30: ......

Страница 31: ......

Страница 32: ...08 2022 V00 The Company is committed to continuous product improvement We reserve the right therefore to alter the product information at any time and without prior announcement ...

Отзывы: