For CH-09DKT230VI, CH-12DKT230VI
,
CH-18DKT230VI
1R
1DPH
&1
0HDQLQJ
1
Power Supply
CN3
Earth: connect to Ground
CN1
N_in: connect to N-line (100-130V AC input)
CN2
L_in: connect to L-line (100-130V AC input)
2
S
CN16
S: connect to indoor unit communication
3
HEAT1
CN17
connect to compressor heater, 100-130V AC when is ON
4
4-WAY
CN60
connect to 4 way valve, 100-130V AC when is ON.
5
AC-FAN
CN25
connect to AC fan
6
TP T4 T3
CN21
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust
temp. sensor TP
7
HEAT2
CN15
connect to chassis heater, 100-130V AC when is ON
8
PMV
CN31
connect to Electric Expansion Valve
9
DC-FAN
CN7
connect to DC fan
10
FAN_IPM
IPM 501 IPM for DC fan
11
TESTPORT
CN6
used for testing
12
EE_PORT
CN505
EEPROM programer port
13
MCUPORT
CN507
connect to PC communication
14
W
CN28
connect to compressor
V
CN29
0V AC (standby)
U
CN30
10-230V AC (running)
15
COMP_IPM
IPM 301 IPM for compressor
16
BR1
BR1
Bridge