9
4. Refrigerant Cycle Diagram
LIQUID SIDE
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
Compressor
2-WAY VALVE
3-WAY VALVE
4-WAY VALVE
COOLING
HEATING
T2 Evaporator
temp. sensor
T1 Room temp.
sensor
T3 Condenser
temp. sensor
Accumulator
TP Discharge temp. sensor
T4 Ambient
temp. sensor
INDOOR
OUTDOOR
Electronic
expansion valve
CAPILLARY
tube
Содержание CH-09DKT230VI
Страница 29: ...27 IPM board TO MAIN W connecttothecompressor V OVAC standby 10 200VAC running...
Страница 41: ...39 P W N U...
Страница 42: ...40 N V N W...