The Coonara Clear View Gas log Heater has been designed for a simple and efficient operation to
provide you with a higher heat output than most other heaters in the market. The heater will provide
you with a fully controlled modulated supply of heat, from a pleasant and steady warmth to the
strongest heat output, to reach almost any corner of your area.
PRE OPERATIONS CHECKS
Prior to operating the heater, ensure that the flue terminal is not obstructed. Furthermore, make sure
there are no combustible objects leaning against, resting on, or within the immediate vicinity of the unit.
Check that the heater main power and gas supply are connected and switched on.
OPERATING THE HEATER
The heaters are operated by the room thermostat
1 -
To ignite your heater press
Powe
r
Button
on the thermostat and the heater will automatically start
the ignition sequence. Please refer to the Thermostat Operating Manual supplied for further
instructions. After approximately 30 seconds of self-checking the heater will ignite.
2 -
The heater will
always start in the low heat
setting and (unless already warm) the heater will
warm
up for at least 2 minutes
before automatically going to the higher flame setting.
3 –
The Room fans will not start till at least
2
minutes of
warming up
period.
4
- During first time firing of this appliance, an odour may be noticed for a short period of time while
the paint cures. It is advisable to leave the windows open during the first few hours of the very first
operation only.
TURNING THE APPLIANCE OFF
Press power button on thermostat once. The room fan will continue to operate for a period of about 8
minutes while the heater cools down.
Please note:
1 - This appliance cannot be operated without the fan running.
2 - Due to the performance and efficiency of the heater, steam may be noticed coming from the flue
terminal on cool days.
3 - As this appliance has a luminous effect some slight carbon deposition may occur.
OPERATING THE CLEAR VIEW AND BAROSSA HEATER
During first time firing of this appliance, an odour may be noticed for a short period of time while the
paint cures. It is advisable to leave the windows open during the first few hours of the very first
operation only.
When the heater is turned on there is an initial delay time (purge time) of 30 seconds. Once this time
has elapsed, your heater will light via the electronic ignition system. Regardless of the heat setting, the
heater will start on high for approximately 10 seconds before switching back to the last heat setting
used. There will be a further 2 minutes delay before the room air fan turns on.
When the room temperature is approaching the set temperature, the flame will begin to diminish. Once
the room temperature reaches the set temperature the heater will go to minimum flame. If the room
temperature begins to fall the flame will then increase.
Содержание Barossa
Страница 9: ...Revised 15 02 16 31 03 2016 9 ALL MODELS ARE TO BE PLACED ON A FLAT LEVEL SURFACE TO PREVENT RATTLES...
Страница 13: ...Revised 15 02 16 31 03 2016 13 CLEAR VIEW DOUBLE SIDED EXTERNAL DIMENSIONS FOR WALL THICKNESS 100MM TO 248MM...
Страница 15: ...Revised 15 02 16 31 03 2016 15 CLEAR VIEW DOUBLE SIDED EXTERNAL DIMENSIONS FOR WALL MAXIMUM THICKNESS 248MM...
Страница 17: ...Revised 15 02 16 31 03 2016 17 BAROSSA SINGLE SIDED EXTERNAL DIMENSIONS...
Страница 18: ...Revised 15 02 16 31 03 2016 18 BAROSSA SINGLE SIDED...
Страница 20: ...Revised 15 02 16 31 03 2016 20 WIRING DIAGRAM...
Страница 23: ...Revised 15 02 16 31 03 2016 23 STEP 3 STEP 4 STEP 5...
Страница 24: ...Revised 15 02 16 31 03 2016 24 STEP 6 LOG SET FRONT VIEW...