Revised: 15/02/16 

 

31/03/2016 

2

WARNING 

  
 

THE FOLLOWING INSTRUCTIONS MUST BE CARRIED OUT OR 

WARRANTY BECOMES VOID.  

 
 

Heater must be installed by a Coonara authorised technician. List is available 
on  www.shamicheating.com.  You  must  obtain  a  license  number  from  the 
installer. 

Inbuilt  and  Freestanding  Heaters  must  be  placed  on  a  flat  level  surface.  
Inbuilt  models  must  be  placed  on  6mm  AC  sheeting,  to  prevent  unit  from 
rattling.

 

Heater must be checked for scratches or dents prior to installation. 

All glass must be fitted with a screw driver not a drill.  If glass is broken upon 
installation due to the screws being tightened too  much, it will not be classed 
under warranty. 

Further  safety  precautions  and  installation  instructions  are  contained

 

throughout this manual.  Please read the manual before installation.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Barossa

Страница 1: ...l Number of Heater ____________ Model ___________________ Serial Number of Heater ____________ Model ________________ Clear View Barossa Inbuilt Gas Log Heaters ARE AUSTRALIAN OWNED AND MANUFACTURED B...

Страница 2: ...must be placed on a flat level surface Inbuilt models must be placed on 6mm AC sheeting to prevent unit from rattling Heater must be checked for scratches or dents prior to installation All glass must...

Страница 3: ...6 7 SAFETY FEATURES 7 INSTALLATION INSTRUCTIONS 8 15 DIMENSIONS INBUILT MODELS 16 18 PRESSURE ADJUSTMENTS 19 WIRING DIAGRAM PRESSURE SWITCH 20 PRESSURE SWITCH BURNER REMOVAL 21 LOG SET 22 24 WARRANTY...

Страница 4: ...nufacturer MODEL TYPE GAS INPUT HIGH LOW HEAT OUTPUT HIGH LOW Efficiency Injector Size Manifold Pressure High Low A G A Aproval Number to Code AS NZ 4553 2008 Inbuilt 36 MJ h 27 MJ h 8 7 kW 4 3 kW 84...

Страница 5: ...ty supply cord is damaged it must be replaced with an original Coonara part obtainable from your authorized dealer THE SAFETY GUARD AROUND THE GLASS DOOR IS FITTED TO THIS APPLIANCE TO REDUCE THE RISK...

Страница 6: ...is appliance an odour may be noticed for a short period of time while the paint cures It is advisable to leave the windows open during the first few hours of the very first operation only TURNING THE...

Страница 7: ...blockage of airways or incorrect gas installation the gas supply will automatically shut off after 5 minutes aproximate This is due to temperature increase and to prevent the appliance from over heati...

Страница 8: ...pliance and can be optionally installed in a false fireplace or wall cavity made of combustible materials such as wood or chipboard Coonara provide the heater with their own flue kit of flexible pipes...

Страница 9: ...Revised 15 02 16 31 03 2016 9 ALL MODELS ARE TO BE PLACED ON A FLAT LEVEL SURFACE TO PREVENT RATTLES...

Страница 10: ...e pipes 2 Feed both flexible pipes down the flue cavity 3 Fix flue terminal securely to top of the flue cavity and seal to prevent water entry Seal with Hi temperature waterproof silicon sealant prior...

Страница 11: ...set Packed inside with heater 2 Carefully remove the cardboard carton surrounding the heater 3 Remove fascia on Barossa both fascias on the Clear View To remove fascia undo 2 screws either end of air...

Страница 12: ...A 1000mm B 245mm inc plaster C 900mm See below Rear Opening A 1125mm B 245mm C 900mm See below Barossa A 1000mm B 400mm inc plaster C 900mm See below Gas Inlet to be Fem BSP Power Outlet left hand sid...

Страница 13: ...Revised 15 02 16 31 03 2016 13 CLEAR VIEW DOUBLE SIDED EXTERNAL DIMENSIONS FOR WALL THICKNESS 100MM TO 248MM...

Страница 14: ...ccommodate plaster board this can be adjusted to accept 30mm i e allowance for tiles To adjust take off the plate undo 4 screws slide the spigot forward then tighten screws Make sure screws are tight...

Страница 15: ...Revised 15 02 16 31 03 2016 15 CLEAR VIEW DOUBLE SIDED EXTERNAL DIMENSIONS FOR WALL MAXIMUM THICKNESS 248MM...

Страница 16: ...commodate plaster board this can be adjusted to accept 30mm i e allowance for tiles To adjust take off the plate undo 4 screws slide the spigot forward then tighten screws Make sure screws are tight a...

Страница 17: ...Revised 15 02 16 31 03 2016 17 BAROSSA SINGLE SIDED EXTERNAL DIMENSIONS...

Страница 18: ...Revised 15 02 16 31 03 2016 18 BAROSSA SINGLE SIDED...

Страница 19: ...eset and adjusted and should not need to be re adjusted during installation Gas pressures still need to be checked to the pressures shown on Page 4 of this manual But there will be some situations whe...

Страница 20: ...Revised 15 02 16 31 03 2016 20 WIRING DIAGRAM...

Страница 21: ...curs the part needs to be replaced by following these instructions 1 Remove 2 screws one at each end of air intake Then lift and pull the fascia towards you This will unclip the two hanging hooks 2 Un...

Страница 22: ...2 16 31 03 2016 22 COONARA CLEAR VIEW BAROSSSA LOG SET LOCATION DETAILS All logs have self locating points moulded into them This allows for accurate positioning of logs STEP 1 STEP 2 Fixed logs part...

Страница 23: ...Revised 15 02 16 31 03 2016 23 STEP 3 STEP 4 STEP 5...

Страница 24: ...Revised 15 02 16 31 03 2016 24 STEP 6 LOG SET FRONT VIEW...

Страница 25: ...he heater 5 Advise them of the specific problem 6 Provide the details that your retailer requests to complete a Warranty Claim Form This must include the heater model serial number and installation co...

Страница 26: ...the heater not in accordance with both the installation and operation instructions furnished with the unit c This warranty does not apply to any heater which has been modified or damaged in shipping o...

Страница 27: ...patch your warranty card to Shamic Sheetmetal Aust Pty Ltd 9 Your authorised dealer must be notified of any defect in the heater for investigation of the claim Your authorised dealer will be able to e...

Страница 28: ...lve Check wiring Room fan not operating Insufficient time allowed Loose wiring Fan not located correctly Fan blocked Fan has a delayed start and will not start until unit warms up Check wiring Install...

Страница 29: ...l info shamic com au DETACH AND RETURN BY MAIL NAME _______________________________________________________________ ADDRESS____________________________________________________________ CITY STATE POSTC...