41
COOLIUS Y50A
6.6 Report
The machine records the refrigerant usage monthly for the previous twelve months. Beyond this period, it will
overwrite the data for the month in question.
1. Turn
COOLIUS SELECT
to select the following coun-
ters:
•
Refrigerant recovered from
A/C system
•
Refrigerant recovered from
external tank
•
Refrigerant filled to A/C system
The display shows in sequence all the months and the total per year.
2. Press
START
to print the report.
01/2018
HFO recovered
Kg. 10.0
2018
Total
HFO recovered
Kg. 210
6.7 Scale reset
At the purpose to compensate the scale deviation, perform the following instructions:
1. Turn
COOLIUS SELECT
to select
Other selections
, confirm by
ENTER
,
2. Turn
COOLIUS SELECT
to select
Scale reset
3. Press
ENTER
to confirm.
4. Turn
COOLIUS SELECT
to select the scale:
•
“Refrigerant Weight scale”
•
“Waste oil Weight scale”
5. Press
ENTER
to confirm.
Scale reset
Select:
Refrig. Weight scale