14
Type of gas used
Model
5 BURNERS
Rated thermal
(kW)
Total rated
consumption
G20 20 mbar
1AUX – 2SR – 1R – 1TC
11.15
1063 lt/h
G30 28-30 mbar
1AUX – 2SR – 1R – 1TC
11.10
807 g/h
G31 37 mbar
1AUX – 2SR – 1R – 1TC
11.10
793 g/h
Burner
Minimum Pan
Diameter (cm)
Maximum Pan
Diameter (cm)
Auxiliary
≥10
≤18
Semi Rapid
≥14
≤24
Rapid
≥16
≤26
Triple Crown
≥20
≤26
Operation
Burner operation
• Push and turn the knob around to the spark zone of the control until the gas lights.
• Reduce the gas level to suit the cooking required.
• If the gas fails to light first time, please try again.
CAUTION:
• If there is no electric current you can light the burners with a piezo electric spark
gas ignitor.
• The burners can only be lit with safety thermocouples when the knob is on MAXIMUM.
• Do not use cooking vessels on the hob that overlap the edges of the pan supports.
TRAG10584 - 200000010 - Cooke and Lewis 5 Burner Gas on Glass v3b Rv2.indd 14