33
In
more
detail...
GB IE
Electrical Requirements
Any permanent electrical installation must comply with the latest
I.E.E. Regulations and local electricity company regulations. For
your own safety a qualified electrician or contractor who is on the
roll of the National Inspection Council for Electrical Installation
Contracting (NICEIC) should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate inside
the appliance.
WARNING: THIS APPlIANCE MUST BE EARTHED
The appliance is supplied with a 3-core mains cable and must be
connected to the electricity supply via a double pole switch having
a 3mm minimum contact gap on each connector.
For UK only
A Switched Fused Connection Unit to BS 1363 Part 4 is
recommended.
The fuse must be rated at 13 Amps.
The wires in the mains lead are coloured in accordance with the
following code:
Brown = l - live
Blue = N - Neutral
Green and Yellow = - Earth
The connection point must be placed in a position adjacent to the
appliance so as to be readily accessible for an engineer in the
event of a breakdown.
Disconnect the appliance from the mains supply before
carrying out any kind of maintenance or cleaning.
Technical and legal
information
Содержание CLEF4BK-C
Страница 1: ...CLEF4BK C V5c Barcode 5052931071791 GB IE CLEF4BK C ...
Страница 2: ... 07 x 4 Ø3 9 x 32mm 06 x 4 01 x 1 05 x 1 02 x 2 03 x 1 04 x 1 ...
Страница 3: ...3 GB IE Built In Multifunction Fan Oven 04 Installation 37 CLEF4BK C ...
Страница 5: ...5 Getting Started Getting started GB IE Before you start 06 Safety 09 ...
Страница 37: ...37 Appendix Appendix GB IE Installation ...
Страница 40: ...40 Appendix Appendix GB IE Installation 550mm 60 mm 600 mm 85 90mm Minimum ventilation gap 80cm 2 85 90mm ...
Страница 43: ...43 Notes ...