Convey HC-1EX Server Quick Start Guide v1.3
4
System fan assembly, including four dual-rotor fans, installed in Convey CP
section on a removable access panel.
Passive hot-swap disk backplane
Optional RMM2 module and NIC
Rack Mount Usage
2.4
The system ships with slide rails that accommodate cabinet mounting rail spacing from
24 to 30 inches. Cabinet mounting rails must include square hole mounts on ANSI/EIA-
310 spacing.
When installing the rails into the cabinet refer to Figure 2:
Compress the cabinet rail mount width-compensation slide to the minimum (24
inch dimension).
Install the rear mounts first and listen for the audible click to confirm they are
properly secured.
Install the front mount by extending the width-compensation slide until the front
mount clicks secure.
Test the slides by shaking them to confirm secure slide installation prior to
installing the system.
If a screw is desired to hold the slide, it must be a 10-32 with large washer.