CONVECTAIR DIVA 7647 Скачать руководство пользователя страница 9

   

  RECOMMANDATIONS DE MISE EN PLACE

   

  RECOMMANDATIONS DE MISE EN PLACE

   

  1

   

  1

OVERHEAT  CONTROL

MAINTENANCE

6

7

- This heater is equipped with separate overheat controls for the radiant panel and for the 
fan-forced heat. In case of a malfunction of the unit (blocked air output or intake, for 
example) the heater will stop heating automatically. After correcting the malfunction the 
heater can be reset. To restart the heater :

- For the radiant heater, check that the top outlet grill (top back of the heater) is free of 
obstruction, then push the reset button on the upper back panel of the heater.

- For the fan-forced heat : Turn the heater Off.   Check that the lower back inlet and the 
lower front outlet are free of obstruction.  Wait 5 minutes and turn the heater back on.
If  the  light  is  still  off,  and  no  heat  is  generated,  call  your  electrician  or  the  nearest 

CONVECTAIR

 repair center.

-    To  keep  your  CONVECTAIR  unit  clean,  regular  maintenance  is  suggested.  To 
remove dust, use a soft cloth. To remove a stain, use a damp cloth. For a better 
performance and maximum efficiency, it is suggested that dust and lint be regularly 
removed from the protective grill situated at the back of your DIVA .

NEVER  USE  ABRASIVE  OR  ACETONE-BASED  PRODUCTS  TO  CLEAN  YOUR 
HEATER AS THIS MAY DETERIORATE THE EPOXY FINISH.

ANY REPAIR ON YOUR CONVECTAIR HEATER SHOULD ONLY BE DONE BY A 
QUALIFIED   TECHNICIAN,   AND   ONLY   AFTER   THE   HEATER  HAS  BEEN 
DISCONNECTED.

Your 

CONVECTAIR

 heater will become hot when in use. Caution is advised when young children are 

present.

Do not insert small objects in the heater : this could cause an electrical short circuit, fire or damage to the 
inner components.

Any use or modifications not approved by CONVECTAIR may cause electrical short circuits, fire or injuries 
to the users.

In  certain  cases,  it  is  possible  for  yellowing  of  the  surface  to  occur  over  time.  This  is  not  due  to  a 
manufacturing defect. This is caused by surrounding air, which may contain smoke or dust, being heated 
and circulated through the heater.

Prevention : it is suggested that surfaces be frequently cleaned especially with units installed in 
locations  where  cigarette  smoke  is  present  or  in  the  kitchen.  Never  use  this  heater  during 
construction work or other activities that generate a lot of dust.

Note : The first time your CONVECTAIR heater is used, a light smoke could be released. This is normal       
and should disappear after about 2 to 3 minutes.

Operation and maintenance tips

9.

Содержание DIVA 7647

Страница 1: ...Installation Operating Instructions ATTENTION Documents to be kept by end user DIVA 7647 421AA2219 ...

Страница 2: ...e 4 Page 4 Page 5 Page 6 Page 7 Page 9 Page 9 Page 10 Page 10 Page 10 INTRODUCTION Dear owner Congratulations on the purchase of this premium electric heater CONVECTAIR develops and produces the highest quality heating product in the electrical industry To obtain the best results and the ultimate in performance and comfort please take a moment to read the installation operation and maintenance ins...

Страница 3: ...n box 30 cm 12 in from the floor centered on the heater Installing and connecting the heater See pages 5 and 6 To turn the heater ON or OFF Press the On Off Turbo switch briefly To set the temperature Set the temperature dial at 6 see page 7 Wait for the temperature to stabilize Adjust up or down for the required comfort level Fast heat With the heater ON press the timer switch Once hr Twice 1 hr ...

Страница 4: ... temperature set backs in periods of prolonged absence providing the same comfort and more savings Your heater must be installed in accordance with national and local codes and CONVECTAIRrecommendsaninstallationbyaqualifiedelectrician Your heater must be installed so that the control panel is out of reach from anyone in the bath tuborintheshower Donotinstalloverabath tuborspa Do not install the he...

Страница 5: ...AUTION Use screws and anchors adapted to the wall type and weight of the heater 12 5 kg 27 5 lbs not including towels Hook the heater on the top bracket Mark the location of the bottom bracket hole Fasten the lower bracket to the wall with a pro per screw and anchor The heater should be installed no lower than 25 cm 10 in from the floor Leave a minimum clearance of 10 cm 4 in on each side of the h...

Страница 6: ...cations to avoid any danger CAUTION Thisheatermustbeconnectedtoa240Voltor208Volt 60cycles circuit Disconnect the power supply before making wiring connections to prevent electrical shock and equipment damage If you are using a Programmer system make sure to cut the power off ALL electrical heating circuits in the home for moreinformation seetheCONVECTAIRmodel7392installationnotice A standard recta...

Страница 7: ...ingelementhasbeenturnedon Close the doors and windows to the room where the heater is located Let the temperaturestabilizeforanhour Ifthetemperatureisnotquiteright adjustthethermostatdialupordownbyhalfamark Let the temperature stabilize for another hour before checking again and repeat if necessary withaquarteradjustmentthistime Once the thermostat is set at the desired comfort setting do not touc...

Страница 8: ...itchtoselect1hr 2hrortostoptheunheatedventilation Whenthecycleisfinished theunheatedventilationindicatorlightremainson Tostarttheunheatedventilationagain pressthetimerswitchfortheselectedduration To turn the unheated ventilation off press the On Off Turbo switch briefly shutting the heateroff TURBOMode Duringcolderperiods thisspecialsettingallowsyourDivatoactasa1500wattheaterwith thermostatcontrol...

Страница 9: ...romtheprotectivegrillsituatedatthebackofyourDIVA NEVER USE ABRASIVE OR ACETONE BASED PRODUCTS TO CLEAN YOUR HEATERASTHISMAYDETERIORATETHEEPOXYFINISH ANY REPAIR ON YOUR CONVECTAIR HEATER SHOULD ONLY BE DONE BY A QUALIFIED TECHNICIAN AND ONLY AFTER THE HEATER HAS BEEN DISCONNECTED Your CONVECTAIR heater will become hot when in use Caution is advised when young children are present Do not insert smal...

Страница 10: ...on the lower right hand side of the heater same side as the thermostat It includes The complete model number and its production reference number A that must be included in any warranty claim Capacity B Standard certification C 2yearsagainstalldefects 5years onheatingelement All CONVECTAIR heaters are subject to a double warranty 2 years on all parts and manufacturing defects and 5years on the heat...

Отзывы: