CONVECTAIR DIVA 7647 Скачать руководство пользователя страница 4

       Model #          Volts,                Capacity           Height       Width      Width       Depth       Depth      Weight 

  7647-C15

  240V, 60 Hz

  102 cm
    (40”)

  44,5 cm

1/2

   (17  “)

   50 cm

3/4

  (19  “)

   12 cm

3/4

   (4  “)

  21,5 cm

1/2

   (8  “)

   12,5 Kg
  (27,5 lbs)

      1500 W
  

(700W radiant,

800W fan forced)

                                 cycles                                                                                with bars                      with bars                                       

   

  RECOMMANDATIONS DE MISE EN PLACE

   

  1

   

  1

- Your new Diva combines both radiant and fan-forced heat. It is designed to heat the room 
as well as to dry towels, a perfect combination for the bathroom.

- The Diva is composed of a silent radiant vertical panel of 700 watts, controlled by an 
electronic thermostat, to heat the room and dry towels. The fast-acting boost provides 
1500  watts  of  combined  radiant  and  fan-forced  heat,  with  a  timer  control.  A  bottom 
opening directs the warm air on the towels as well as towards the center of the room.

- Your Diva can be used with the optional CONVECTAIR Programmer Module (pilot wire) 
allowing scheduled temperature set-backs in periods of prolonged absence providing the 
same  comfort  and  more  savings.

-  Your  heater  must  be  installed  in  accordance  with  national  and  local  codes  and 
CONVECTAIR recommends an installation by a qualified electrician.

- Your heater must be installed so that the control panel is out of reach from anyone in the 
bath-tub or in the shower.  Do not install over a bath-tub or spa.

- Do not install the heater behind a door, furniture or other obstacles, or in front of an air-
exhaust vent.   Keep combustible materials such as curtains, away from the heater.

- Your heater is equipped with a heating element that may reach high temperatures.  Do 
not  install  or  operate  in  the  presence  of  gasoline,  paint  solvents  or  other  flammable 
products.

- In order to avoid overheating, use the towel bars when drying clothes or linen.

- Maintain the minimum required clearances (height from floor, distances from side walls 
or furniture, drapes, etc).

SPECIFICATIONS

RECOMMENDED SET-UP

1

2

4.

Nota :

 when connected at 208V, the capacity is 1125W (525W radiant, 600W fan-forced)

Содержание DIVA 7647

Страница 1: ...Installation Operating Instructions ATTENTION Documents to be kept by end user DIVA 7647 421AA2219 ...

Страница 2: ...e 4 Page 4 Page 5 Page 6 Page 7 Page 9 Page 9 Page 10 Page 10 Page 10 INTRODUCTION Dear owner Congratulations on the purchase of this premium electric heater CONVECTAIR develops and produces the highest quality heating product in the electrical industry To obtain the best results and the ultimate in performance and comfort please take a moment to read the installation operation and maintenance ins...

Страница 3: ...n box 30 cm 12 in from the floor centered on the heater Installing and connecting the heater See pages 5 and 6 To turn the heater ON or OFF Press the On Off Turbo switch briefly To set the temperature Set the temperature dial at 6 see page 7 Wait for the temperature to stabilize Adjust up or down for the required comfort level Fast heat With the heater ON press the timer switch Once hr Twice 1 hr ...

Страница 4: ... temperature set backs in periods of prolonged absence providing the same comfort and more savings Your heater must be installed in accordance with national and local codes and CONVECTAIRrecommendsaninstallationbyaqualifiedelectrician Your heater must be installed so that the control panel is out of reach from anyone in the bath tuborintheshower Donotinstalloverabath tuborspa Do not install the he...

Страница 5: ...AUTION Use screws and anchors adapted to the wall type and weight of the heater 12 5 kg 27 5 lbs not including towels Hook the heater on the top bracket Mark the location of the bottom bracket hole Fasten the lower bracket to the wall with a pro per screw and anchor The heater should be installed no lower than 25 cm 10 in from the floor Leave a minimum clearance of 10 cm 4 in on each side of the h...

Страница 6: ...cations to avoid any danger CAUTION Thisheatermustbeconnectedtoa240Voltor208Volt 60cycles circuit Disconnect the power supply before making wiring connections to prevent electrical shock and equipment damage If you are using a Programmer system make sure to cut the power off ALL electrical heating circuits in the home for moreinformation seetheCONVECTAIRmodel7392installationnotice A standard recta...

Страница 7: ...ingelementhasbeenturnedon Close the doors and windows to the room where the heater is located Let the temperaturestabilizeforanhour Ifthetemperatureisnotquiteright adjustthethermostatdialupordownbyhalfamark Let the temperature stabilize for another hour before checking again and repeat if necessary withaquarteradjustmentthistime Once the thermostat is set at the desired comfort setting do not touc...

Страница 8: ...itchtoselect1hr 2hrortostoptheunheatedventilation Whenthecycleisfinished theunheatedventilationindicatorlightremainson Tostarttheunheatedventilationagain pressthetimerswitchfortheselectedduration To turn the unheated ventilation off press the On Off Turbo switch briefly shutting the heateroff TURBOMode Duringcolderperiods thisspecialsettingallowsyourDivatoactasa1500wattheaterwith thermostatcontrol...

Страница 9: ...romtheprotectivegrillsituatedatthebackofyourDIVA NEVER USE ABRASIVE OR ACETONE BASED PRODUCTS TO CLEAN YOUR HEATERASTHISMAYDETERIORATETHEEPOXYFINISH ANY REPAIR ON YOUR CONVECTAIR HEATER SHOULD ONLY BE DONE BY A QUALIFIED TECHNICIAN AND ONLY AFTER THE HEATER HAS BEEN DISCONNECTED Your CONVECTAIR heater will become hot when in use Caution is advised when young children are present Do not insert smal...

Страница 10: ...on the lower right hand side of the heater same side as the thermostat It includes The complete model number and its production reference number A that must be included in any warranty claim Capacity B Standard certification C 2yearsagainstalldefects 5years onheatingelement All CONVECTAIR heaters are subject to a double warranty 2 years on all parts and manufacturing defects and 5years on the heat...