Contura C i4 FS Скачать руководство пользователя страница 8

GB

8

Supply of combustion air

When a stove is installed in a room, the demand for air supply to 
the room increases. Air can be provided indirectly via a vent in the 
outer wall or via a duct from the outside that is connected to the 
stove. The amount of air needed for combustion is approximatly 
20m³/h.

Install supply air connector (accessory) and outside air-supply kit 
(accessory) before chimney installation.
Assembly instruction is found together with the accessory.

Outside air-supply kit (accessory)

Supply air connector (accessory)

 COMBUSTION AIR / ACCESSORY

Heat retaining – Powerstone

Place heat retaining Powerstone, before chimney installation 
(accessory).
Assembly instruction is found together with the accessory.

Содержание C i4 FS

Страница 1: ...Installation Instructions C i4 FS www contura eu For use in GB and IE only...

Страница 2: ...output 4 kW 4 kW Efficiency 78 76 Flue gas temperature in connector at nominal output 310 C 270 C EN 13240 2001 A2 2004 PRODUCT Product type Stove lit with solid biofuels Type designation Contura i4...

Страница 3: ...r glass Placing flammable material closer than the safe distance indicated may cause a fire Smouldering can cause quick gas ignition with the risk of damage to property and personal injury NOTE WARNIN...

Страница 4: ...s a draught in the chimney of at least 12 Pa The draught is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and a suitable...

Страница 5: ...ecting a steel flue please refer to the relevant manufacturer s installation instructions Observe the safety distances to combustible material that steel flues require Permitted area for combustible p...

Страница 6: ...at the building has enough bearing capacity for the hearth stove and chimney When top connecting a steel flue please refer to the relevant manufacturer s installation instructions Observe the safety d...

Страница 7: ...GB 7 PREINSTALLATION Prior to installation 10 10 VAN AD IUM No 7 CHROME LEK 10 10 VA NA DI UM No 7 CHRO M E...

Страница 8: ...ir needed for combustion is approximatly 20m h Install supply air connector accessory and outside air supply kit accessory before chimney installation Assembly instruction is found together with the a...

Страница 9: ...GB 9 SMOKE CONTROL AREA 1 1 2 2 In smoke control areas it is mandatory to stop the damper from closing completely In other areas it s optional Smoke control area Ci4 FS Classic Ci4 FS Modern...

Страница 10: ...stove Position the stove on the hearth plate Adjust the height of the four adjustable feet until the stove is horizontal Adjusting and connecting After the stove has been adjusted and positioned acco...

Страница 11: ...Fire box surround When sweeping the smoke baffle must be lifted out this can be done when one side has been dismantled Fire bars Lift the fire bars straight up clean the ash from the guide groove in...

Страница 12: ...ura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu NIBE AB Box 134...

Отзывы: