GB

4

WOOD

COAL

Handle 

(removable on modern)

FACTS

Building application

Before installing a stove or erecting a 
chimney it is necessary for you to apply 
for planning permission from your local 
authority. Ask your local authority for 
advice regarding building regulations and 
the application.

Technical data

Output 

3-5 kW

Nominal output  4 kW
Efficiency level  Up to 80%

Model Classic

Weight (kg) 

85

Width (mm) 

479

Depth (mm) 

408

Height (mm) 

642

Model Modern

Weight (kg) 

81

Width (mm) 

492

Depth (mm) 

368

Height (mm) 

660

The connector’s inner diameter is Ø126 mm
Type approved in accordance with:
European standard EN-13240

DEFRA exempted

The stove can be used in 
Smoke Control Areas.

Fire-box insulation panels

Grate

Ash-pan

Log guard

Type plate

Primary air

inlet control

Secondary air

inlet control

Chimney

Note!

 The stove installation and connection 

to a chimney must be accomplished with 
the current edition of Building Regulations. 
We recommend that you consult a local 
chimney sweep before the installation 
to make sure that the chimney is in good 
condition.
The stove is type approved and must be 
connected to a chimney dimensioned 
for at least 350°C. The connector on 
the appliance is suitable for pipes with 
diameter of 125 mm. The stove can be 
loaded with maximum 100 kg of chimney.

A flexible flue liner or steel flue 
certified for use with solid fuel is highly 
recommended. The stove requires a 
draught in the chimney of at least –12 
Pa. The draught is affected both by the 
length and area of the chimney, and by how 
well sealed it is. Minimum recommended 
chimney length is 3.5 m and a suitable 
cross section area is 120-175 cm² (125-
150 mm in diameter). Carefully check that 
the chimney is sealed and that there is 
no leakage around soot hatches and flue 
connections.

Note that a flue with sharp bends and 
horizontal routing reduces the draught in 
the chimney. Maximum horizontal flue is 1 
m, on the condition that the vertical flue 
length is at least 5 m. It must be possible 
to sweep the full length of the flue and the 
soot hatches must be easily accessible.

General

In this manual you will find instructions
about how your Contura i4 FS shall be 
installed. Before you start the installation 
it is important that you read this 
instruction carefully and fully understand 
the requirements. All European, national 
and local standards and regulations 
needs to be fulfilled when the appliance is 
installed.
To guarantee the function and safety of 
the stove we recommend that it is installed 
by a professional. Our Contura agents can 
recommend a suitable installer.

The room or space containing a stove shall 
have a permanent air supply sufficent to 
ensure proper combustion, to determine 
correct amount of air supply use current 
edition of Building Regulations.

Remember to use only for the appliance 
recommended fuel as wood logs 
or smokeless fuel as anthracite or 
manufactured smokeless fuel briquettes. 
Do not ever burn bituminous coal, “petro-
coke” or other petroleum based fuels!

Содержание C i4 FS

Страница 1: ...Installation Instructions C i4 FS www contura eu For use in GB and IE only...

Страница 2: ...output 4 kW 4 kW Efficiency 78 76 Flue gas temperature in connector at nominal output 310 C 270 C EN 13240 2001 A2 2004 PRODUCT Product type Stove lit with solid biofuels Type designation Contura i4...

Страница 3: ...r glass Placing flammable material closer than the safe distance indicated may cause a fire Smouldering can cause quick gas ignition with the risk of damage to property and personal injury NOTE WARNIN...

Страница 4: ...s a draught in the chimney of at least 12 Pa The draught is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and a suitable...

Страница 5: ...ecting a steel flue please refer to the relevant manufacturer s installation instructions Observe the safety distances to combustible material that steel flues require Permitted area for combustible p...

Страница 6: ...at the building has enough bearing capacity for the hearth stove and chimney When top connecting a steel flue please refer to the relevant manufacturer s installation instructions Observe the safety d...

Страница 7: ...GB 7 PREINSTALLATION Prior to installation 10 10 VAN AD IUM No 7 CHROME LEK 10 10 VA NA DI UM No 7 CHRO M E...

Страница 8: ...ir needed for combustion is approximatly 20m h Install supply air connector accessory and outside air supply kit accessory before chimney installation Assembly instruction is found together with the a...

Страница 9: ...GB 9 SMOKE CONTROL AREA 1 1 2 2 In smoke control areas it is mandatory to stop the damper from closing completely In other areas it s optional Smoke control area Ci4 FS Classic Ci4 FS Modern...

Страница 10: ...stove Position the stove on the hearth plate Adjust the height of the four adjustable feet until the stove is horizontal Adjusting and connecting After the stove has been adjusted and positioned acco...

Страница 11: ...Fire box surround When sweeping the smoke baffle must be lifted out this can be done when one side has been dismantled Fire bars Lift the fire bars straight up clean the ash from the guide groove in...

Страница 12: ...ura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu NIBE AB Box 134...

Отзывы: