Installation distance to walls
INSTALLATION DISTANCES
Ci4 FS Classic
Move the stove in position and check that the minimum installation
distances given in the diagrams are met. The minimum distance in
front of the stove opening to combustible parts of the building or
interior decoration must be at least 1 m. The appliance must stand on
a constructional hearth which meet the building regulations and has
minimum dimension as shown in the diagram. Always check that the
building has enough bearing capacity for the hearth, stove and chimney.
When top connecting a steel flue please refer to the relevant
manufacturer’s installation instructions. Observe the safety distances to
combustible material that steel flues require.
Permitted area for
combustible parts
of the building
* To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
125
Ø125
98
42
598
450
Constructional
Hearth
Combustible floor
Flue connector
479
642
408
304
100
673
740
779
450
Combustible wall
Constructional
Hearth
198
100
300
150
150
307
540
307
100
450
Combustible wall
Constructional
Hearth
254
50*
623
670
450
Constructional
Hearth
Fire-retardant wall of
brick or concrete
148
50*
50*
290
450
Constructional
Hearth
Fire-retardant wall of
brick or concrete