Installation distance to walls

INSTALLATION DISTANCES

Ci4 FS Modern

492

660

125

Ø125

98

42

616

450

Constructional

Hearth

Combustible floor

Flue connector

368

419

Move the stove in position and check that the minimum installation 
distances given in the diagrams are met. The minimum distance in 
front of the stove opening to combustible parts of the building or 
interior decoration must be at least 1 m. The appliance must stand on 
a constructional hearth which meet the building regulations and has 

minimum dimension as shown in the diagram.  Always check that the 
building has enough bearing capacity for the hearth, stove and chimney.
When top connecting a steel flue please refer to the relevant 
manufacturer’s installation instructions. Observe the safety distances 
to combustible material that steel flues require.

309

100

662

708

779

450

Combustible wall

Constructional

Hearth

197

100

300

150

150

540

450

307

307

100

Combustible wall

Constructional

Hearth

259

50*

612

670

450

Constructional

Hearth

Fire-retardant wall of

brick or concrete

147

50*

50*

297

450

Constructional

Hearth

Fire-retardant wall of

brick or concrete

* To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

Permitted area for 
combustible parts 
of the building

Содержание C i4 FS

Страница 1: ...Installation Instructions C i4 FS www contura eu For use in GB and IE only...

Страница 2: ...output 4 kW 4 kW Efficiency 78 76 Flue gas temperature in connector at nominal output 310 C 270 C EN 13240 2001 A2 2004 PRODUCT Product type Stove lit with solid biofuels Type designation Contura i4...

Страница 3: ...r glass Placing flammable material closer than the safe distance indicated may cause a fire Smouldering can cause quick gas ignition with the risk of damage to property and personal injury NOTE WARNIN...

Страница 4: ...s a draught in the chimney of at least 12 Pa The draught is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and a suitable...

Страница 5: ...ecting a steel flue please refer to the relevant manufacturer s installation instructions Observe the safety distances to combustible material that steel flues require Permitted area for combustible p...

Страница 6: ...at the building has enough bearing capacity for the hearth stove and chimney When top connecting a steel flue please refer to the relevant manufacturer s installation instructions Observe the safety d...

Страница 7: ...GB 7 PREINSTALLATION Prior to installation 10 10 VAN AD IUM No 7 CHROME LEK 10 10 VA NA DI UM No 7 CHRO M E...

Страница 8: ...ir needed for combustion is approximatly 20m h Install supply air connector accessory and outside air supply kit accessory before chimney installation Assembly instruction is found together with the a...

Страница 9: ...GB 9 SMOKE CONTROL AREA 1 1 2 2 In smoke control areas it is mandatory to stop the damper from closing completely In other areas it s optional Smoke control area Ci4 FS Classic Ci4 FS Modern...

Страница 10: ...stove Position the stove on the hearth plate Adjust the height of the four adjustable feet until the stove is horizontal Adjusting and connecting After the stove has been adjusted and positioned acco...

Страница 11: ...Fire box surround When sweeping the smoke baffle must be lifted out this can be done when one side has been dismantled Fire bars Lift the fire bars straight up clean the ash from the guide groove in...

Страница 12: ...ura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu NIBE AB Box 134...

Отзывы: