The performances stated in this sheet can be modifi ed without any prior notice

1

st

 Issue rev. b

04/2016

DBL462e

Page 7

STANDARD LEDs BEHAVIOUR

Lower eletronic board

Upper electronic board

LED

ULTRACAPACITORS STATUS

GREEN

ultracapacitors charged

RED

ultracapacitors discharging

OFF

ultracapacitors totally discharged

DIMENSIONS [mm]

234

194

86

122

LEDs behaviour

Actuator status

1

GREEN ON

The actuator arrived at the extreme point of the stroke

2

GREEN BLINKING

The actuator is moving or arrived at the intermediate point of the stroke

3

RED GREEN BLINKING 

ALTERNATING

Calibration or initialization phase

4

RED GREEN ON

Manual control enabled, the actuators ignores the control signal.

 

ATTENTION! The electronic board is electrically supplied

5

RED GREEN BLINKING 

SIMULTANEOUS

The actuator is in emergency return phase

177

194

122

RED LED (ultracapacitors status)

Ultracapacitors

GREEN LED (ultracapacitors status)

Содержание MVE2R Series

Страница 1: ...apacitors charging phase look at table on page 7 During this phase all the functions of the actuator are inhibited and the charge status of the ultracapacitors is signalled through 2 LEDs look at para...

Страница 2: ...uator link loose voltage supply out of range These faulty conditions are signalled via the GREEN and RED LED on the lower electronic board blinking accordingly see Diagnostic Alarm Function Table Cont...

Страница 3: ...red 2TGB F 3TGB F PN16 not required Controlli valves with threaded M40 connections except for VSB VMB VSBF VMBF PN16 AG51 VSB VMB VSBF VMBF PN16 AG52 AG63 Other manufacturers Siemens AG70 10 AG70 14 D...

Страница 4: ...mon SAFETY PRESCRIPTIONS 230 V products Install on the power supply line a protecting device to avoid short circuits fuse or magneto thermic according to the spec ifications in force in case of accide...

Страница 5: ...updates the stroke range if an unexpected mechanical stop is detected for at least 10s Manual Calibration the actuator calibration is started moving the DIP from OFF to ON or vice versa With DIP in ON...

Страница 6: ...ack to the initial position still signalling the anomaly until it is not within 60mm The actuator does not calibrate the stroke after 10s wrong range Valve with a stroke length longer than 60mm Remove...

Страница 7: ...aviour Actuator status 1 GREEN ON The actuator arrived at the extreme point of the stroke 2 GREEN BLINKING The actuator is moving or arrived at the intermediate point of the stroke 3 RED GREEN BLINKIN...

Отзывы: