background image

Document Ref: DV40APP/Rev2      09/02/2010 

Page 22  of  23                                  Raised byGG  Checked by JBJ__

 

Part No  Description 

 

 

 

2501/255 

45681-262 Loop sounder with isolating base (Apollo manufacture) 

2501/105 

55000-280 XP95 flame detector (Apollo manufacture) 

2501/381 

55000-852 XP95 sounder controller unit with isolator (Apollo manufacture) 

2501/285 

55000-812 Din rail zone monitor unit with isolator (Apollo manufacture) 

2501/375 

55000-843 XP95 switch monitor with isolator (Apollo manufacture) 

2501/377 

55000-841 XP95 switch monitor plus with isolator (Apollo manufacture) 

2501/373 

55000-847 XP95 I/O unit with isolator (Apollo manufacture) 

2501/371 

55000-849 XP95 output unit with isolator (Apollo manufacture) 

2501/382 

55000-589 XP95 3 channel I/O unit (Apollo manufacture) 

2501/383 

55000-588 XP95 3 channel I/O unit with isolator (Apollo manufacture) 

2501/253 

55000-885 XP95 Multi-Sensor (Apollo manufacture) 

2501/219 

55000-875 XP95 Mains Switching I/O Unit (Apollo manufacture) 

2501/378 

55000-845 XP95 Zone Monitor with Isolator (Apollo manufacture) 

2501/109 

58000-300 Discovery CO Detector (Apollo manufacture) 

2501/438 

55000-268 Reflective beam detector [5-50m] 

2501/439 

55000-273 Reflective beam detector [50-100m] 

2601/046 

55000-877 Loop Powered Beacon (Apollo manufacture) 

2601/031 

45681-265 Intelligent Base Sounder (Apollo manufacture) 

2601/063 

45681-278 Integrated Base Sounder (Apollo manufacture) 

 

Vesda Aspirating Smoke Detector 

2601/084 

46581-393 Discovery Sounder/Beacon Base (Apollo manufacture) 

2501/229 

55000-950 XP95 Weatherproof call-point (Apollo manufacture) 

2501/376 

55000-809 XP95 Switch Monitor Plus – Flush (Apollo manufacture) 

2501/590 

55100-908APO Call-point with isolator (Apollo manufacture) 

2501/622 

55000-760 XP95 Mini DIN Rail Switch Monitor (Apollo manufacture) 

2601/034 

45681-276 Anciliary base sounder (Apollo manufacture) 

2601/041 

55000-278 High output loop sounder (Apollo manufacture) 

2601/064 

45681-277 Integrated base sounder with isolator (Apollo manufacture) 

2601/065 

45681-331 Integrated base sounder/beacon (Apollo manufacture) 

2601/066 

45681-330 Integrated base sounder/beacon with isolator (Apollo manufacture) 

2601/069 

55000-274 Stand-alone high output sounder/beacon (Apollo manufacture) 

2601/070 

55000-291 Multi-tone open area sounder/beacon (Apollo manufacture) 

2601/071 

55000-293 Multi-tone open area sounder/beacon with isolator (Apollo manufacture) 

2601/072 

55000-296 Multi-tone open area sounder/beacon weatherproof (Apollo manufacture) 

2601/073 

55000-291 Multi-tone open area sounder/beacon with isolator, weatherproof (Apollo 
manufacture) 

2601/074 

45681-333 Beacon base with isolator (Apollo manufacture) 

2601/075 

45681-335 Beacon base (Apollo manufacture) 

2601/076 

55000-001APO Open area SONOS sounder (Apollo manufacture) 

2601/078 

55000-005APO Open area SONOS sounder/beacon (Apollo manufacture) 

2601/082 

58000-005 Discovery open-area sounder/beacon (Apollo manufacture) 

2608/001 

XPA-CB-1-2034 Optical smoke detector and address module (Apollo manufacture) 

2608/002 

XPA-CB-1-2032 Multisensor smoke detector and address module (Apollo 
manufacture) 

2608/003 

XPA-CB-1-1170 A1R heat detector and address module (Apollo manufacture) 

2608/004 

XPA-CB-1-1171 CS heat detector and address module (Apollo manufacture) 

2608/010 

XPA-IN-1-4007 XPander interface module with isolator (Apollo manufacture) 

2608/005 

XPA-MC-1-4006 XPander manual call-point (Apollo manufacture) 

Содержание 2604010

Страница 1: ...e 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1 0 Introduction and Typical System Illustration 2 2 0 Cabinet Specifications 4 3 0 Hardware Specifications 7 4 0 Soft...

Страница 2: ...st with cable installation The panel has a 4 line x 20 character backlit LCD display showing device address zone type status and location text The LCD display provides capacity for 40 characters of us...

Страница 3: ...7 A1445 APOLLO A1446 A1444 A1445 TRANSLATOR EXTINGUISHING SYSTEM CONVENTIONAL FIRE PANEL FIRE DAMPER MONITORING BEAM DETECTOR RELAY OUTPUT UNIT MINI SWITCH MONITOR WITH INTERRUPT REMOTE INDICATOR BARR...

Страница 4: ...410w x 144d Space for printer and 2 x 12V 12Ah battery set 2604011 96 Zone 40 Character Discovery 2 loop analogue addressable control panel with 96 zone LEDs c w 2 loop cards expandable to 4 loops wit...

Страница 5: ...inserts Cabinet size 480h x 410w x 144d Space for printer and 2 x 12V 12Ah battery set 2604020 96 Zone 40 Character Discovery 3 loop analogue addressable control panel with 96 zone LEDs c w 3 loop ca...

Страница 6: ...eans of pinch bolts thus avoiding the need to drill the cabinet 1 4 loop Repeaters Hole Height a 487mm 377mm Hole Width b 417mm 332mm Hole Depth c 114mm 76mm Max Bezel Height d 543mm 433mm Max Bezel W...

Страница 7: ...stomer s specification 2501 154 Fully flush stainless steel bezel for 96 Zone 40 Character Discovery 1 4 loop panel large repeater panel 2500 844 brushed or polished 2501 155 Fully flush brass bezel f...

Страница 8: ...2010 Page 8 of 23 Raised by GG Checked_ _JBJ 3 0 Hardware Specifications 3 1 Mechanical Assembly Illustration DISPLAY BATTERY SET SEE BATTERY CALCULATION SPREADSHEET PRINTER MOTHERBOARD LOOP CARDS CA...

Страница 9: ...40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 86 87 88 89 90 91 92 93 94 85 95 96 EN54 4 1997 EN54 2 1997 LPCB...

Страница 10: ...ted continuous if all active faults have been silenced Pulses if fault detected with either alarm circuit or any loop alarm controller Continuous for a silenced fault and alarm circuit disabled condit...

Страница 11: ...28V 1 0V CF I2 FAULT COMPUTER INTERFACE 0V NO P KEYBOARD NO NC P FIRE 1 NO FIRE 2 NC P J12 ALM 1 NC ALM 2 O1 I1 O1 I1 O2 O2 I2 FID2 LOOP 3 LOOP 2 LOOP 4 J13 J14 J15 O4 O3 I2 O3 I3 I3 I4 O4 I4 LOOP 1 L...

Страница 12: ...in Figure 1 although there is no limit to the number of switches Power supply status indicators OUTPUT OK Output healthy BATT CHARGE FAULT Battery or charger fault EARTH FAULT Short circuit between ea...

Страница 13: ...ed To prevent damage to the control panel bells must also be suppressed a bell fit diodes as shown in Figure 2 The circuit must be terminated with a 3k9 end of line resistor END OF LINE 3k9 POLARISING...

Страница 14: ...arging current 1 5A Battery type 2 off 12V 12AH sealed lead acid standby battery Battery size 151mm x 98mm x 97 5mm Panel inputs Remote Fault Fully monitored circuit 3k9 EOL 680R active Remote Evacuat...

Страница 15: ...nd times set the delay duration and enable or disable the delay 4 1 3 Enabling Site Specific Data Changes All site specific data is held in non volatile memory To protect this from errors the memory i...

Страница 16: ...acon volume setting using magnetic wand Configure Discovery Sounder Beacon auto stop function 4 1 6 Zone Allocation The 96 Zone 40 Character Discovery has 96 programmable zones All loop devices can be...

Страница 17: ...Fire in a group or zone output cleared on reset Any two fires in a group or zone output cleared on silence alarms Any two fires in a group or zone output cleared on reset Alert in a group or zone outp...

Страница 18: ...EMENTS 1 PANEL SETUP 1 LOOP SETUP 1 LOOP CONFIGURATION 1 LOOP CONTENTS 1 VIEW LOOP CONTENTS 2 PRINT LOOP CONTENTS 3 RECONFIGURE LOOP 2 POINT SENSITIVITY 1 FIRE 2 ALERT 2 ZONE ALLOCATION 1 EDIT POINT Z...

Страница 19: ...223 Enclosure c w 5A psu space for 6 2AH battery set 2 or 4 panel programmable expansion boards A1535 or A1536 2500 107 Printer 2500 198 1A 24V DC door retainer power supply unit in enclosure no batte...

Страница 20: ...mm high 15Ah battery 12V 181mm long x 98mm wide x 167mm high 38Ah battery 12V 166mm long x 175mm wide x 125mm high 65Ah battery 12V 350mm long x 166mm wide x 174mm high 6 0 Compatible Field Devices Th...

Страница 21: ...238 A1446 sounder outstation board 3 inputs 1 sounder circuit 1 relay 2500 240 A1447 add on zone monitor board for above outstation boards 2501 149 Enclosure to fit 1 outstation board Size 150h x 225...

Страница 22: ...tor Plus Flush Apollo manufacture 2501 590 55100 908APO Call point with isolator Apollo manufacture 2501 622 55000 760 XP95 Mini DIN Rail Switch Monitor Apollo manufacture 2601 034 45681 276 Anciliary...

Страница 23: ...2501 055 Roshni Electronic Sounder 24 volts DC Shallow Base IP54 2501 048 Squashni Sounder and Base 2501 049 Cover Plate for Squashni Sounder 2501 056 White Bedhead Sounder 2501 043 Xenon flashing be...

Отзывы: