background image

Document Ref: DV40APP/Rev2      09/02/2010 

Page 20  of  23                                  Raised byGG  Checked by JBJ__

 

 
 

5.1.2 

A1535/A1536 8 Way Expansion Boards 

 
Up to 31 (A1535 & A1536) 8 way programmable expansion boards may be connected to each 1-4 
loop panel.   A special 2 door cabinet is available to house up to 4 enhancement boards (details on 
request). Up to 31 boards in total may be connected via an RS485 comms - for local expansion only. 
Local power is required for each board in addition to the RS485 comms link.   
 

WARNING:

  In order to conform to the requirements of BS5839 / EN54, the A1536 8 way alarm 

board must be used adjacent to the main panel.

 

 
The inputs and outputs are fully programmable within the panel’s cause/effect facility.  The output 
type (eg relays or alarm circuits) are determined by the board type chosen. The inputs may be 
monitored or non-monitored, or indication only.  
 

Please refer to A1535 8 Way Relay Board & A1536 8 Way Alarm Board documentation for further 
details.

 

 
5.2 

Battery Sizes  (YUASA) 

 

Battery Rating 

Battery Size 

3.2Ah battery 12V 

134mm long x 67mm wide x 64mm high 

6.2Ah battery 12V 

151mm long x 65mm wide x 97.5mm high 

12Ah battery 12V 

151mm long x 98mm wide x 97.5mm high 

15Ah battery 12V 

181mm long x 98mm wide x 167mm high 

38Ah battery 12V 

166mm long x 175mm wide x 125mm high 

65Ah battery 12V 

350mm long x 166mm wide x 174mm high 

 
 

6.0 

Compatible Field Devices

 

 

The 

96 Zone, 40 Character Discovery

 is compatible with the devices listed in this section.  

 
Field Device Order Codes & Descriptions 

 

Part No  Description 

 

 

 

2501/270 

58000-500 Discovery Ionisation smoke detector (Apollo manufacture) 

2501/271 

58000-600 Discovery Optical smoke detector (Apollo manufacture) 

2501/272 

58000-400 Discovery Heat detector (Apollo manufacture) 

2501/273 

58000-700 Discovery Multisensor (Apollo manufacture) 

2501/274 

58000-900 Discovery Manual call point (Apollo manufacture) 

2501/022 

55000-500 XP95 Ionisation smoke detector (Apollo manufacture) 

2501/023 

55000-600 XP95 Optical smoke detector (Apollo manufacture) 

2501/024 

55000-400 XP95 Temperature detector - standard (Apollo manufacture) 

2501/020 

45681-210 XP95 Base complete with address card (Apollo manufacture) 

2501/019 

55000-900 XP95 Manual call point (Apollo manufacture) 

2501/027 

55000-700 XP95 Isolator (Apollo manufacture) 

2501/026 

45681-211 XP95 Isolator base (Apollo manufacture) 

 

2501/218 

45681-321 XP95 Isolating base, 20 devices (Apollo manufacture) 

2501/021 

55000-401 XP95 Temperature detector - high temperature (Apollo manufacture) 

2501/275 

55000-818 XP95 Input/Output unit (Apollo manufacture) 

Содержание 2604010

Страница 1: ...e 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1 0 Introduction and Typical System Illustration 2 2 0 Cabinet Specifications 4 3 0 Hardware Specifications 7 4 0 Soft...

Страница 2: ...st with cable installation The panel has a 4 line x 20 character backlit LCD display showing device address zone type status and location text The LCD display provides capacity for 40 characters of us...

Страница 3: ...7 A1445 APOLLO A1446 A1444 A1445 TRANSLATOR EXTINGUISHING SYSTEM CONVENTIONAL FIRE PANEL FIRE DAMPER MONITORING BEAM DETECTOR RELAY OUTPUT UNIT MINI SWITCH MONITOR WITH INTERRUPT REMOTE INDICATOR BARR...

Страница 4: ...410w x 144d Space for printer and 2 x 12V 12Ah battery set 2604011 96 Zone 40 Character Discovery 2 loop analogue addressable control panel with 96 zone LEDs c w 2 loop cards expandable to 4 loops wit...

Страница 5: ...inserts Cabinet size 480h x 410w x 144d Space for printer and 2 x 12V 12Ah battery set 2604020 96 Zone 40 Character Discovery 3 loop analogue addressable control panel with 96 zone LEDs c w 3 loop ca...

Страница 6: ...eans of pinch bolts thus avoiding the need to drill the cabinet 1 4 loop Repeaters Hole Height a 487mm 377mm Hole Width b 417mm 332mm Hole Depth c 114mm 76mm Max Bezel Height d 543mm 433mm Max Bezel W...

Страница 7: ...stomer s specification 2501 154 Fully flush stainless steel bezel for 96 Zone 40 Character Discovery 1 4 loop panel large repeater panel 2500 844 brushed or polished 2501 155 Fully flush brass bezel f...

Страница 8: ...2010 Page 8 of 23 Raised by GG Checked_ _JBJ 3 0 Hardware Specifications 3 1 Mechanical Assembly Illustration DISPLAY BATTERY SET SEE BATTERY CALCULATION SPREADSHEET PRINTER MOTHERBOARD LOOP CARDS CA...

Страница 9: ...40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 86 87 88 89 90 91 92 93 94 85 95 96 EN54 4 1997 EN54 2 1997 LPCB...

Страница 10: ...ted continuous if all active faults have been silenced Pulses if fault detected with either alarm circuit or any loop alarm controller Continuous for a silenced fault and alarm circuit disabled condit...

Страница 11: ...28V 1 0V CF I2 FAULT COMPUTER INTERFACE 0V NO P KEYBOARD NO NC P FIRE 1 NO FIRE 2 NC P J12 ALM 1 NC ALM 2 O1 I1 O1 I1 O2 O2 I2 FID2 LOOP 3 LOOP 2 LOOP 4 J13 J14 J15 O4 O3 I2 O3 I3 I3 I4 O4 I4 LOOP 1 L...

Страница 12: ...in Figure 1 although there is no limit to the number of switches Power supply status indicators OUTPUT OK Output healthy BATT CHARGE FAULT Battery or charger fault EARTH FAULT Short circuit between ea...

Страница 13: ...ed To prevent damage to the control panel bells must also be suppressed a bell fit diodes as shown in Figure 2 The circuit must be terminated with a 3k9 end of line resistor END OF LINE 3k9 POLARISING...

Страница 14: ...arging current 1 5A Battery type 2 off 12V 12AH sealed lead acid standby battery Battery size 151mm x 98mm x 97 5mm Panel inputs Remote Fault Fully monitored circuit 3k9 EOL 680R active Remote Evacuat...

Страница 15: ...nd times set the delay duration and enable or disable the delay 4 1 3 Enabling Site Specific Data Changes All site specific data is held in non volatile memory To protect this from errors the memory i...

Страница 16: ...acon volume setting using magnetic wand Configure Discovery Sounder Beacon auto stop function 4 1 6 Zone Allocation The 96 Zone 40 Character Discovery has 96 programmable zones All loop devices can be...

Страница 17: ...Fire in a group or zone output cleared on reset Any two fires in a group or zone output cleared on silence alarms Any two fires in a group or zone output cleared on reset Alert in a group or zone outp...

Страница 18: ...EMENTS 1 PANEL SETUP 1 LOOP SETUP 1 LOOP CONFIGURATION 1 LOOP CONTENTS 1 VIEW LOOP CONTENTS 2 PRINT LOOP CONTENTS 3 RECONFIGURE LOOP 2 POINT SENSITIVITY 1 FIRE 2 ALERT 2 ZONE ALLOCATION 1 EDIT POINT Z...

Страница 19: ...223 Enclosure c w 5A psu space for 6 2AH battery set 2 or 4 panel programmable expansion boards A1535 or A1536 2500 107 Printer 2500 198 1A 24V DC door retainer power supply unit in enclosure no batte...

Страница 20: ...mm high 15Ah battery 12V 181mm long x 98mm wide x 167mm high 38Ah battery 12V 166mm long x 175mm wide x 125mm high 65Ah battery 12V 350mm long x 166mm wide x 174mm high 6 0 Compatible Field Devices Th...

Страница 21: ...238 A1446 sounder outstation board 3 inputs 1 sounder circuit 1 relay 2500 240 A1447 add on zone monitor board for above outstation boards 2501 149 Enclosure to fit 1 outstation board Size 150h x 225...

Страница 22: ...tor Plus Flush Apollo manufacture 2501 590 55100 908APO Call point with isolator Apollo manufacture 2501 622 55000 760 XP95 Mini DIN Rail Switch Monitor Apollo manufacture 2601 034 45681 276 Anciliary...

Страница 23: ...2501 055 Roshni Electronic Sounder 24 volts DC Shallow Base IP54 2501 048 Squashni Sounder and Base 2501 049 Cover Plate for Squashni Sounder 2501 056 White Bedhead Sounder 2501 043 Xenon flashing be...

Отзывы: