manualshive.com logo in svg
background image

Disclaimer

Control4

®

 makes no representations or warranties with respect to this 

publication, and specifically disclaims any express or implied warranties of 
merchantability or fitness for any particular purpose. Control4 reserves the 
right to make changes to any and all parts of this publication at any time, 
without any obligation to notify any person or entity of such changes.

Trademarks

Control4 and the Control4 logo are registered trademarks of Control4 
Corporation. Other product and company names mentioned in this 
document may be the trademarks or registered trademarks of their 
respective owners.

Legal Notice

Fraunhofer IIS and Thomson.

 MPEG Layer-3 audio coding technology 

license from Fraunhofer IIS and Thomson. Supply of this product does not 
convey a license nor imply any right to distribute content created with this 
product in revenue-generating broadcast systems (terrestrial, satellite, 
cable, and /or other distribution channels), streaming applications (via 
Internet, intranets, and/or other networks), other content distribution 
systems (pay-audio or audio-on-demand applications, and the like) or on 
physical media (compact discs, digital versatile discs, semiconductor 
chips, hard drives, memory cards, and the like). 

Decisionmark

 is the service provider of analog and digital TV off-air cable 

and satellite channel list.

Radio Locator

 is the service provider of AM/FM channel list.

© 2005-2007 All Media Guide, LLC 

provides

 

music and video recognition 

technology that provides cover art and related text that enriches the 
Control4 user interfaces.

Copyright 

Copyright © 2005-2007 Control4. All rights reserved. No part of this 
publication may be reproduced, photocopied, stored on a retrieval system, 
or transmitted without the express written consent of the publisher.

Contact Information

Control4 Corporation
11734 S. Election Road
Salt Lake City, UT 84020 USA
http://www.control4.com

Wireless Touch Screen——10.5”” Setup Guide
Part Number: 200-00045 Rev A
Hardware Model Number: C4-TSM10-G-B (Battery: C4-BAT 10.52-B)

Содержание C4-TSM10-G-B

Страница 1: ......

Страница 2: ...te cable and or other distribution channels streaming applications via Internet intranets and or other networks other content distribution systems pay audio or audio on demand applications and the lik...

Страница 3: ...iew 9 Top View 10 Left and Right Views 11 Back View 12 Modes 13 Chapter 2 Setting Up Wireless Touch Screen 15 Requirements 15 Install Battery Components 16 Connect to Power Supply 18 Calibrate the Tou...

Страница 4: ...peration Management 31 Chapter 4 Regulatory Compliance 33 FCC Information 33 FCC Interference Statement 33 FCC Caution 33 Canadian Standard Association CSA 34 Australian New Zealand 34 CE Declaration...

Страница 5: ...ially hazardous situation that if not avoided may result in death or serious injury DO NOT IGNORE A WARNING CAUTION This indicates a potentially hazardous situation that if not avoided may result in m...

Страница 6: ...2 Your authorized Control4 representative or reseller Control4 Web Site http www Control4 com...

Страница 7: ...r or adjustment is required WARNING To avoid data loss or equipment damage understand and follow these safety precautions before operating the Control4 Wireless Touch Screen Always use standard batter...

Страница 8: ...including this Control4 Wireless Touch Screen which ships with Control4 Navigator software pre installed NOTE For a complete list of supported devices see Products at http www Control4 com The Wireles...

Страница 9: ...5 Figure 1 1 Sample Wireless Access Point Setup...

Страница 10: ...diately if you find any missing or damaged component Control4 Wireless Touch Screen model C4 TSM10 G B which comes with Control4 Navigator software preinstalled AC Adapter AC Power Cord Battery Pack m...

Страница 11: ...lat panel Figure 1 2 Control4 Wireless Touch Screen 10 5 NOTE There are a variety of navigation interfaces for Control4 system users For a complete list contact a Control4 authorized reseller Specific...

Страница 12: ...ternal I O Connectors USB 2 0 Type A x2 Card slot PCMCIA Type II Card Bus type x 1 Audio Headphone terminal Microphone terminal User Indicators Power On Off Battery State RF Intensity Main Battery 3hr...

Страница 13: ...Button 5 Programmable Button 6 Programmable Button 7 Programmable Button 8 Direction Key 9 Selection Button 10 Touch Screen Table 1 2 Color Indication for LEDs Color Power LED Battery Charge LED WiFi...

Страница 14: ...can still be turned on as long as the AC adapter is plugged in Direction Key Use this cursor control to move the highlighter around the screen up down right and left Touch Screen Use this screen to p...

Страница 15: ...hut down press and hold for more than four seconds To place in Suspend mode quickly tap and release To resume operation from Suspend mode tap again Without the main battery pack the device cannot be t...

Страница 16: ...12 Back View View 1 Stand Up 1 Battery Pack 2 Battery Lock 3 Battery Release Latch 1 2 3...

Страница 17: ...old the power button for more than four seconds Wake is when the screen displays anything other than a screensaver Sleep or Stand By is when screen is dark or running a screensaver but wakes up when t...

Страница 18: ...14...

Страница 19: ...h Screen 10 5 requirements are A network WiFi 802 11b g wireless access point WAP already configured to communicate with a Control4 controller such as Media Controller See the control4 com web site fo...

Страница 20: ...Management on page 30 and Battery Pack Operating Instruction on page 31 NOTE In order to prevent accidental data loss the device can only powered on when the battery pack is in place The Control4 Touc...

Страница 21: ...NOTE The system will not power on if the battery lock is not in the locked position NOTE The device must be connected to a power supply as indicated in the next section for at least 2 5 hours for the...

Страница 22: ...end into an electrical outlet The power source can range from 100 to 240 Volts at 50 or 60 Hz 2 Turn on the Control4 Touch Screen by pressing the power button The system should turn on If it does not...

Страница 23: ...h the screen firmly and accurately at the point indicated by the crosshairs see the sample screen below 2 Repeat Step 1 for each of the 4 subsequent points indicated by the crosshairs Set Network Sett...

Страница 24: ...y if enabled ________________________ IP Addressing Requirements The default is DHCP with dynamic addresses If instead you need to use a static IP address you will need to provide a network IP address...

Страница 25: ...eyboard is displayed Enter the SSID which is case sensititve and then press Done 6c If WEP Key is enabled press the WEP Key button to select it and then press in the text box provided An on screen key...

Страница 26: ...e Network page press IP Address 7b Choose Assigned for static IP address 7c Press in the text box provided for the IP Address An on screen keypad is displayed Enter the static IP address for this devi...

Страница 27: ...ep mode 2 Within Composer in the System Design view on the project tree right pane highlight the room where the Wireless Touch Screen resides Then under My Drivers go to the User Interface section and...

Страница 28: ...t out of the wizard 6 Optional To further set up the Wireless Touch Screen configure the properties Modifiable properties include Backlight Level Allows you to set the light level of the backlight Bac...

Страница 29: ...enable it If you need the passcode contact your authorized Control4 reseller If you have the passcode go to Config Disable View enter the passcode then press Director to unselect it Now press the Dire...

Страница 30: ...n you want to control from the drop down list provided in the header You can now use the Wireless Touch Screen with the Control4 home automation system For more information refer to the Wireless Touch...

Страница 31: ...The wireless coverage is dependent on a number of factors including Distance from the access point Quality of access point Metal beams studs window frames Other wireless devices such as cordless phone...

Страница 32: ...mode refer to Modes on page 13 Tap on the screen to check if the display will activate Plug in the AC DC adapter to charge the battery The Control4 Wireless Touch Screen cannot be turned on when not c...

Страница 33: ...t all configurations and will require completing the setup process again The touch screen is damaged Contact the Control4 authorized reseller from whom you purchased the Wireless Touch Screen Network...

Страница 34: ...ry charge at 50 of capacity Once a battery is recharged up to 100 capacity the storage time will be longer Refer to the following table as a guideline When battery is charged at 50 of capacity If stor...

Страница 35: ...p dramatically It is called over discharge condition If the over discharge condition happens several times the battery cell becomes non functional and non recoverable The cell over discharge failure i...

Страница 36: ...32...

Страница 37: ...or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the...

Страница 38: ...rm certification to U S Standards This product has been tested to the requirements of and shown to be in compliance with the following requisite standards CLASS 3862 11 Information Technology Equipmen...

Страница 39: ...lectromagnetic compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 17 Specific conditions for 2 4 GHz wideband transmission sy...

Страница 40: ...llation cost The warranty is not valid in cases where damage was incurred due to misuse abuse incorrect repair or improper wiring or installation It does not cover incidental or consequential damage T...

Отзывы: