![Contrec 414Q Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/contrec/414q/414q_manual_2658171045.webp)
Switch Settings
The following are recommended switch settings for different input signal types.
Note, input types d and e are only available on Channel 1. Channel 2 is limited
to signal types a to c.
Input Signal Type
Input Terminals
Switch Settings
CH1
CH2
+
-
+
-
1
2
3
4
5
6
7
8
a. Logic Signal, CMOS,
Pulse
9
8
3
8
off off off off on off off
off
b. Open Collector or Reed
switch
9
8
3
8
off off off off on off on
off
c. Namur Proximity (set
DC out to 8 volts)
11 9 11 3
on
off on
on
on
on off
off
Channel 1 Only
d. Switch or Reed Switch
with debounce circuit
(200Hz max)
9
8
off off off off on off on
on
e. Coil (20mV P-P
minimum)
9
8
off on off off off off off
off
General Specification
Switching Threshold:
2.5 Volts (except for input type c and e)
Maximum Input Voltage:
50V peak
Input Impedance
Input type a:
100K on channel 1
10K on channel 2
Input types b & d:
10K
Input type c:
1K
Input type e:
100K
Input Circuits 43