![Contrec 414Q Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/contrec/414q/414q_manual_2658171038.webp)
Step
Display
Description
Text
Ref
8
FILTER
The filter constant for filtering the rate display .
3.4.2
1
No filtering.
to
99
Very heavy filtering.
9
TOTCON
A division factor to convert the totals to different
units from those used for rate (ie gallons/min and
barrels).
3.5
1
Rate and totals have the same engineering units.
x.xxxx
Other factors can be programmed between 0.01
and 2000.
10
t.dPt
Number of decimal points with which the
resettable total is displayed between 0 to 0.000.
11
A.dPt
Number of decimal points with which the
Accumulated (non resettable) total is displayed
between 0 to 0.000.
12
ACCESS
Front
No Acc
Enable access to calibration routine via the front
keyboard only.
Enable access via front keyboard.
Disable access via front keyboard.
36 Calibration