UNDERVIEW
REMOVE SCREW BEFORE
SLIDING OUT BLOWER
NOTE: USE VACUUM ATTACHMENT
WITH A SOFT BRUSH
FIGURE 5
4.5 FURNACE
APPEARANCE
The furnace exterior fi nish is a durable automotive like coating. It may be washed with mild soap if necessary.
Galvanized metal surfaces require no maintenance.
4.6 CLEANING
It is advisable to keep dust build-up on warm surfaces to a minimum, since dust, in some cases, can be a
combustible.
Dust build-up in the circulating fan can impair blower performance; therefore, reduce effi ciency.
The recovery coil is located immediately above the blower assembly. Over time, it may become coated with
dust. To clean the recovery coil:
1. Disconnect electrical power to the furnace.
2. Remove the blower access door
3. Remove the screws fastening the blower assembly to the blower division panel.
4. Unplug harness from blower division, junction box and remove thermostat wires (label wires to correct
position).
5. Pull the blower assembly out.
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION
.
ALWAYS VERIFY OPERATION AFTER SERVICING.
CAUTION
!
!
6. Once the blower assembly has been removed, the coils may be vacuumed with the soft brush attachment.
(Figure 5)
IMPORTANT:
Be careful not to bend the fi ns when cleaning. You may wish to leave this maintenance
procedure to your service technician.
W415-1080 / A / 08.28.13
UM
68
Содержание C97 Series
Страница 27: ...W415 1080 B 08 28 13 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES ...
Страница 28: ...W415 1080 A 08 28 13 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES ...
Страница 58: ...W415 1080 A 08 28 13 58 IOM IOM 23 0 SERVICE HISTORY ...
Страница 72: ...W415 1080 A 08 28 13 ...