4.0 ROUTINE MAINTENANCE BY HOMEOWNER
4.1 AIR
FILTER
DO NOT OPERATE YOUR FURNACE OR AIR CONDITIONER FOR EXTENDED PERIODS OF
TIME WITHOUT AN AIR FILTER.
CAUTION
!
!
A portion of the dust entrained in the air may temporarily lodge in the air duct runs and the supply registers.
Any recirculated dust particles will be heated and charred by coming into contact with the heat exchanger.
This residue will soil ceilings, walls, drapes, carpets, furniture, and other household articles.
DISCONNECT THE ELECTRICAL POWER TO THE FURNACE BEFORE ATTEMPTING ANY
MAINTENANCE. FAILURE TO DO SO MAY CAUSE ELECTRICAL SHOCK RESULTING IN
SEVERE PERSONAL INJURY OR DEATH.
Follow air fi lter manufacturer’s instructions for removing and cleaning the fi lter. Allow the fi lter to dry thoroughly
before reinstallation and never operate the blower fan with a wet fi lter. Consult your installation contractor or
service technician if you have any questions on fi lters.
IF CLEANING RATHER THAN REPLACING THE FILTER, UNLESS THE FILTER IS
THOROUGHLY WASHED AND DRIED, BE SURE THAT THE FILTER IS RE-INSTALLED
WITH THE AIRFLOW DIRECTION IDENTICAL TO ITS PREVIOUS USE. REVERSING
THE FILTER WILL CAUSE DUST TRAPPED WITHIN THE FILTER TO BREAK FREE AND
RECIRCULATE WITHIN THE DUCT SYSTEM.
CAUTION
!
!
4.2 LUBRICATION
The circulating air blower, and exhauster motors have sealed bearings. The bearings contain permanent
special purpose lubricants. Attempting to force common oil into the circulating and exhauster assembly motor
bearings will deteriorate the original lubricant and shorten bearing life.
WARNING
!
!
4.3 ROUTINE
EXAMINATION
IMPORTANT:
We recommend that your furnace and exhaust/combustion air vents be checked by a qualifi ed
service technician once a year.
It is good practice to give a quick inspection of your furnace each time you inspect or clean the air fi lter. Things
to check:
•
Check the furnace for obvious signs of deterioration.
•
Check the venting and combustion air piping to ensure that it is still fastened to the furnace. It should not
sag, and should have a ¼” (6 mm) per foot (305 mm) slope upwards, to the outside wall or termination.
•
There should be no water marks on the fl oor under the venting. Water marks may indicate a leaking pipe joint.
•
All ductwork should be secured to the furnace, and all ductwork should be solidly supported throughout the
heating system.
W415-1080 / A / 08.28.13
UM
66
Содержание C97 Series
Страница 27: ...W415 1080 B 08 28 13 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES ...
Страница 28: ...W415 1080 A 08 28 13 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES ...
Страница 58: ...W415 1080 A 08 28 13 58 IOM IOM 23 0 SERVICE HISTORY ...
Страница 72: ...W415 1080 A 08 28 13 ...