background image

4

W415-0380 / E / 08.31.12

3.4B

!

WARNING

• 

THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.

• 

ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED.

• 

Under no circumstances should this appliance be modifi ed.

• 

Do not operate appliance before reading and understanding operating instructions. Failure to operate 
appliance according to operating instructions could cause fi re or injury.

• 

Risk of burns. The appliance should be turned off and cooled before servicing.

• 

Do not install damaged, incomplete or substitute components.

• 

Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges 
may be sharp. 

• 

Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and 
operating the appliance. Never obstruct the front opening of the appliance.

• 

If the appliance shuts off, do not re-light until you provide fresh air. If appliance keeps shutting off, have it 
serviced. Keep burner and control compartment clean.

• 

Do not burn wood or other materials in this appliance.

• 

Children and adults should be alerted to the hazards of high surface temperature and should stay away to 
avoid burns or clothing ignition.

• 

Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, 
young children and others may be susceptible to accidental contact burns. A physical barrier is recommended 
if there are at risk individuals in the house. To restrict access to an appliance, install an adjustable safety gate 
to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.

• 

Due to high temperatures, the appliance should be located out of traffi c and away from furniture and 
draperies.

• 

Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot 
surfaces.

• 

Clothing or other fl ammable material should not be placed on or near the appliance.

• 

Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from 
hot surfaces. These screens and guards must be fastened to the fl oor.

• 

Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.

• 

It is imperative that the control compartments, burners and circulating blower and its passageway in the 
appliance are kept clean. The appliance should be inspected before use and at least annually by a qualifi ed 
service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding 
material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and other 
fl ammable vapours and liquids.

• 

Furniture or other objects must be kept a minimum of 4 feet away from the front of the appliance.

• 

Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician 
to inspect the appliance and to replace any part of the control system and any gas control which has been 
under water.

• 

Do not allow fans to blow directly into the appliance. Avoid any drafts that alter burner fl ame patterns.

• 

Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance.

• 

Carbon or soot should not occur in a vent free appliance as it can distribute into the living area of your home. 
If you notice any signs of carbon or soot, immediately turn off your appliance and arrange to have it serviced 
by a qualifi ed technician before operating it again.

• 

Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all 
plastic bags, these are not toys and should be kept away from children and infants.

• 

As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as 
well as having a Carbon Monoxide Detector installed in the same area to defend you and your family against 
Carbon Monoxide.

• 

If equipped, the screen must be in place (closed) when the appliance is in operation.

• 

Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance. 
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or 
damage to decorations, a T.V. or other electronic components.

2.0 INTRODUCTION

Содержание CVF42N

Страница 1: ...tely call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This is an unvented gas fired heater that uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilatio...

Страница 2: ... 12 4 1 MINIMUM CLEARANCE TO COMBUSTIBLES 13 4 2 MINIMUM MANTEL CLEARANCES 13 4 3 ALCOVE INSTALLATION 14 4 4 NAILING TAB INSTALLATION 14 5 0 FINISHING 15 5 1 GRATE INSTALLATION 15 5 2 LOG PLACEMENT 15 5 3 GLOWING EMBERS 17 5 4 CHARCOAL EMBERS 17 5 5 VERMICULITE 17 5 6 CHARCOAL LUMPS 17 5 7 HOOD 17 5 8 L42 LOUVRE INSTALLATION 18 5 9 LOGO PLACEMENT 18 6 0 OPTIONAL BLOWER INSTALLATION 19 7 0 OPERATIO...

Страница 3: ... 08 31 12 1 0 INSTALLATION OVERVIEW Louvres see L42 LOUVRE INSTALLATION section Logs see LOG PLACEMENT section Hood see HOOD section Logo see LOGO PLACEMENT section Rating Plate see RATING PLATE INFORMATION section ...

Страница 4: ...to protect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the appliance are kept clean The appliance should be inspected before use and at least annually by a qualifi...

Страница 5: ...Webshare installation_manuals mass_requirements pdf WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU WITH HEADACHE DIZZINESS AND OR NAUSEA IF YOU HAVE THESE SIGNS THE HEATER MAY NOT BE WORKING PROPERLY GET FRESH AIR AT ONCE HAVE HEATER SERVICED SOME PEOPLE PREGNANT WOMEN PERSONS WITH HEART OR LUNG DISEASE ANEMIA THOSE UNDER THE INFLUENCE...

Страница 6: ...ong must not be removed from the cord plug As long as the required clearance to combustibles is maintained the most desirable and beneficial location for the appliance is in the center of a building thereby allowing the most efficient use of the heat created The location of windows doors and the traffic flow in the room where the appliance is to be located should be considered If the appliance is ...

Страница 7: ... rating shall be reduced at the rate of 4 for each additional 1 000ft Expansion contraction noises during heating up and cooling down cycles are normal and to be expected No external electricity 110 volts or 24 volts is required for the gas system operation Expansion contraction noises during heating up and cooling down cycles are normal and are to be expected This appliance is only for use with t...

Страница 8: ...CESSORIES NOT APPROVED FOR USE WITH THIS HEATER IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTAINANCE CAN CAUSE PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE REFER TO THE OWNER S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS TOP SIDES B...

Страница 9: ...sed to the outside atmosphere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and B Weather stripping has been added on openable windows and doors and C Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall pane...

Страница 10: ...um BTU h 800x1000 16 000 BTU h 50 19 2 EXAMPLE 1 In this example because there is no door to the adjoining room the volume of the adjoining room may be added to the volume of the room with the heater to get a total unconfined space The total unconfined space 800 1200 2000 cubic feet Maximum BTU h 2000x1000 40 000 BTU h 50 If there are no more fuel burning appliances within this space then the 30 0...

Страница 11: ...MOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR ENSURE ADEQUATE VENTILATION FOR GAS AND ELECTRICAL LOCATIONS SEE DIMENSION SECTION ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE HIGH PRESSURE WILL DAMAGE VALVE DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GA...

Страница 12: ...ERIALS ARE SECURED WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO MAINTAIN CLEARANCES FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS LISTED MUST BE CONSTRUCTED ENTIRELY OF NON COMBUSTIBLE MATERIALS MATERIALS CONSISTING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE MATERIALS THAT ARE REPORTED AS PASSING ...

Страница 13: ...nstalla tions 4 1 MINIMUM CLEARANCE TO COMBUSTIBLES 4 2 MINIMUM MANTEL CLEARANCES Combustible materials may be installed flush with the front of the appliance but must not cover any of the black face areas of the appliance Non combustible material brick stone or ceramic tile may protrude in these areas Combustible mantel clearance can vary according to the mantel depth Use the graph to help evalua...

Страница 14: ...orner post to the nailing tab Once the nailing tab is in the desired location drill through the centre hole of the nailing tab Secure with a sheet metal screw Additional set screws may be installed NAILING TAB 4 4 NAILING TAB INSTALLATION APPLIANCE RECESS OR ALCOVE AREA NOTE Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are m...

Страница 15: ...all onto the two pins as illustrated WARNING LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE DO NOT MODIFY THE PROPER LOG POSITIONS SINCE APPLIANCE MAY NOT FUNCTION PROPERLY DELAYED IGNITION AND CARBON SOOT DISTRIBUTION THROUGHOUT THE LIVING AREA MAY OCCUR THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE DO NOT PLACE CHARCOAL EMBERS VERMICULITE OR CHARCOAL LUMPS ON THIS BURNER ALL...

Страница 16: ...log 5 against the centre grate post with the other end of the log resting in the pocket of log 4 4 5 6 E Place the bottom of the right crossover log 6 against the right tab of the log support and against the grate Place the top into the pocket provided on log 5 and allow to rest against the bracket of the log support REAR LOG SUPPORT LEFT TAB REAR TABS RIGHT TAB REAR TABS 1 A Prepare for log place...

Страница 17: ...ck the burner ports Blocked burner ports can cause an incorrect flame pattern Carbon deposits and delayed ignition PhazerTM logs glow when exposed to direct flame 5 3 GLOWING EMBERS 34 1 Place the lumps in front of the logs in a realistic manner taking care not to block any of the burner ports WARNING CHARCOAL EMBERS VERMICULITE AND CHARCOAL LUMPS ARE NOT TO BE PLACED ON THE BURNER WARNING APPLIAN...

Страница 18: ... into the slots lo cated at the bottom left and right corners of the unit To remove the louvres pull the back tabs of the clips forward while pushing the louvre assembly back Lift the clip 5 8 L42 LOUVRE INSTALLATION 5 9 LOGO PLACEMENT Remove the backing of the logo supplied and place on the screen cover as indicated LOGO D The curtain mesh must be kept fully closed during operation to help preven...

Страница 19: ...not previously equipped with a blower Route a grounded 2 wire 60hz power cable to the receptacle junction box At this point it must be strain relieved and insulated The three slots on the blower mounting bracket allow ease of adjustment when attaching the blower For a quiet running blower do not allow the assembly to sit on the firebox base Slide the vibration reducing pad A into the clip C and up...

Страница 20: ...turned on it will automatically start approximately 10 minutes after lighting the appliance and will run for approximately 30 45 minutes after the appliance has been turned off Use of the fan increases the output of heat Drywall dust will penetrate into the blower bearings causing irreparable damage Care must be taken to prevent drywall dust from coming into contact with the blower or its compartm...

Страница 21: ...of the back log G Turn gas knob counter clockwise to pilot H Depress and hold gas knob while lighting the pilot with the push button ignitor Keep knob fully depressed for one minute then release If pilot does not continue to burn repeat steps 3 through 7 With pilot lit turn gas knob counter clockwise to on When the pilot has been turned off ignition of the main burner may be delayed from 1 2 minut...

Страница 22: ...g Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER AIR SHUTTER OPENING VENTURI BURNER ORIFICE 49 1 AIR SHUTTER OPENINGS NG 3 16 LP 7 16 8 2 FLAME CHARACTERISTICS It s i...

Страница 23: ...y clean the burner and pilot assembly remove the logs rocks and or glass to expose both assemblies B Keep the control compartment media burner air shutter opening and the area surrounding the logs clean by vacuuming or brushing at least once a year C Check to see that all burner ports are burning Clean out any of the ports which may not be burning or are not burning properly D Check to see that th...

Страница 24: ...ION SENSOR SYSTEM 3 W680 0004 THERMOPILE 4 W725 0030 NATURAL GAS VALVE 4 W725 0031 PROPANE GAS VALVE 5 W385 0430 CONTINENTAL LOGO 6 GD 660 STANDARD WALL SWITCH 20FT OF WIRE 7 GL 633 LOG SET 8 W361 0079 GLOWING EMBERS 9 W550 0001 CHARCOAL EMBERS 10 W550 0002 CHARCOAL LUMPS 11 W361 0014 VERMICULITE 12 W135 0150 BACK LOG 1 9 2 CARE OF PLATED PARTS 6 1 If the appliance is equipped with plated parts yo...

Страница 25: ...IT POLISHED BRASS 30 L42SS LOUVRE KIT STAINLESS STEEL 15 12 22 24 30 14 13 7 23 29 19 18 21 20 2 4 17 16 COMPONENTS REF PART NO DESCRIPTION 13 W135 0151 SMALL LEFT LOG 2 14 W135 0152 SMALL RIGHT LOG 3 15 W135 0131 LEFT CROSSOVER LOG 4 16 W135 0132 CENTER LOG 5 17 W135 0133 RIGHT CROSSOVER LOG 6 18 W010 0864 PAN BURNER 19 W456 0038 38 NATURAL GAS BURNER ORIFICE 19 W456 0053 53 PROPANE GAS BURNER OR...

Страница 26: ... low Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure Pilot goes out when the gas knob is released The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled Allow approximately 60 seconds for the thermocouple to cool System is not correctly purg...

Страница 27: ...n Depletion Sensor System Call the gas distributor Pilot goes out while standing Main burner is in OFF position Gas piping is undersized Turn on all gas appliances and see if pilot flame flutters diminishes or extinguishes especially when main burner ignites Monitor appliance supply working pressure Check if supply piping size is to code Correct all undersized piping Pilot flame is not large enoug...

Страница 28: ...air shutter to specified opening see VENTURI ADJUSTMENT section Exhaust fumes smelled in room headaches Not enough combustion air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Not enough ventilation air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Flame is impinging on...

Страница 29: ...vironmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger brass trim or other components due to water w...

Страница 30: ...30 W415 0380 E 08 31 12 43 1 13 0 SERVICE HISTORY ...

Страница 31: ...31 W415 0380 E 08 31 12 14 0 NOTES 44 1 ...

Страница 32: ...32 W415 0380 E 08 31 12 ...

Отзывы: