9.0 OPTIONAL BLOWER INSTALLATION

THIS BLOWER IS NOT RECOMMENDED FOR THE 4 SIDED INSTALLATION

INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER

 and must be 

electrically connected and grounded in accordance with local codes.In the 
absence of local codes, use the current ANSI/NFPA 70 National Electrical Code 
in the United States. Remove the blower from its mounting bracket and attach to 
the bracket supplied with the appliance. This bracket is found secured on the 
mounting stud located at the bottom of the vent side wall.

Route a grounded 2-wire, 60Hz power cable to the 
junction box. At this point, it must be strained 
relieved and insulatied.

The blower bracket contains two 
holes that allow the blower to be 
positioned away from the intended 
gas supply hole.

Position the vibration reducing pad, centred, onto the threaded stud, piercing a hole 
into the pad. The blower must be able to be positioned entirely onto the pad.

 

Tilt the blower onto its side and slide it past the controls. Position the blower 

 

under the clip and onto the stud. Secure with a wing nut.

       

 

Remove 

the 

thermal 

switch 

 

 

 

 

 

 

  bracket from the top of the 

       

 

firebox. 

 

 

 

 

 

 

  Remove the thermal switch from the bracket supplied in the blower 

 

 

 

 

 

 

  kit and install the thermal switch into the appliance bracket. Then 

 

 

 

 

 

 

  replace  the bracket in the location it was removed.

 

 

 

 

 

 

  Connect the two ends of the unattached wires by the bracket to 

       

 

the 

thermal 

switch. 

 

 

 

 

 

 

  Connect the opposite ends of the wires to the red and black leads 

       

 

of 

the 

blower 

harness.

Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the recepticle.
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, 
preventing it from making contact with moving or hot objects.

black

white

red

VARIABLE
SPEED
SWITCH

BLOWER

THERMAL SWITCH

 VIBRATION
REDUCING PAD

WING NUT

     &

LOCK WASHER

!

WARNING

RISK OF FIRE AND ELECTRICAL SHOCK.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH 

THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS 

COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL 

VOID THE WARRANTY AND CERTIFICATION.

ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE 

APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER 

CORD BENEATH THE APPLIANCE.

THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN 

INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING 

CONTACT WITH MOVING OR HOT OBJECTS.

51.5

Содержание CVF40N

Страница 1: ...lding Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Страница 2: ...END INSTALLATION 15 5 1 FRAMING 15 5 2 BRICK PANEL INSTALLATION 16 5 3 FACING 16 5 4 FINISHING 16 6 0 SEE THRU INSTALLATION 17 6 1 FRAMING 17 6 2 BRICK PANEL INSTALLATION 18 6 3 FACING 18 6 4 FINISHIN...

Страница 3: ...VIEW Louvres see LOUVRE INSTALLATION section Hood see HOOD section Counter top see COUNTER TOP BAR INSTALLATION section Logs see LOG PLACEMENT section Bricks see BRICK PANEL INSTALLATION section Ratin...

Страница 4: ...o protect children from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the appliance It is imp...

Страница 5: ...2 GAS ELECTRICAL INLET 41 4 61 2 321 2 38 4 SIDED SEE THRU 36 401 2 271 2 221 8 221 8 21 2 GAS ELECTRICAL INLET 41 4 61 2 321 2 38 38 251 8 36 401 2 27 221 8 221 8 21 2 GAS ELECTRICAL INLET 41 4 61 2...

Страница 6: ...pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply pi...

Страница 7: ...AND BED SITTING ROOM INSTALLATION ALTITUDE INPUT REDUCED INPUT 0 2000 FT 0 610m 30 000 BTU h 20 000 BTU h 0 2000 FT 0 610m 28 500 BTU h 22 000 BTU h MODEL GVF40 N CVF400 N MODEL GVF40 P CVF400 P MANI...

Страница 8: ...owever if a problem should occur A Ensure sufficient combustion and circulation air B Use a dehumidifier C Do not use the unvented room appliance as a primary heat source WARNING IF THE AREA IN WHICH...

Страница 9: ...el burning appliances within this space then the 30 000 BTU h input of the appliance is suitable to be installed This also assumes that the construction of this space is not unusually tight 19 3 EXAMP...

Страница 10: ...provide sufficient movement for shifting the burner assembly on it s side to aid with servicing components F Check for gas leaks by brushing on a soap and water solution WARNING RISK OF FIRE EXPLOSION...

Страница 11: ...itch and replace with the leads from the wall switch millivolt thermostat 50 1 3 1 2 WARNING DO NOT CONNECT EITHER THE WALL SWITCH THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY 3 5 MOBILE H...

Страница 12: ...AIR SPACE CLEARANCE MAY CAUSE OVER HEATING AND FIRE PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS BLOCK OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN I...

Страница 13: ...irectly on of the top extension NOTE Maximum weight tolerance is 400 lbs provided that it is evenly distributed across the top extensions of the appliance In order to achieve a counter top or bar type...

Страница 14: ...ion with this appliance system When roughing in the appliance raise the appliance to accommodate for the thickness of the finished floor materials i e Tile carpeting hard wood which if not planned for...

Страница 15: ...USE OVER HEATING AND FIRE PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS BLOCK OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN IN INSULATION MAKE SURE INS...

Страница 16: ...ustible material brick stone or ceramic tile may protrude in these areas It is not necessary to install a hearth extension with this appliance system When roughing in the appliance raise the appliance...

Страница 17: ...TION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS BLOCK OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN IN INSULATION MAKE SURE INSU LATION AND OTHER MATERIALS ARE SECURED WHEN CONSTRUCTING THE ENCLOSU...

Страница 18: ...ombustible material brick stone or ceramic tile may protrude in these areas It is not necessary to install a hearth extension with this appliance system When roughing in the appliance raise the applia...

Страница 19: ...ACE CLEARANCE MAY CAUSE OVER HEATING AND FIRE PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS BLOCK OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN IN INSU...

Страница 20: ...not necessary to install a hearth extension with this appliance system When roughing in the appliance raise the appliance to accommodate for the thickness of the finished floor materials i e Tile car...

Страница 21: ...TC ARE CLEARLY MAINTAINED WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 WARNING LOGS MUST BE PLACED IN THEIR EXACT LOCATIO...

Страница 22: ...should rest in the groove on top of log 2 The slot in the underside of piece 3b fits over 3a Place the end of piece 3b onto the pin F As with log 1 log 4 is also cradled by the texture of the burner...

Страница 23: ...he base 5a slopes outwards between logs 2 and 4 As with pieces 3a b piece 5b fits over piece 5a Place the end of piece 5b onto the pin H The upper end of log 5 rests in the groove on top of log 4 and...

Страница 24: ...SHIELD STAND OFF REMOVAL Remove the backing of the logo supplied and place on the screen cover as indi cated 8 7 LOGO PLACEMENT A B C SLOT A B C CLIPS CENTRE SLOT TAB SLOT HINGE CLIP 57 2 UPPER LOUVR...

Страница 25: ...tall the thermal switch into the appliance bracket Then replace the bracket in the location it was removed Connect the two ends of the unattached wires by the bracket to the thermal switch Connect the...

Страница 26: ...electric power to the appliance Open the control door Turn the gas knob clockwise to off Wait five 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B in the above s...

Страница 27: ...UTTER IS IMPROPERLY ADJUSTED WARNING 49 5 This appliance has an air shutter that has been factory set open according to the chart below Regardless of venturi orientation closing the air shutter will c...

Страница 28: ...Verify proper operation after servicing This appliance and its venting system should be inspected before use and at least annually by a qualified service person The appliance area must be kept clear a...

Страница 29: ...T OF WIRE 3 W385 0430 CONTINENTAL LOGO 4 GL 657 BGD40 LOG SET 5 W135 0284 LOG 1 6 W135 0285 LOG 2 7 W135 0286 LOG 3 PIECE A 8 W135 0287 LOG 3 PIECE B 9 W135 0288 LOG 4 10 W135 0289 LOG 5 PIECE A 11 W1...

Страница 30: ...N 35 W010 2146 PAN BURNER 36 W475 0624 FIBRE BURNER COVER 37 W662 0001 NATURAL GAS OXYGEN DEPLETION SENSOR SYSTEM 37 W662 0005 PROPANE GAS OXYGEN DEPLETION SENSOR SYSTEM 38 W660 0005 BURNER ON OFF SWI...

Страница 31: ...31 W415 0857 B 02 14 11 7 23 25 24 36 32 22 31 28 34 8 9 6 10 11 5 16 21 18 17 20 27 33 30 41 42 4 37 14 12 15 13 25 35 43...

Страница 32: ...low Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure Pilot goes out when the gas knob is released The gas v...

Страница 33: ...Depletion Sensor System Call the gas distributor Pilot goes out while standing Main burner is in OFF position Gas piping is undersized Turn on all gas appliances and see if pilot flame flutters dimin...

Страница 34: ...of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Not enough ventilation air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applica...

Страница 35: ...s due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under the President s Limited Lifetime...

Страница 36: ...36 W415 0857 B 02 14 11 16 0 SERVICE HISTORY 43 1...

Отзывы: