35
W415-0889 / A / 08.11.10
7.1.1
Remove the control access panel.
7.1.2
Remove the door, see the section “DOOR REMOVAL / INSTALLATION”.
7.1.3
Carefully remove the log set and optional brick panels if installed, see section “LOG PLACEMENT”.
7.1.4
Remove the 2 screws holding the front grate in place.
7.1.5
Remove the 2 screws holding the rear log support.
7.1.6
Remove the 9 perimeter screws as illustrated and lift out the burner base assembly and gasket. (The
gas line
fl
ex-connector should provide suf
fi
cient movement to permit shifting the burner assembly on
it’s side).
7.1 ACCESSING THE BLOWER
7.0 OPTIONAL BLOWER INSTALLATION
!
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
CONTACT WITH MOVING OR HOT OBJECTS.
51.5
!
WARNING
BE CAREFUL NOT TO TEAR THE BURNER TRAIN GASKET. A REPLACEMENT GASKET CAN BE OR-
DERED FROM YOUR LOCAL AUTHORIZED DEALER / DISTRIBUTOR.
FRONT
GRATE
REAR LOG
SUPPORT
CONTROL ACCESS PANEL
PERIMETER SCREWS
Содержание CHDX40NT