3.0 fi nishing
6” (152mm) MANTEL
3”
4”
5”
12”
(305mm)
13”
(330mm)
14”
(356mm)
15”
(381mm)
TOP OF APPLIANCE
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed. These same requirements apply to any combustibles protruding on either side of the appliance.
0
$
1
7
(
/
+
(
,
*
+
7
3
4
5
6
MANTEL DEPTH
14" (356mm)
12" (305mm)
13" (330mm)
15" (381mm)
(76mm) (102mm) (127mm) (152mm)
3.1
minimum mantel clearances
!
WARNING
•
Risk of fi re!
•
Never obstruct the front opening of the appliance.
•
The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite,
etc., provided that these materials do not go below the specifi ed dimension, as illustrated.
•
Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, or scratched.
•
Facing and/or fi nishing material must never overhang into the appliance opening.
•
The glass door assembly is a safety device designed to pivot forward when relieving excess pressure that
might occur. Finishing or other materials must not be located in the opening surrounding the door as this will
interfere with the doors ability to relieve pressure.
•
If applicable, drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must
be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage
resulting from this condition is not covered by the warranty policy.
!
WARNING
•
Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions
may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
•
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.