background image

27

W415-0858 / A / 02.14.11

CONTINENTAL® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. 
Simply provide your proof of purchase along with the model and serial number to make a warranty claim. CONTINENTAL® reserves the right to 
have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the purchase was made through an 
authorized CONTINENTAL® dealer your appliance is subject to the following conditions and limitations:
Warranty coverage begins on the date of original installation. 
This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
The gas appliance must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance with the 
installation instructions included with the product and all local and national building and fi re codes.   This limited warranty does not cover damages 
caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and chemical cleaners 
nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers.
CONTINENTAL® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During 
the fi rst 10 years CONTINENTAL® will replace or repair the defective parts at our option free of charge. From 10 years to life, CONTINENTAL® will 
provide replacement burners at 50% of the current retail price.
In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided 
that the product has been operated in accordance with the operation instructions and under normal conditions.
After the fi rst year, with respect to this President’s Lifetime Limited Warranty, CONTINENTAL® may, at its discretion, fully discharge all obligations 
with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
CONTINENTAL® will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and such 
expenses are not covered by this warranty.
Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, CONTINENTAL’S responsibility under this warranty is defi ned 
as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defi nes the obligations and liability of CONTINENTAL® with respect to the CONTINENTAL® gas appliance and any other warranties 
expressed or implied with respect to this product, its components or accessories are excluded.
CONTINENTAL® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. 
CONTINENTAL® will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby 
trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may 
or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to appliance, combustion chamber, heat exchanger, brass trim or other components due to water, weather damage, long periods of 
dampness, condensation, damaging chemicals or cleaners will not be the responsibility of CONTINENTAL®.
All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim.
During the fi rst 10 years CONTINENTAL® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge.  
From 10 years to life, CONTINENTAL® will provide replacement parts at 50% of the current retail price.
All parts replaced under the warranty will be covered for a period of 90 days from the date of their installation.
The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim.  Returned products 
are to be shipped prepaid to the manufacturer for investigation.  If a product is found to be defective, the manufacturer will repair or replace such 
defect.
Before shipping your appliance or defective components, your dealer must obtain an authorization number.  Any merchandise shipped without 
authorization will be refused and returned to sender.
Shipping costs are not covered under this warranty.
Additional service fees may apply if you are seeking warranty service from a dealer.
Labour, travel, diagnostic tests, shipping and other related charges are not covered by this warranty.

2.8A

CONTINENTAL® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality 

Assurance Certifi cate.

CONTINENTAL® products are designed with superior components and materials assembled by trained craftsmen 

who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The 

complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the 

customer, receives the quality product that you expect from CONTINENTAL®.

The following materials and workmanship in your new CONTINENTAL® gas appliance are warranted against defects 
for as long as you own the appliance. This covers: combustion chamber, heat exchanger, stainless steel burner, 
phazer™ logs and embers, rocks, ceramic glass (thermal breakage only), gold plated parts against tarnishing, 
porcelainized enameled components and aluminum extrusion trims.*
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, switches, 
wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and CONTINENTAL® will provide 
replacement parts free of charge during the fi rst year of the limited warranty.*
Any labour related to warranty repair is not covered.
* Construction of models vary. Warranty applies only to components included with your specifi c appliance.

CONTINENTAL® GAS APPLIANCE PRESIDENT’S LIFETIME LIMITED WARRANTY

CONDITIONS AND LIMITATIONS

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUT TO ON-GOING PRODUCT IMPROVEMENTS. 

CONTINENTAL® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915 © WOLF STEEL 

LTD.

13.0 WARRANTY

Содержание CDI-30GN

Страница 1: ...gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installed as an OEM installation in manu...

Страница 2: ...Y INSTALLATION 13 5 4 MEDIA INSTALLATION 13 5 5 LOGO PLACEMENT 13 6 0 REPLACEMENT BLOWER INSTALLATION 14 7 0 OPERATION 15 7 1 OPERATING AND LIGHTING INSTRUCTIONS 15 7 2 ANTI CONDENSATION SWITCH 16 8 0...

Страница 3: ...INSTALLATION CHIMNEY CONNECTION section Glass see FINISHING GLASS BURNER INSTALLATION section Surround see FINISHING 4 SIDED SURROUND INSTALLATION section Door see FINISHING DOOR REMOVAL AND INSTALLAT...

Страница 4: ...ce is a vented gas fired appliance Do not burn wood or other materials in the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the applianc...

Страница 5: ...edroom or bathroom unless the unit is a direct vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED P...

Страница 6: ...blowers If an optional fan or blower is installed the junction box must be electrically connected and grounded in accordance with local codes use the current CSA C22 1 Canadian Electrical Code in Can...

Страница 7: ...SONT 10 PIEDS ET 35 PIEDS RESPECTIVEMENT MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 10 FEET AND 35 FEET RESPECTIVELY LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 10 PIEDS ET 35 PIEDS RESPE...

Страница 8: ...COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES USE WOLF STEEL LTD SUPPORT RING ASSEMBLY W010 0370 OR EQUIVALENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE...

Страница 9: ...p the one end of a liner a minimum of 2 over the sleeve of the air terminal Secure using 3 screws Then seal the joint and screw heads with high temperature sealant Repeat with the other liner NOTE We...

Страница 10: ...odes install to the cur rent CAN CSA B149 1 Installation Code in Canada or to the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States D When flexing any gas line support the gas va...

Страница 11: ...T MANTEL FRONT ETC ARE CLEARLY MAINTAINED WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 This insert must be recessed into...

Страница 12: ...ck on off switch wires already connected to the frame to the white and green wires located on the lower right hand side of the appliance control compartment B Connect the black light switch wire alrea...

Страница 13: ...ply push the media away from the burner ports NOTE The distribution of glass media over the burner tube will influence the flame height When the flames impinge on the glass the glass may discolour sli...

Страница 14: ...y activated when turned on it will automatically start approximately 5 15 minutes after lighting the appliance insert and will run for approximately 30 45 minutes after the appliance insert has been t...

Страница 15: ...URALA L ELECTRICITE CONSULTE LES INSTRUCTIONS D INSTALLATION A CET APPAREIL EST MUNI D UN DISPOSITIF D ALLUMAGE QUI ALLUME LA VEILLEUSE AUTOMATIQUEMENT N ESSAYE PAS D ALLUMER LA VEILLEUSE MANUELLEMENT...

Страница 16: ...harness before using the appliance Place near the IPI board Batteries not included NOTE If battery backup is used it must be connected to a 6 volt battery pack 7 2 ANTI CONDENSATION SWITCH This appli...

Страница 17: ...17 W415 0858 A 02 14 11 AC Adaptor To ON OFF switch located on the top right hand corner of manditory trim 8 1 NIGHT LIGHTTM WIRING DIAGRAM...

Страница 18: ...orifice insert a clean bag into a vacuum cleaner and vacuum out glass media Replacement glass media can be ordered from Wolf Steel Ltd 9 0 ADJUSTMENTS 9 1 PILOT BURNER ADJUSTMENT 9 2 VENTURI ADJUSTME...

Страница 19: ...opile as well as reaches the burner 5 Replace the cleaned logs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area 6 Check...

Страница 20: ...holding the lamp assembly shield C Compress the 3 retainer fins and lift out the lamp assembly Disconnect the wires D Replace lamp assembly by aligning key hole and snap into place Re connect the wire...

Страница 21: ...Place the door frame face down careful not to scratch the paint B Center the gasketed glass inside the door frame with the thick side of the gasket facing up C Bend the glass retainers located along t...

Страница 22: ...W725 0062 SIT VALVE NG 2 W725 0063 SIT VALVE LP 3 W456 0042 42 NATURAL GAS BURNER ORIFICE 3 W456 0054 54 PROPANE GAS BURNER ORIFICE 4 W010 1865 NATURAL GAS PILOT ASSEMBLY 4 W010 1866 PROPANE GAS PILO...

Страница 23: ...IES REF NO PART NO DESCRIPTION 1 F40 ON OFF REMOTE 1 F50 THERMOSTAT REMOTE 2 GD 660 REMOTE WALL SWITCH WITH 20 WIRE 3 W660 0026 TIMER BATTERY OPERATED 4 GI RB RISER BOX PAINTED BLACK 5 W175 0322 CONVE...

Страница 24: ...d into the module Check voltage of the transformer under load at the spade connections on the module with the ON OFF switch in the ON position Acceptable readings of a good transformer are between 6 2...

Страница 25: ...me rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood th...

Страница 26: ...ue lazy transparent flame Blockage in vent Remove blockage In really cold conditions ice buildup may occur on the terminal and should be removed To minimize this from happening again it is recommended...

Страница 27: ...ftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechan...

Страница 28: ...28 W415 0858 A 02 14 11 14 0 SERVICE HISTORY 43 1...