9

W415-0778 / D / 09.13.12

3.1  VENTING LENGTHS AND COMPONENTS

Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab 

venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and 

air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-

Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided 

with the venting components.

A starter adaptor must be used with the following vent systems and may be purchased from the 
corresponding supplier: 

For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation 
procedure found on the website for your venting supplier.

For vent systems that provide seals on the inner exhaust 

fl

 ue, only the outer air intake joints must be sealed using a 

red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent 

pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the appliance 

fl

 ue collar 

which must be sealed using the black high temperature sealant Mill Pac.

When using Wolf Steel venting components, use only approved Wolf Steel rigid / 

fl

 exible components with the following 

termination kits: wall terminal kit 

GD422-1

GD422R-1

, or 1/12 to 7/12 pitch roof terminal kit 

GD410

, 8/12 to 12/12 roof 

terminal kit 

GD411

fl

 at roof terminal kit 

GD412

 or periscope kit 

GD401

 (for wall penetration below grade). With 

fl

 exible 

venting, in conjunction with the various terminations, use either the 5 foot vent kit 

GD420

 or the 10 foot vent kit 

GD430

For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a 
minimum. 
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify 
that it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must 
not be combined.

These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run 

is 20 feet. The maximum allowable vertical vent length is 40 feet. The maximum number of vent connections is two 

horizontally or three vertically (excluding the appliance and the air terminal connections) when using 

fl

 exible venting.

Horizontal runs may have a 0” rise per foot however for optimum performance it is recommended that all horizontal 

runs have a minimum 1/4” rise per foot using 

fl

 exible venting. For safe and proper operation of the appliance, follow 

the venting instructions exactly.  

A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family 

dwellings and serves both dwellings. Local codes or regulations may require different clearances.

Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼” air gap 

all around between the inner liner and outer liner is required for safe operation. 

PART

5”/8”

SUPPLIER

WEBSITE

Duravent

W175-0170

Wolf Steel

www.duravent.com

Amerivent

5DSC-N2

American Metal

www.americanmetalproducts.com

Direct Temp

5DT-AA

Selkirk 

www.selkirkcorp.com

SuperSeal

5DDA

Metal-Fab

www.mtlfab.com

8.3

Содержание BCDV42N

Страница 1: ...ediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ...IGID VENT COMPONENTS 23 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION 23 4 3 2 EXTENDED HORIZONTAL AIR TERMINAL INSTALLATION 23 4 3 3 VERTICAL AIR TERMINAL INSTALLATION 24 4 4 MOBILE HOME INSTALLATION 25...

Страница 3: ...LOSURE CLEARANCES See the section FRAMING and MINIMUM MANTEL AND ENCLOSURE CLEARANCES for drywall or other combustible material See the sections VENTING and INSTALLATION See the sections INSTALLATION...

Страница 4: ...trol compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before use and at least...

Страница 5: ...vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPE...

Страница 6: ...eated The location of windows doors and the traffic flow in the room where the appliance is to be located should be considered If possible you should choose a location where the vent will pass through...

Страница 7: ...ENT SUPERIEUR 2 BACK ARRIERE 0 VENT BOTTOM EVENT INFERIEUR 1 MANTEL MANTEAU 5 VENT HEAT SHIELD PROTECTEUR DE CONDUIT D VACUATION1 MAXIMUM HORIZONTAL EXTENSION L EXTENSION HORIZONTALE MAXIMALE 5 SEE IN...

Страница 8: ...irestop vent pipe shield or attic insulation shield when penetrating interior walls floor or ceiling NOTE If for any reason the vent air intake system is disassembled reinstall per the instructions pr...

Страница 9: ...e venting in conjunction with the various terminations use either the 5 foot vent kit GD420 or the 10 foot vent kit GD430 For optimum flame appearance and appliance performance keep the vent length an...

Страница 10: ...TYPICAL VENT INSTALLATIONS 18 MAX 38 1 4 MIN PLUS RISE 35 1 2 40FT MAX 3FT MIN 16 MIN NOTE When terminating vertically the restrictor plate W500 0205 must be installed see RESTRICTING VERTICAL VENTS...

Страница 11: ...riscope kit to locate the air termination above grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum of 12 above grade The maximum all...

Страница 12: ...om an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The termin...

Страница 13: ...s the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 14 2 For the following symbols used in the venting...

Страница 14: ...HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT HT HR HO 4 5 2 7 7 2 FT HT VT 7 2 8 15 2 FT Formula 1 HT VT 7 2 8 Formula 2 HT VT 40 FT 15 2 40 Since both formulas are met this vent configurati...

Страница 15: ...45 elbow four 90 elbows 135 03 405 135 8 1 FT HT HR HO 5 5 8 1 13 6 FT HT VT 13 6 5 5 19 1 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 FT 23 1 FT 13 6 23 1 Formula 2 HT VT 24 75 FT 19 1 24 75 Since both...

Страница 16: ...elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example V1 5 FT V2 10 FT VT V1 V2 5 10 15 FT H1 3 FT H2 2 5 FT HR H1 H2 3 2 5 5 5 FT HO 03 one 45 three 90 elbows 135 03 45 2...

Страница 17: ...e this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 FT 15 9 40 Since only formula 2 is met this vent configuration in unacceptable and a new fireplace location or vent...

Страница 18: ...NECTION CANNOT SLIP OFF DO NOT CLAMP THE FLEXIBLE VENT PIPE RISK OF FIRE EXPLOSION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORT...

Страница 19: ...gainst the firestop top and secure the two together Adjust the assembly to ensure it is tight to the vent Secure firestop to wall This restricts cold air from being drawn into the room or around the a...

Страница 20: ...Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1 clearance between the vent pipe and any combustible material Try...

Страница 21: ...exterior wall and make weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be suppo...

Страница 22: ...air terminal connector is properly centred within the flashing giving a 3 4 margin all around Fasten to the roof Do not nail through the lower portion of the flashing Make weather tight by sealing wit...

Страница 23: ...using 3 self tapping screws Repeat using the outer rigid pipe C Insert the vent pipes through the firestop maintaining the required clearance to combustibles Holding the air terminal lettering in an...

Страница 24: ...f the air terminal connector Place the flashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly cent...

Страница 25: ...e to secure For free standing products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is rec...

Страница 26: ...PLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE...

Страница 27: ...NIMUMS LISTED MUST BE CONSTRUCTED ENTIRELY OF NON COMBUSTIBLE MATERIALS MATERIALS CONSISTING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE...

Страница 28: ...7 not supplied It is best to frame your appliance after it is positioned and the vent system is installed Use 2x4 s and frame to local building codes It is not necessary to install a hearth extension...

Страница 29: ...rature requirements the enclosure space around and above the appliance must be left unobstructed See VENTING section 2 2 38 1 4 MINIMUM PLUS RISE 10 3 1 4 45 1 2 2 0 IF NON COMBUSTIBLE FINISHING IS US...

Страница 30: ...stible mantel clearance can vary according to the mantel depth Use the graph to help evaluate the clearance needed Curtains above the appliance must not be positioned lower than the 5 distance require...

Страница 31: ...CRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED FACING AND OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING 72 1A WARNING GLASS MAY BE HOT DO N...

Страница 32: ...A Remove the upper louvres and open the glass door Remove the logs B Remove the two securing screws located on either firebox side C Place the left panel against the left side of the firebox ensuring...

Страница 33: ...studs located on the burner with the holes on the bottom of the logs C Place the bottom of the left crossover log W135 0300 onto the stud on the left side of the log support The top of the log should...

Страница 34: ...l will only glow when exposed to direct flame however care should be taken to not block the burner ports Blocked burner ports can cause an incorrect flame pattern Carbon deposits and delayed ignition...

Страница 35: ...Attach and secure the variable speed switch using the nut provided Plug the harness cord into the receptacle The wire harness provided in this kit is a universal harness When installed ensure that any...

Страница 36: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Страница 37: ...3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNER THERMOCOUPLE THERMOPILE 9 2 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the ch...

Страница 38: ...be obstructed A In order to properly clean the burner and pilot assembly remove the logs rocks and or glass to expose both assemblies B Keep the control compartment media burner air shutter opening a...

Страница 39: ...the finish and little maintenance is required just wipe clean as needed Prolonged high temperature burning with the door ajar may cause discolouration on plated parts NOTE The protective wrap on plat...

Страница 40: ...ING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMPONENTS REF NO PART NO DESCRIPTION 1 W357 0001 PIEZO IGNITER 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0800 NATURAL GAS PILOT ASSEMB...

Страница 41: ...38 W010 0453 ROOF SUPPORT 39 W263 0065 ROOF FLASHING W236 0066 W236 0067 ACCESSORIES REF NO PART NO DESCRIPTION 40 W573 0007 10 3OZ TUBE HIGH TEMP SEALANT 41 W175 0166 5 COUPLER 41 W175 0002 8 COUPLER...

Страница 42: ...KB35 VARIABLE SPEED SWITCH 57 GA 566 HOT AIR DISTRIBUTION KIT 58 W690 0005 THERMOSTAT 110V FOR USE WITH GA 566 ONLY 59 GA 70 EXTENSION KIT 5FT 60 GA 72 HOT AIR EXHAUST KIT 61 W175 0211 CONVERSION KIT...

Страница 43: ...valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals i...

Страница 44: ...on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER T...

Страница 45: ...eadaches Appliance is spilling Ensure exhaust bracket gasket seal Check door seal and relief flap seal Check for chimney blockage Check that chimney is installed to building code Room is in negative p...

Страница 46: ...caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pre...

Страница 47: ...47 W415 0778 D 09 13 12 14 0 SERVICE HISTORY 43 1...

Страница 48: ...48 W415 0778 D 09 13 12...

Отзывы: