Continental Fireplaces BCDV42N Скачать руководство пользователя страница 21

21

W415-0778 / D / 09.13.12

4.2.1 HORIZONTAL AIR TERMINAL INSTALLATION

A.

 

Stretch the inner 

fl

 ex pipe to the required length 

taking into account the additional length needed for 
the 

fi

 nished wall surface. Apply a heavy bead of the 

high temperature sealant W573-0007 Mill Pac (not 
supplied) to the inner sleeve of the air terminal. Slip the 
vent pipe a minimum of 2” over the inner sleeve of the 
air terminal and secure with 3 #8 screws. 

B.

 

Using the outer 

fl

 ex pipe, slide over the outer 

combustion air sleeve of the air terminal and 
secure with 3 #8 screws. Seal using high 
temperature sealant W573-0002 (not supplied).

C.

 

Insert the vent pipes through the 

fi

 restop 

maintaining the required clearance to 
combustibles. Holding the air terminal (lettering 
in an upright, readable position), secure to the 
exterior wall and make weather tight by sealing 
with caulking (not supplied).

D.

 

If more vent pipe needs to be used to reach 
the appliance, couple them together as 
illustrated. The vent system must be supported 
approximately every 3 feet for both vertical and 
horizontal runs. Use noncombustible strapping 
to maintain the minimum clearance to combustibles.  

The air terminal mounting plate may be recessed into the exterior 
wall or siding no greater than the depth of its return fl ange.

E.

 

The vent heat shield must be installed only when terminating 
horizontally. Remove the two screws nearest the vent collars on 
the top of the appliance. Align the vent heat shield (supplied) and 
secure. Adjust the vent heat shield to touch the 

fi

 restop spacer.

23.5A

HI-TEMP

SEALANT

#8 X 1/2” SELF DRILLING 

SCREWS & WASHERS

INNER COUPLER

OUTER COUPLER

OUTER 

FLEX PIPE

INNER 
FLEX PIPE

OUTER 

FLEX PIPE

SCREWS

#10x2"

      PIPE

2" OVERLAP

OUTER FLEX

INNER FLEX

    PIPE

HIGH TEMPERATURE

SEALANT

CAULKING

VENT
HEAT 

SHIELD

SCREWS

Содержание BCDV42N

Страница 1: ...ediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Страница 2: ...IGID VENT COMPONENTS 23 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION 23 4 3 2 EXTENDED HORIZONTAL AIR TERMINAL INSTALLATION 23 4 3 3 VERTICAL AIR TERMINAL INSTALLATION 24 4 4 MOBILE HOME INSTALLATION 25...

Страница 3: ...LOSURE CLEARANCES See the section FRAMING and MINIMUM MANTEL AND ENCLOSURE CLEARANCES for drywall or other combustible material See the sections VENTING and INSTALLATION See the sections INSTALLATION...

Страница 4: ...trol compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before use and at least...

Страница 5: ...vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPE...

Страница 6: ...eated The location of windows doors and the traffic flow in the room where the appliance is to be located should be considered If possible you should choose a location where the vent will pass through...

Страница 7: ...ENT SUPERIEUR 2 BACK ARRIERE 0 VENT BOTTOM EVENT INFERIEUR 1 MANTEL MANTEAU 5 VENT HEAT SHIELD PROTECTEUR DE CONDUIT D VACUATION1 MAXIMUM HORIZONTAL EXTENSION L EXTENSION HORIZONTALE MAXIMALE 5 SEE IN...

Страница 8: ...irestop vent pipe shield or attic insulation shield when penetrating interior walls floor or ceiling NOTE If for any reason the vent air intake system is disassembled reinstall per the instructions pr...

Страница 9: ...e venting in conjunction with the various terminations use either the 5 foot vent kit GD420 or the 10 foot vent kit GD430 For optimum flame appearance and appliance performance keep the vent length an...

Страница 10: ...TYPICAL VENT INSTALLATIONS 18 MAX 38 1 4 MIN PLUS RISE 35 1 2 40FT MAX 3FT MIN 16 MIN NOTE When terminating vertically the restrictor plate W500 0205 must be installed see RESTRICTING VERTICAL VENTS...

Страница 11: ...riscope kit to locate the air termination above grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum of 12 above grade The maximum all...

Страница 12: ...om an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The termin...

Страница 13: ...s the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 14 2 For the following symbols used in the venting...

Страница 14: ...HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT HT HR HO 4 5 2 7 7 2 FT HT VT 7 2 8 15 2 FT Formula 1 HT VT 7 2 8 Formula 2 HT VT 40 FT 15 2 40 Since both formulas are met this vent configurati...

Страница 15: ...45 elbow four 90 elbows 135 03 405 135 8 1 FT HT HR HO 5 5 8 1 13 6 FT HT VT 13 6 5 5 19 1 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 FT 23 1 FT 13 6 23 1 Formula 2 HT VT 24 75 FT 19 1 24 75 Since both...

Страница 16: ...elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example V1 5 FT V2 10 FT VT V1 V2 5 10 15 FT H1 3 FT H2 2 5 FT HR H1 H2 3 2 5 5 5 FT HO 03 one 45 three 90 elbows 135 03 45 2...

Страница 17: ...e this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 FT 15 9 40 Since only formula 2 is met this vent configuration in unacceptable and a new fireplace location or vent...

Страница 18: ...NECTION CANNOT SLIP OFF DO NOT CLAMP THE FLEXIBLE VENT PIPE RISK OF FIRE EXPLOSION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORT...

Страница 19: ...gainst the firestop top and secure the two together Adjust the assembly to ensure it is tight to the vent Secure firestop to wall This restricts cold air from being drawn into the room or around the a...

Страница 20: ...Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1 clearance between the vent pipe and any combustible material Try...

Страница 21: ...exterior wall and make weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be suppo...

Страница 22: ...air terminal connector is properly centred within the flashing giving a 3 4 margin all around Fasten to the roof Do not nail through the lower portion of the flashing Make weather tight by sealing wit...

Страница 23: ...using 3 self tapping screws Repeat using the outer rigid pipe C Insert the vent pipes through the firestop maintaining the required clearance to combustibles Holding the air terminal lettering in an...

Страница 24: ...f the air terminal connector Place the flashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly cent...

Страница 25: ...e to secure For free standing products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is rec...

Страница 26: ...PLY PIPE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE...

Страница 27: ...NIMUMS LISTED MUST BE CONSTRUCTED ENTIRELY OF NON COMBUSTIBLE MATERIALS MATERIALS CONSISTING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE...

Страница 28: ...7 not supplied It is best to frame your appliance after it is positioned and the vent system is installed Use 2x4 s and frame to local building codes It is not necessary to install a hearth extension...

Страница 29: ...rature requirements the enclosure space around and above the appliance must be left unobstructed See VENTING section 2 2 38 1 4 MINIMUM PLUS RISE 10 3 1 4 45 1 2 2 0 IF NON COMBUSTIBLE FINISHING IS US...

Страница 30: ...stible mantel clearance can vary according to the mantel depth Use the graph to help evaluate the clearance needed Curtains above the appliance must not be positioned lower than the 5 distance require...

Страница 31: ...CRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED FACING AND OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING 72 1A WARNING GLASS MAY BE HOT DO N...

Страница 32: ...A Remove the upper louvres and open the glass door Remove the logs B Remove the two securing screws located on either firebox side C Place the left panel against the left side of the firebox ensuring...

Страница 33: ...studs located on the burner with the holes on the bottom of the logs C Place the bottom of the left crossover log W135 0300 onto the stud on the left side of the log support The top of the log should...

Страница 34: ...l will only glow when exposed to direct flame however care should be taken to not block the burner ports Blocked burner ports can cause an incorrect flame pattern Carbon deposits and delayed ignition...

Страница 35: ...Attach and secure the variable speed switch using the nut provided Plug the harness cord into the receptacle The wire harness provided in this kit is a universal harness When installed ensure that any...

Страница 36: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Страница 37: ...3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNER THERMOCOUPLE THERMOPILE 9 2 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the ch...

Страница 38: ...be obstructed A In order to properly clean the burner and pilot assembly remove the logs rocks and or glass to expose both assemblies B Keep the control compartment media burner air shutter opening a...

Страница 39: ...the finish and little maintenance is required just wipe clean as needed Prolonged high temperature burning with the door ajar may cause discolouration on plated parts NOTE The protective wrap on plat...

Страница 40: ...ING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMPONENTS REF NO PART NO DESCRIPTION 1 W357 0001 PIEZO IGNITER 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0800 NATURAL GAS PILOT ASSEMB...

Страница 41: ...38 W010 0453 ROOF SUPPORT 39 W263 0065 ROOF FLASHING W236 0066 W236 0067 ACCESSORIES REF NO PART NO DESCRIPTION 40 W573 0007 10 3OZ TUBE HIGH TEMP SEALANT 41 W175 0166 5 COUPLER 41 W175 0002 8 COUPLER...

Страница 42: ...KB35 VARIABLE SPEED SWITCH 57 GA 566 HOT AIR DISTRIBUTION KIT 58 W690 0005 THERMOSTAT 110V FOR USE WITH GA 566 ONLY 59 GA 70 EXTENSION KIT 5FT 60 GA 72 HOT AIR EXHAUST KIT 61 W175 0211 CONVERSION KIT...

Страница 43: ...valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals i...

Страница 44: ...on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER T...

Страница 45: ...eadaches Appliance is spilling Ensure exhaust bracket gasket seal Check door seal and relief flap seal Check for chimney blockage Check that chimney is installed to building code Room is in negative p...

Страница 46: ...caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pre...

Страница 47: ...47 W415 0778 D 09 13 12 14 0 SERVICE HISTORY 43 1...

Страница 48: ...48 W415 0778 D 09 13 12...

Отзывы: