40
W415-1516 / A / 10.22.15
EN
TOP OF
APPLIANCE
WARNING
: Non-combustible facing material may protrude from the top, and/or sides of this appliance,
as illustrated [up to a maximum of 6” (152.4mm)]. Greater than 6” (152.4mm) protrusions are considered a
mantel and must meet the combustible mantel requirements.
71.4B
4" (102mm)
2" (51mm)
6" (152mm)
FRONT OF
APPLIANCE
4" (102mm)
2" (51mm)
NON-COMBUSTIBLE
FACING MATERIAL
0" (0mm)
FINISH
MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
FINISH MATERIAL
2" (51mm)
4" (102mm)
6" (152mm)
4" (102mm)
2" (51mm)
0" (0mm)
6.4 NON-COMBUSTIBLE FACING MATERIAL
APPLIANCE
RECESS OR
ALCOVE
AREA
NOTE:
Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.
71.2
ENCLOSURE
AREA
6.5 ALCOVE
CLEARANCES