34
W415-1516 / A / 10.22.15
EN
It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building
codes.
It is not necessary to install a hearth extension with this appliance.
When roughing in the appliance, raise the appliance to accommodate for the thickness of the
fi
nished
fl
oor
materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower
access door and the installation of many decorative
fl
ashing accessories.
Combustible materials may be installed
fl
ush with the front of the appliance but must not cover any of the black
face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
Minimum clearance to combustible construction from appliance and vent surfaces:
Combustible
Framing:
-
3 1/2" (89mm) from top of stand-offs
-
1" (25mm) to bottom and sides of the vent pipe*
-
2" (51mm) to top of the vent pipe*
Combustible Finishing:
-
0" to rear
-
0" to front face and sides, 6 1/2"(165mm) for top
-
17 1/4" (438mm) recessed depth
Rear Exit
-
40 1/2" (991mm) to enclosure top from base of the appliance
-
54" (1372mm) to ceiling from base of the appliance
Top Exit
-
49" (1245mm) to enclosure top from base of the appliance
-
54" (1372mm) to ceiling from base of the appliance
* BCDV36 HORIZONTAL VENT SECTIONS:
A minimum of 1" (25mm) at the bottom and sides and 2" (51mm)
at the top of the vent pipe on all horizontal runs to combustibles is required. Use
fi
restop spacer W010-1774
(supplied).
* BCDV36 VERTICAL VENT SECTIONS:
A minimum of 1" (25mm) all around the vent pipe on all vertical
runs to combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use
fi
restop spacer W500-0096 (not supplied).
6.1 INSTALLING
STAND-OFFS
These appliances are supplied with two standoffs. For
convenience, the standoffs have been shipped
fl
at and located on
the top at the front. Before framing ensure the standoffs are bent
up and screwed into place ensuring a height of 4.5" (144mm).
NOTE: The information and dimensions in this section
represent the minimum clearances to combustible material.
It is best to frame your appliance after it is positioned and the vent
system is installed. Use 2x4's and frame to local building codes.