EN
W415-2369 / C / 12.09.20
5
standard checklist
Installer, please fill out the following information:
Customer:
Address:
Date of Installation:
Location of appliance:
Installer:
Dealer/Distributor contact number:
Serial #:
Model:
Natural Gas:
CB46NTR
CB46NTRE
Propane:
CB46PTR
CB46PTRE
1.0 general information
When the appliance is installed at elevations above 4,500 ft (1371m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000 ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and are to be expected.
This appliance is approved for bathroom, bedroom, and bed-sitting room installations and is suitable for mobile
home installation.
PRODUCT CODES CB46NTR AND CB46PTR ONLY: No external electricity (110 volts or 24 volts) is
required for the gas millivolt system operation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales.
Certaines piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Rensei-
gnez-vous auprès de votre municipalité au sujet des directives de recyclage.
Las baterías deben desecharse de acuerdo con las leyes y regulaciones locales. Algunas baterías
pueden reciclarse, y es posible que su centro de reciclado local las acepte para desecharlas.
Consulte en su municipalidad sobre las instrucciones para el reciclado.
1.1 rates and efficiencies
For your satisfaction, this appliance has been test-fired to assure its operation and quality!
RATES AND EFFICIENCIES
NG
P
Altitude (FT)
0-4,500
Max. Input (BTU/hr)
22,000
Min. Inlet Gas Supply Pressure
4.5" (11mb) Water Column
11" (27mb) Water Column
Max. Inlet Gas Supply Pressure
7"* (17mb) Water Column
13" (32mb) Water Column
Manifold Pressure (Under Flow Conditions)
3.5" (9mb) Water Column
10" (25mb) Water Column