This menu allows you to select the programs assigned to each of the 3 program groups, edit the 10 built-in programs and 
edit the 250 scenes forming these programs.
The Evora-RL2R can be assigned to 3 different slave groups (via the Slave mode function in the Function menu).
The designated Master unit sends programs containing slave groups information.
Programs are sent in a loop as follows:

Slave units receive every program but only reacts to those assigned to their group.
A unit assigned to the Slave 2 group will only react to the Auto Pro Part 2 program.

7.8 Edit Program

Submenus

Values

Description

Select Program

Auto Pro Part1 = Program 1 ~ 10

Program 1

Auto Pro Part2 = Program 1 ~ 10

Program 2

Auto Pro Part3 = Program 1 ~ 10

Program 3

Allows you to assign one of the 10 built-in programs to each 
Auto Pro Part X

Edit Program

Program 1
Program 2
...
Program 10

• Pro Test
• Step 01 ~ 64 

Allows you to select the scenes assigned to each program.
Press ENTER to assign one of the available scenes to each 
step.
A single scene can be assigned to different steps.
Assign the 

End

 scene to the last step of the program to set the 

end of the program.
Use the 

Pro Test

 submenu to visualise the scenes assigned to 

the program you are currently editing.

Edit User mode A

Max Channel = XX
PAN = CHXX
...etc

Editing user mode A :
- Max Channel is the number of channels used.
- PAN = CHXX is the channel assigned to the PAN function.
As a channel cannot remain empty, when a function is 
moved to another channel, the former function occupying 
its channel will be assigned to it.

Edit User mode B

Max Channel = XX
PAN = CHXX
...etc

""

Edit User mode C

Max Channel = XX
PAN = CHXX
...etc

""

Auto Prog

Part 1

Auto Prog

Part 2

Auto Prog

Part 3

Auto Prog

Part 1

Auto Prog

Part 2

Auto Prog

Part 3

Содержание Evora RL2R

Страница 1: ...USER GUIDE 10215 Juillet 2014 Version 1 BARREL SCANNER WITH 2R LAMP...

Страница 2: ...Evora RL2R Barrel scanner with 2R lamp Page 2 English...

Страница 3: ...t 13 Long periods of non use Disconnect the unit s main power during long periods of non use 14 Liquids or objects penetration Do not let any object penetrate this product as it may result in electric...

Страница 4: ...DMX 512 11 13 or 18 DMX channels 3 modes Standard Basic or Expert Assignable patch to every channel 7 built in programs accessible via the DMX Music sensitive built in programs Automatic detection of...

Страница 5: ...ow you to browse through menus and change values 7 Navigation button Allow you to browse through menus and change values 8 Navigation button Allow you to browse through menus and change values 9 Navig...

Страница 6: ...internal optical system it is imperative that the lamps be replaced every 6000 hours This is done to protect the internal optical system as well as prevent accidental lamp explosion which could lead...

Страница 7: ...number on which the unit receives an incoming DMX signal sent by the DMX remote control The DMX addressing can be performed by programming the channel number via the display located on the base of the...

Страница 8: ...tically turn off When browsing through menus values in blue are values currently in use When entering a new value it will be written in red until you save changes by pressing ENTER 7 1 FUNCTION Submen...

Страница 9: ...he password is 038 Clean Last Run Allows you to reset the Last Run Time Lamp Time Password Password allowing you to reset the overall lamp running time Lamp Hours The password is 038 Clear Lamp Time A...

Страница 10: ...nts Tilt Reverse ON OFF Reverses TILT movements Mic Sensitivity 0 99 Configures the internal mic sensitivity when using the music sensitive mode Hibernation OFF 01m 99m 15m Sets a timer for the moving...

Страница 11: ...Shutoff time 02 60m 05m Timer after which the display shuts off when it remains inactive Display Reverse ON OFF Rotates the display on a 180 angle Key Lock ON OFF Locks the keyboard when it remains in...

Страница 12: ...hannel AUTO PAN etc Tests each function individually Manual Control AUTO XXX PAN XXX etc Controls each function manually Calibration Password Password to unlock calibration 050 PAN XXX TILT XXX Allows...

Страница 13: ...lows you to assign one of the 10 built in programs to each Auto Pro Part X Edit Program Program 1 Program 2 Program 10 Pro Test Step 01 64 Allows you to select the scenes assigned to each program Pres...

Страница 14: ...to 250 scenes Indicate the number of scenes you want to save precising the opening and ending scenes The opening scene selection uses the left and right arrow buttons The ending scene selection uses...

Страница 15: ...18 026 Colour 2 027 035 Colour 3 036 044 Colour 4 045 053 Colour 5 054 062 Colour 6 063 071 Colour 7 072 080 Colour 8 081 089 Colour 9 090 098 Colour 10 099 107 Colour 11 108 116 Colour 12 117 127 Col...

Страница 16: ...g 5 5 5 PAN 000 255 PAN movements on 315 6 6 6 TILT 000 255 TILT movements on 90 7 7 7 PAN and TILT movement speed 000 225 Max speed to min speed 226 235 Black out during movements 236 245 Black out d...

Страница 17: ...dimmer settings 11 11 16 Lamp management built in programs and resets 000 019 Regular colour changes 020 029 Linear colour wheel can create half colours 030 039 Linear gobo and color wheels can create...

Страница 18: ...rors may have various origins Sensors are used to set the motors in their default position Either the magnetic sensors are defective or the magnets have been displaced Problems might also come from a...

Страница 19: ...2R Barrel scanner with 2R lamp Page 19 English 12 Dimensions 11 Photometric datas 440 223 300 233 300 250 279 237 58 Ouverture 4 4 Intensit lux 42480 18690 10390 Diam tre m 0 63 0 93 1 23 Distance m 1...

Страница 20: ...s to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates a...

Отзывы: