Evora-RL2R
- Barrel scanner with 2R lamp
Page 6
English
1 -
Remove the 3 panel screws (labeled A, B, and C)
2 -
Slowly pull it backwards. Slowly pull it
backwards. Disconnect the two wires connected
to the lamp. Squeeze the lamp holding clips
together and lift the holder.
3 -
Inster the new lamp. Please make sure not to
touch the lamp with your bare fingers as it will
damage it. A fabric is supplied with the lamp
to manipulate it safely. Make sure the lamp is
positioned properly, the connection lugs must be
above the lamp.
4 -
Reassemble the fixation system and reconnect
the wires. Put the panel back.
The Evora-RL2R device use a Philips™ PLATINUM
2R
©
lamp
This lamp cannot be hot started. Once turned off,
please wait at least 10 minutes before turning it back
on.
This unit was designed to use a PHILIPS
™
PLATINUM 2R lamp.
The use of any other lamp voids the warranty.
Any damaged or disformed lamp must be
replaced.
For your safety and the life length of the unit the Philips® Platinum 2R Discharge lamps have their lifetime limited
to 6,000 hours.
Because of the nature of the extreme heat associated with the Platinum 2R lamp and the tight nature of the
internal optical system it is imperative that the lamps be replaced every 6000 hours. This is done to protect the
internal optical system as well as prevent accidental lamp explosion, which could lead to hot glass particles falling from the
fixture. Failure to change the lamps within 300 hours of operation will result in automatic shut down of the fixture’s electronics.
At 6000 hours the display will begin to flash “Replace The Lamp” and the lamp will flicker for the first five minutes of operation.
At this point the lamp has reached the maximum rated life and should be replaced immediately. The fixture will continue to
operate for an additional 300 hours, however the “Replace the Lamp” warning will continue to flash in the display. Keep in mind
that the flicker protection circuitry will only work for about 300 hours (lamp clock life of 6000-6300 hours). After 6300 hours the
fixture will no longer respond to DMX commands and immediately enter a hibernation mode that will electronically discontinue
all fixture functionality with the exception of a few menu commands. The fixture will continue to enter hibernation mode until the
lamp is replaced and the lamp clock has been reset. (Menu : Clear Lamp Time).
5 - Replacing the lamp
Please unplug the device and wait at let it
cool down for at least 1 hour before trying
to replace the lamp.