Evora-RL2R

 - Barrel scanner with 2R lamp

Page  6

English

1 -  

Remove the 3 panel screws (labeled A, B, and C)

2 -  

Slowly pull it backwards. Slowly pull it 
backwards. Disconnect the two wires connected 
to the lamp. Squeeze the lamp holding clips 
together and lift the holder.

3 -  

Inster the new lamp. Please make sure not to 
touch the lamp with your bare fingers as it will 
damage it. A fabric is supplied with the lamp 
to manipulate it safely. Make sure the lamp is 
positioned properly, the connection lugs must be 
above the lamp.

4 -  

Reassemble the fixation system and reconnect 
the wires. Put the panel back.

The Evora-RL2R device use a Philips™ PLATINUM 
2R

©

 lamp

This lamp cannot be hot started. Once turned off, 
please wait at least 10 minutes before turning it back 
on.

This unit was designed to use a PHILIPS

 PLATINUM 2R lamp.

The use of any other lamp voids the warranty.

Any damaged or disformed lamp must be 
replaced.

For your safety and the life length of the unit the Philips® Platinum 2R Discharge lamps have their lifetime limited 
to 6,000 hours.
Because of the nature of the extreme heat associated with the Platinum 2R lamp and the tight nature of the 
internal optical system it is imperative that the lamps be replaced every 6000 hours. This is done to protect the 

internal optical system as well as prevent accidental lamp explosion, which could lead to hot glass particles falling from the 
fixture. Failure to change the lamps within 300 hours of operation will result in automatic shut down of the fixture’s electronics.
At 6000 hours the display will begin to flash “Replace The Lamp” and the lamp will flicker for the first five minutes of operation. 
At this point the lamp has reached the maximum rated life and should be replaced immediately. The fixture will continue to 
operate for an additional 300 hours, however the “Replace the Lamp” warning will continue to flash in the display. Keep in mind 
that the flicker protection circuitry will only work for about 300 hours (lamp clock life of 6000-6300 hours). After 6300 hours the 
fixture will no longer respond to DMX commands and immediately enter a hibernation mode that will electronically discontinue 
all fixture functionality with the exception of a few menu commands. The fixture will continue to enter hibernation mode until the 
lamp is replaced and the lamp clock has been reset. (Menu : Clear Lamp Time).

5 - Replacing the lamp

Please unplug the device and wait at let it 
cool down for at least 1 hour before trying 
to replace the lamp.

Содержание Evora RL2R

Страница 1: ...USER GUIDE 10215 Juillet 2014 Version 1 BARREL SCANNER WITH 2R LAMP...

Страница 2: ...Evora RL2R Barrel scanner with 2R lamp Page 2 English...

Страница 3: ...t 13 Long periods of non use Disconnect the unit s main power during long periods of non use 14 Liquids or objects penetration Do not let any object penetrate this product as it may result in electric...

Страница 4: ...DMX 512 11 13 or 18 DMX channels 3 modes Standard Basic or Expert Assignable patch to every channel 7 built in programs accessible via the DMX Music sensitive built in programs Automatic detection of...

Страница 5: ...ow you to browse through menus and change values 7 Navigation button Allow you to browse through menus and change values 8 Navigation button Allow you to browse through menus and change values 9 Navig...

Страница 6: ...internal optical system it is imperative that the lamps be replaced every 6000 hours This is done to protect the internal optical system as well as prevent accidental lamp explosion which could lead...

Страница 7: ...number on which the unit receives an incoming DMX signal sent by the DMX remote control The DMX addressing can be performed by programming the channel number via the display located on the base of the...

Страница 8: ...tically turn off When browsing through menus values in blue are values currently in use When entering a new value it will be written in red until you save changes by pressing ENTER 7 1 FUNCTION Submen...

Страница 9: ...he password is 038 Clean Last Run Allows you to reset the Last Run Time Lamp Time Password Password allowing you to reset the overall lamp running time Lamp Hours The password is 038 Clear Lamp Time A...

Страница 10: ...nts Tilt Reverse ON OFF Reverses TILT movements Mic Sensitivity 0 99 Configures the internal mic sensitivity when using the music sensitive mode Hibernation OFF 01m 99m 15m Sets a timer for the moving...

Страница 11: ...Shutoff time 02 60m 05m Timer after which the display shuts off when it remains inactive Display Reverse ON OFF Rotates the display on a 180 angle Key Lock ON OFF Locks the keyboard when it remains in...

Страница 12: ...hannel AUTO PAN etc Tests each function individually Manual Control AUTO XXX PAN XXX etc Controls each function manually Calibration Password Password to unlock calibration 050 PAN XXX TILT XXX Allows...

Страница 13: ...lows you to assign one of the 10 built in programs to each Auto Pro Part X Edit Program Program 1 Program 2 Program 10 Pro Test Step 01 64 Allows you to select the scenes assigned to each program Pres...

Страница 14: ...to 250 scenes Indicate the number of scenes you want to save precising the opening and ending scenes The opening scene selection uses the left and right arrow buttons The ending scene selection uses...

Страница 15: ...18 026 Colour 2 027 035 Colour 3 036 044 Colour 4 045 053 Colour 5 054 062 Colour 6 063 071 Colour 7 072 080 Colour 8 081 089 Colour 9 090 098 Colour 10 099 107 Colour 11 108 116 Colour 12 117 127 Col...

Страница 16: ...g 5 5 5 PAN 000 255 PAN movements on 315 6 6 6 TILT 000 255 TILT movements on 90 7 7 7 PAN and TILT movement speed 000 225 Max speed to min speed 226 235 Black out during movements 236 245 Black out d...

Страница 17: ...dimmer settings 11 11 16 Lamp management built in programs and resets 000 019 Regular colour changes 020 029 Linear colour wheel can create half colours 030 039 Linear gobo and color wheels can create...

Страница 18: ...rors may have various origins Sensors are used to set the motors in their default position Either the magnetic sensors are defective or the magnets have been displaced Problems might also come from a...

Страница 19: ...2R Barrel scanner with 2R lamp Page 19 English 12 Dimensions 11 Photometric datas 440 223 300 233 300 250 279 237 58 Ouverture 4 4 Intensit lux 42480 18690 10390 Diam tre m 0 63 0 93 1 23 Distance m 1...

Страница 20: ...s to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates a...

Отзывы: