Hardware RAID Setup
—
VPC-3100-G Series Reference Manual
-
98
-
◆
Both storages are damaged.
Prepare two good storages, and then perform recovery.
◆
Rebuilding failed (with a reading error)
The reading of data from the copy source might fail during rebuilding. Perform repair in accordance
with the procedure described below.
CAUTION
This operation repairs sector errors, it does not recover data.
Lost data may lead to system instability, so carry out recovery as necessary.
Repairing procedure
1
With the power OFF, change the DIP switch on the mirror card to setting 1.
*For the switch setting, see
.
2
Connect only the existing storage (which will not be replaced) to the mirror card, and then turn
the power ON.
3
Check that the status is as shown below.
Mirror Card LED Status
DIP Switch
Setting 1
*See “
LED Status (page89)
”
*
With the DIP switch is setting 1, it is unable to start up Windows.
Therefore, checking with hwRaid cannot be performed.
4
Turn the power OFF, change the DIP switch on the mirror card to setting 2.
*Set the mirror card DIP switch in the same way as instructed in step 1 of this procedure.
5
Turn the PC power ON, then start up Windows.
Содержание VPC-3100-G Series
Страница 32: ...32 Hardware Setup This section describes how to install connect and set up the product...
Страница 44: ...44 BIOS Setup This section describes AMI s Setup program built into the FLASH ROM BIOS...
Страница 70: ...70 Software RAID Setup This section describes software mirroring RAID1 setup...
Страница 84: ...84 Hardware RAID Setup This section describes hardware mirroring RAID1 setup...
Страница 106: ...Appendix VPC 3100 G Series Reference Manual 106 3 With the Brackets for Horizontal Orientation Vertical Installation...
Страница 110: ...110 Replacement Parts for Maintenance This section lists replacement parts for maintenance of the product...