Hardware RAID Setup
—
VPC-3100-G Series Reference Manual
-
94
-
◆
Replacing two storages
Replace the two existing HDDs with good ones that you have prepared. Then, carry out recovery.
Regarding replacement of storage, refer to “Setting the Storage” in the “
(page32)“
Removing the Top Cover, the Front Cover, and the Riser Card Bracket
For details on OS recovery, “
” in this section.
If the OS is not installed on the mirroring storage, all you have to do is replace the storage.
CAUTION
After it is set up, the product status becomes the same as when the product was shipped from
CONTEC. The data on the good storages that you have prepared will be erased.
4.
Hot-Swapping
Hot-swapping is possible with this mirror card, enabling the user to replace storages while the OS is
up and running. Regarding replacement of storage, see “Setting the Storage” in the “
This function is useful when one storage has malfunctioned. However, if both storages are faulty, this
function cannot be used.
CAUTION
⚫
Before using the hot-swapping function to replace a storage, check the storage that you will
remove.
⚫
If one storage is malfunctioning, removing the storage that is functioning normally with the
power ON may lead to system damage.
⚫
Removing one storage while the two storages are functioning properly is not recommended.
Содержание VPC-3100-G Series
Страница 32: ...32 Hardware Setup This section describes how to install connect and set up the product...
Страница 44: ...44 BIOS Setup This section describes AMI s Setup program built into the FLASH ROM BIOS...
Страница 70: ...70 Software RAID Setup This section describes software mirroring RAID1 setup...
Страница 84: ...84 Hardware RAID Setup This section describes hardware mirroring RAID1 setup...
Страница 106: ...Appendix VPC 3100 G Series Reference Manual 106 3 With the Brackets for Horizontal Orientation Vertical Installation...
Страница 110: ...110 Replacement Parts for Maintenance This section lists replacement parts for maintenance of the product...