7. BIOS Setup
SPC-8450-LVA
71
Error initializing hard disk controller
Cannot initialize controller. Make sure the cord is correctly and firmly installed in the bus. Be sure the
correct hard drive type is selected in Setup. Also check to see if any jumper needs to be set correctly on
the hard drive.
Floppy disk controller error or no controller present
Cannot find or initialize the floppy drive controller. Make sure the controller is installed correctly and
firmly. If there are no floppy drives installed, be sure the Diskette Drive selection in Setup is set to
NONE.
Invalid EISA configuration
PLEASE RUN EISA CONFIGURATION UTILITY
The non-volatile memory containing EISA configuration information was programmed incorrectly or has
become corrupt. Re-run EISA configuration utility to correctly program the memory.
NOTE: When this error appears, the system will boot in ISA mode, which allows you to
run the EISA Configuration Utility.
Keyboard error or no keyboard present
Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys are being
pressed during the boot.
If you are purposely configuring the system without a keyboard, set the error halt condition in Setup to
HALT ON ALL, BUT KEYBOARD. This will cause the BIOS to ignore the missing keyboard and
continue the boot.
Memory address error at ...
Indicates a memory address error at a specific location. You can use this location along with the memory
map for your system to find and replace the bad memory chips.
Memory parity error at ...
Indicates a memory parity error at a specific location. You can use this location along with the memory
map for your system to find and replace the bad memory chips.
Memory size has changed since last BOOT
Memory has been added or removed since the last boot. In EISA mode use Configuration Utility to
reconfigure the memory configuration. In ISA mode enter Setup and enter the new memory size in the
memory fields.
Memory verify error at ...
Indicates an error verifying a value already written to memory. Use the location along with your system's
memory map to locate the bad chip.
Offending address not found
This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY ERROR
messages when the segment that has caused the problem cannot be isolated.