4. Each Component Function
PT-E831H, PT-E831HS User’s manual
23
(2) Grounding
(a) Where possible, ground the PT-E independently.
The grounding work is class D grounding (grounding resistance 100
Ω
or less)
(b) When independent grounding is impossible, use the joint grounding method marked (2) below.
Figure 4.9 Grounding method
(c) The size of grounding wires must be 2 mm
2
or more.
Use wire in which green and yellow color is combined for grounding wire.
The grounding point should be as near as possible to PT-E to minimize grounding cable length.
CAUTION
Do class D or higher grounding work to earth PT-E. In addition, do not share the grounding with
other equipment.
(3) Remark
For PT-E831 series, if use resume function, operation shifts to either mode below when power failure
or voltage drop occurring.
1) [Continue mode]: Keep operating for 10 minutes.
2) [Standby mode]: Keep standby state for 30 minutes. Standby state is released when power
restoring; and operation is restarted immediately from the state right before
power failure.
*Require the battery pack PT-E73BAT(Optional) if use resume function.
ON/OFF Switch: POWER SW
POWER SW is provided.
Содержание PT-E831H
Страница 1: ...IPC Series PANEL PC E Series PT E831H PT E831HS User s Manual CONTEC CO LTD...
Страница 7: ...vi PT E831H PT E831HS User s manual...
Страница 23: ...3 Hardware Setup 16 PT E831H PT E831HS User s manual...
Страница 69: ...6 Setting the Touch panel Driver 62 PT E831H PT E831HS User s manual...
Страница 83: ...7 Resume Function EPC System Monitor 76 PT E831H PT E831HS User s manual...
Страница 117: ...8 BIOS Setup 110 PT E831H PT E831HS User s manual...
Страница 122: ......