POW-AD22GY, POW-AD13GY User’s Manual
POW-AD22GY, POW-AD13GY
6
Installation Environment Requirements
Parameter
Requirement description
Ambient temperature
0 - 50ºC
Ambient Humidity
10 - 90%RH (No condensation)
Floating dust particles
Not to be excessive
Corrosive gases
None
Line-noise
AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
Noise
immunity
Static electricity
resistance
Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3)
10 - 57Hz/semi-amplitude 0.15mm, 57 - 150Hz/2.0G
Vibration
resistance
Sweep resistance
80minutes each in X, Y, and Z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Impact resistance
15G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C004-compliant, IEC68-2-27-compliant)
Grounding
Class D grounding (previous class 3 grounding)
Installation location
Installing to the DIN rail (the control boards,etc.) as the power supply dedicated to
the F&eIT.
I/O Connectors
Item
Description
Board connector
5.08mm pitch
12.0A rated current
Compatible plug
Laterally operable screw-in type
(MSTB2,5/3-STF-5,08 made by PHOENIX CONTACT Corp.)
Input
Compatible wires AWG 24 - 12
12.0A rated current
Board connector
3.5mm pitch
8.0A rated current
Applicable plug
Laterally operable screw-in type
(MC1,5/3-ST-3,5 made by PHOENIX CONTACT Corp.)
Output
Applicable wires
AWG 28 - 16
8.0A rated current