4. Function
DIO-32DM-PE
47
Sampling function
Sampling control
This product can obtain sampling data at fixed intervals using a sampling clock. The table below lists
the sampling clock, sampling start trigger, and sampling stop trigger factors.
Table 4.1. Sampling clock, starting trigger, stopping trigger
Item Factor
Contents
Internal clock
Internal clock (50ns to 107s)
25ns unit
External clock
Fall of external clock input (EXTCLK0)
(Maximum frequency response: 10 MHz)
Handshake
Fall of handshake signal (EXTREQ0)
Sampling clock
SC connector
Clock input from synchronization control connector
(Maximum frequency response: 5 MHz)
Software Software
command
Rise of external signal
Rise of external start signal (EXTSTART0)
Fall of external signal
Fall of external start signal (EXTSTART0)
Pattern match
When matched with the specified input pattern
Sampling
starting trigger
SC connector
Start signal from synchronization control connector
Software Software
command
Rise of external signal
Rise of external stop signal (EXTSTOP0)
Fall of external signal
Fall of external stop signal (EXTSTOP0)
Specified number of items
Termination when the specified number of items is reached
SC connector
Stop signal from synchronization control connector
Sampling
stopping trigger
Bus master transfer error
When FIFO buffer becomes full
-
The product obtains the first sampling data at the falling edge of the sampling clock signal after
input of the sampling start trigger. From then on, the product obtains sampling data in
synchronization with the sampling clock signal.
-
The product stops sampling upon input of the sampling stop trigger. The product does not obtain
sampling data when and after sampling is stopped.