24
WORK
6.
By activating the man present lever (6) the brushes begin to rotate and the squeegee starts
suction, in the versions with the solenoid valve only now is the solution emitted onto the brush.
7.
During the first metres, check there is sufficient solution and that the squeegee dries perfectly.
6
2. FORWARD MOVEMENTS
The traction of these machines is obtained by means of the brush which, working slightly inclined, is able
to drag the machine forwards. The brush bas must be lifted in order to move the machine by means of the
grip on the handlebar.
ATTENTION! When making even brief reverse movements, check the squeegee
is raised.
3. OVERFLOW DEVICE
The machine is fitted with a float which intervenes when the recovery tank is full, causing the suction tube
to close. In this case the recovery tank must be emptied by removing the cap of the rear discharge pipe
ATTENTION: you are advised to always wear protective gloves, to avoid the risk
of serious injury to your hands