LIST OF ALARMS
LOCK ALARMS
The alarms listed in the table below can be reset only be switching the machine off. They can entail the
immediate stopping of the entire machine or a part of it.
MANUAL RESET ALARMS
The alarms listed in the table below can be reset manually using the user interface. They can entail the
immediate stopping of the entire machine or a part of it.
AUTOMATIC RESET ALARMS
The alarms listed in the table below can be reset automatically when the problem is solved. They can
entail the immediate stopping of the entire machine or a part of it.
ALARM
NUMBER
DESCRIPTION
LOCK
MANUAL
AUT
OMA
TIC
AL_1: General
Memory Error
X
AL_2: General
Issue with Key
X
AL_3: General
Undervoltage
X
AL_4: General
Overvoltage
X
AL_5: General
Batt. Connection
X
AL_6: General
Dashboard Communication
X
AL_7: General
FFM Communication
X
AL_8: General
Communication Internal 1
X
AL_9: General
Communication Internal 2
X
AL_10: General
Enter Tag
X
AL_11: General
Invalid Tag
X
AL_12: General
Update in progress…
X
AL_13: General
Switch off
X
AL_14: General
Full recovery
X
AL_15: General
Brake fluid Reserve
X
AL_41: Function
Overtemperature
X
AL_42: Function
Power Board Damaged
X
AL_43: Function
Main Fuse Faulty
X
AL_44: Function
Main Contactor Faulty
X
AL_45: Function
Main Contactor Faulty- CC
X
AL_46: Function
Overcurrent Outputs Brushes 1-2-3
X
AL_47: Function
Overcurrent Outputs vacuum Cleaner 1-2
X
AL_48: Function
Overcurrent Outputs Water Pumps
X
AL_49: Function
Amperometric Output Brushes 1
X
AL_50: Function
Amperometric Output Brushes 2
X
AL_51: Function
Amperometric Output Brushes 3
X
AL_52: Function
Amperometric Output Vacuum Cleaner 1
X
AL_53: Function
Amperometric Output Vacuum Cleaner 2
X
AL_60: Function
Timeout Actuator 1
X
AL_61: Function
Amperometric Actuator 1
X
AL_62: Function
Overcurrent Actuator 1
X
AL_63: Function
Limit Switch Incorrect Actuator 1
X
AL_64: Function
Timeout Actuator 2
X
AL_65: Function
Amperometric Actuator 2
X
AL_66: Function
Overcurrent Actuator 2
X
AL_67: Function
Limit Switch Incorrect Actuator 2
X
AL_68: Function
Timeout Actuator 3
X
AL_69: Function
Amperometric Actuator 3
X
ALARM
NUMBER
DESCRIPTION
LOCK
MANUAL
AUT
OMA
TIC
AL_70: Traction
Overcurrent Actuator 3
X
AL_71: Traction
Limit Switch Incorrect Actuator 3
X
AL_80: Traction
Overtemperature
X
AL_81: Traction
Power Board Damaged
X
AL_82: Traction
Main Fuse Faulty
X
AL_83: Traction
Main Contactor Faulty
X
AL_84: Traction
Main Contactor Faulty- CC
X
AL_85: Traction
Overcurrent Traction Output
X
AL_86: Traction
Amperometric Output Traction
X
AL_87: Traction
Motor Reading
X
AL_88: Traction
Electric Brake Issue
X
AL_89: Traction
Pedal Faulty
X
AL_90: Traction
Pedal Pressed
X
AL_91: Traction
Encoder Fault
X
34