VTop Control Valves
M/VTOP-M/E ed. 01 2020
CAUSE
EXTERNAL ENVIRONMENT, ADDITIONAL LOADS
(Wind and Earthquake not applicable)
EFFECT
Deformation, structural failure
DANGER
Breakage and/or deformation of the body, leaking fluid
SOLUTION
1. Support all the connection tubing that weighs on the valve with specific structures and/or
supports.
2. The valves do not allow external loads
3. The support structures and the relevant anchorage and/or foundation tie rods must be
calculated in advance.
6 – ATEX ON REQUEST WITH SPECIAL ACTUATOR EXECUTION
7 – LIST OF RECOMMENDED SPARE PARTS
7.1 – COMPONENTS SUGGESTED FOR COMMISSIONING AND START-UP
-
BODY UNIT GASKETS SET composed of :
No. 1 compartment gasket
No.2 body gaskets (no. 1 Type 20VT – no. 2 Type 50VT )
No.1 packing package
-
PLUG SEAL CLASS VI SET composed of:
No. 1 soft seal ring
7.2 – COMPONENTS AFTER 2 YEARS OF OPERATION
-
COMPLETE TRIM composed of:
No. 1 compartment
No. 1 trim-plug with stem with any seals
No. 1 complete body gaskets set
No.1 packing package