11
4. Open the Ball Valve (in line with) as shown (see Figure 6)
5. Operate the pump handle until the pressure on the gauge reads approximately
450 PSI. Use caustion as the brake begins to release as the arbor bar will
begin to rotate. (Figure 7)
6. Disengage drive side pin by removing keeper pin and pulling out the drive pin.
(Figure 7 & 8)
7. Remove bearing retainer pin and lift hinged keeper to fully open position.
(Figure 9 & 10)
Figure 9. Remove Retainer Pin from Bearing
Keeper
Figure 10. Open Bearing Keeper to Fully
Open Position
Figure 7. Remove Keeper Pin from Drive Pin
Figure 8. Pull Out Drive Pin
Figure 6. Open Ball Valve
Figure 7. Pump Handle until Gauge Reads
450 PSI
Содержание Tesmec RS20
Страница 1: ...USER S GUIDE SAFETY MANUAL USER S GUIDE SAFETY MANUAL RS20 RS26 Reel Stand...
Страница 16: ...16 CONDUX TESMEC INC RS20 REEL STAND ASSY 20000LBS...
Страница 18: ...18 CONDUX TESMEC INC RS26 REEL STAND ASSY 26000LBS...
Страница 20: ...20 CONDUX TESMEC INC CHAIN DRIVE DETAIL REEL STAND ASSY...
Страница 22: ...22 CONDUX TESMEC INC CHAIN DRIVE DETAIL REEL STAND ASSY...
Страница 24: ...24 CONDUX TESMEC INC HYDRAULIC DRIVE REEL STAND ASSY...
Страница 26: ...26 CONDUX TESMEC INC HYDRAULIC DRIVE REEL STAND ASSY...
Страница 28: ...28 CONDUX TESMEC INC HYD HAND PUMP MANIFOLD...
Страница 30: ...30 CONDUX TESMEC INC HYD HAND PUMP MANIFOLD...
Страница 32: ...32 CONDUX TESMEC INC HYDRAULIC CONTROL VALVE...
Страница 34: ...34 CONDUX TESMEC INC CHAIN GUARD...
Страница 36: ...36 CONDUX TESMEC INC HOSE RACK GROUND ATTACHMENT...
Страница 40: ...40 NOTES...
Страница 41: ...41 NOTES...